Salus CB500X Handleiding
Salus Thermostaat CB500X
Bekijk gratis de handleiding van Salus CB500X (2 pagina’s), behorend tot de categorie Thermostaat. Deze gids werd als nuttig beoordeeld door 2 mensen. Heb je een vraag over Salus CB500X of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

www.saluscontrols.com
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
MANUFACTURER:
SALUS Controls, Units 8-10, Northeld
Business Park, Forge Way, Parkgate
Rotherham, S60 1SD, United Kingdom
IMPORTER:
Salus Controls European Distribution sp.z o.o.
ul. Szamocka 8, piętro 6., 01-748
Warszawa Poland
05 / 2026
Introduction
Control box description
Technical Information
The CB500X extension module control box is an element of the underoor heating / cooling control system.
The control box allows you to control 5 dierent zones. Number of controlled zones can be increased up to 15
zones by connecting CB500X extension modules to the CB500 unit which is equipped with a module system
that controls the source of heating and cooling. Each individual zone can be operated by one thermostat.
Thermostat which require 230V power supply has to be powered directly from control box. The spring clamps
provide quick and convenient wiring connections. The control box is designed to work with NC
(normally-closed) type actuators. It is recommended to mount it on a surface or on a DIN rail.
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU
Directives: GPSR 2023/988/EU, EMC 2014/30/EU, LVD 2014/35/EU and RoHS 2017/2102/EU.
The full text of the EU Declaration of Conformity is available at the following internet address:
www.saluslegal.com
Use in accordance with current national and EU regulations. Device is intended for indoor use only in dry
conditions. Product for indoor use only. Installation must be carried out by a qualied person in accordance
to current national and EU regulations.
Before attempting to setup and install, make sure that the devices is not connected to any power source.
Installation must be carried out by a qualied person. Incorrect installation may cause damage to the
devices. The CB500X should not be installed in areas where it may be exposed to water or damp conditions.
Safety information
Manual
Control box ext
Model: CB500X
1. Care fusetridg 5 x 20 mm T2A
2. Powsuly er pp
*
3. NSB (Night Set Back reduction) function
4. Actuators output connections (AC 230V)
5. Thmostats input conneconserti
6. CB500X extension input
Power Supply230 V AC
Total Load Max1 A
OutputsActuators (AC 230V)
Dimensions [mm]270 x 110 x 55
4
6
6
6
5
3
21
1. Fuse
Note: Replacement of the fuse to be carried out only when the control box is disconnected
from power supply (230 V ~).
*WARNING!DO NOT connect power supply to the CB500X power supply input when it is connected together with CB500. CB500X power supply input have to be used only when control box extension works
as standalone ice.dev
Main fuse is located under the housing cover next to power supply terminals and secures the control box
and the devices connected to it. Use ceramic tube slow blow 250 V ROHS fuses (5x20 mm) with nominal
max current 2A. To replace fuse remove the fuse holder with a at screwdriver and pull out the fuse.
2. Power Supply
3. NSB (ht SBack reduction) functionNiget
The NSB (Night Set Back) function enables you to automatically reduce the setpoint temperature on
non-programmable thermostats via a programmable thermostat connected to the same control box or an
extension module. NSB function changes comfort to economic setpoint temperatures for each thermostat
individually. The programmable thermostat, e.g. installed in the living room, sends a signal to the
non-programmable thermostats through a control box (by wires). Then, the non-programmable thermostats
automatically reduce the setpoint temperature according to the value set on them.
The NSB terminal is marked with the clock icon – all NSB terminals are connected together within the control
box. The NSB function works only in 4-wire installations (see connection diagrams).
230 V AC
L
N
4. Actuators connection
Actuators wires should be plugged into the spring clamps of the respective zones. Maximum current load
for each zone is designed to handle up to 6 actuators with a power of 2W each. With more actuators in
one zone, an additional relay should be used to make sure that actuators output will be not overloaded.
Example based on T30NC 230 V actuators
Depends on the
thermostaating/cooling t he
state - 230 V AC may appear
on the actuators output.
Powerpp suly for control box is 230 V ~ 50Hz.
Three wire installation should be made in
accordance with the current applicable
3
The red LED will illuminate indicating
that the control box is connected to the
power supply.
Note:
Product specificaties
| Merk: | Salus |
| Categorie: | Thermostaat |
| Model: | CB500X |
Heb je hulp nodig?
Als je hulp nodig hebt met Salus CB500X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermostaat Salus
15 September 2026
2 September 2026
1 September 2026
5 Augustus 2025
4 Augustus 2025
4 Augustus 2025
28 Juli 2025
28 Juli 2025
28 Juli 2025
28 Juli 2025
Handleiding Thermostaat
Nieuwste handleidingen voor Thermostaat
15 September 2026
14 September 2026
9 September 2026
4 September 2026
3 September 2026
2 September 2026
5 Augustus 2026
14 Juli 2026
12 Juli 2026
10 Juli 2026