Thank you for choosing the thermostat.RT110
Designed for simplicity and eciency, this thermostat
provides smooth temperature control tailored to your
comfort needs. Its intuitive operation, combined with
quick responsiveness and reliable performance, makes it
easy for anyone to use.
To enhance both safety and comfort, the thermostat
includes Valve Protection (VP) and Proportional Control
(PWM) functions. These features safeguard system
components while helping to maintain an optimal and
consistent indoor climate.
Introduction
Technical Specications
Power supply
230V / 50Hz
Temperature scale
°C
Temperature adjustment
range
5°C up to 30,0°C
Temperature setting
resolution
Continue
Temperature measurement
accuracy
Max. +/-1°C to 25°C
Operating temperature
0°C – 50°C
Storage temperature
-20°C up to 60°C
TerminalFunction
LLive input
NNeutral input
COMCommon terminal – Voltage-free
NONormally open – Voltage-free
NCNormally closed – Voltage-free
Dimensions
o
C
30
5
25
10
20
15
B
C
A
Dimensions (mm)
ABC
75 7927
Warning - Please read this manual before
installation or use.
To ensure safety and optimal performance, the
thermostat must be used in accordance with all applicable
regulations. This device is designed exclusively for indoor
use and must not be installed in environments exposed
to extreme temperatures or other harsh conditions. Keep
the thermostat completely dry; incorrect installation
may cause damage or malfunction. Always disconnect
the device before cleaning, and use only a dry cloth.
For safe operation, position the thermostat at a suitable
height to allow easy access. As the maximum operating
temperature of the device is 50°C, avoid placing it in areas
where this limit may be exceeded to prevent overheating.
Following these guidelines will ensure long-term
reliability and safety of the thermostat.
Safety Information
This product complies with the essential requirements and
other relevant provisions of Directives: GPSR 2023/988/EU, EMC
2014/30/EU, LVD 2014/35/EU and RoHS 2017/2102/EU.
The full text of the EU Declaration of Conformity is available at the
following internet address: www.saluslegal.com
Product compliance
The RT110 is equipped with NO (normally open) and NC
(normally closed) contacts, making it compatible with
heating systems (such as boilers and heat pumps). Its
voltage-free contacts allow easy integration with a wide
range of equipment, ensuring simple and reliable operation.
Compatibility
Terminal Description
When wiring, make sure that each terminal is connected
according to its designated function. Always follow
recognized standards to ensure a safe and correct installation.
Mount the thermostat vertically on the wall of the room.
Position it at least 1.5 m above the oor in an accessible and
well-ventilated location, so that it can accurately measure
the room temperature.
Proper positioning
1.5m
Box Content
RT110
Thermostat
2 x
Screws
2 x Wall Mounting
Achors
Quick
Guide
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS
Controls plc reserves the right to change specications, design
and materials of products listed in this brochure without prior
notice.
www.saluscontrols.com
04/2026
DE / NL: [email protected]
DK: Support@salus-controls.dk
RT110
ELECTRONIC DIAL
THERMOSTAT
QUICK GUIDE
MANUAL
EN
Manufacturer: SALUS Controls plc
Units 8-10, Northeld Business Park,Forge Way,
Parkgate Rotherham, S60 1SD, United Kingdom
Importer: Salus Controls European Distribution sp.z o.o.
ul. Szamocka 8, piętro 6., 01 748 Warszawa, Poland

90
o
Please check that the
rotary knob is in the
correct position.
Wall mounting procedureReinstall the Cover
Wiring Procedure – 230 V Connection
NCC
T
H
NO
COM
N
N
L
L
11
2
3
4
2
34
TERMINALS
NONC
N
OM
C
JUMPERS
Set the Jumpers According to Your Needs.
Adjust the jumpers according to your preferences by aligning them with the desired operating
mode or function.
Check the Position of the Rotary Knob
Before replacing the cover, make sure the
internal rotary knob is correctly aligned, as
shown in the illustration.
This step is important to ensure the knob
functions correctly once reassembled.
After correctly setting the jumpers, carry out the wiring
step by step, connecting each conductor to its designated
terminal. Check the markings (L, N, COM, NO, NC) carefully,
as any error may cause malfunction, reduced performance, or
damage to the device. Ensure the power supply is switched
o while making adjustments, then verify the conguration
against the wiring diagram before restoring power to ensure
a safe, compliant installation.
Power supply: 230 V / 50 Hz
Maximum load: 3(1) A (valve actuators or other electrical devices)
NO terminal – Normal Open Terminal (Voltage-free contact)
NC terminal – Normal Closed Terminal (Voltage-free contact)
OFF
PROPORTIONAL CONTROL (PWM)-DISABLED
The thermostat switches the heating fully on or
o based on the set temperature, with a small
tolerance of ±0.5 °C.
VALVE PROTECTION (VP) – DISABLED
The thermostat does not operate in weekly
mode. If the heating system is not used for an
extended period, the valve may seize or become
stuck.
ON
VALVE PROTECTION (VP) – ENABLED
The thermostat automatically activates the valve
for 5 minutes once a week to prevent it from
seizing during periods of inactivity.
PROPORTIONAL CONTROL (PWM) – ENABLED
The thermostat controls the heating in 5-minute
cycles, switching on and o as needed to
maintain a stable and comfortable temperature.
L
Jumpers and wiring
Once the thermostat is open, check the location of the
terminals and jumpers (represented in the image below).
Product specificaties
| Merk: | Salus |
| Categorie: | Thermostaat |
| Model: | RT110 |
Heb je hulp nodig?
Als je hulp nodig hebt met Salus RT110 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden