Installation
How to install the pipe/cylinder thermostatIntroduction
The AT10 contact thermostat is a mechanical thermostat
that can be easily installed on a pipe surface or by placing
the capillary in a sleeve, like a hot water tank. It allows you
to control the temperature of hot water (DHW) or central
heating. It can be used to switch connected devices on or o
depending on the measured temperature. These can include:
pumps, switching valves, or boilers.
Product compliance
This product complies with the essential requirements and other
relevant provisions of Directives GPSR 2023/988/EU, LVD 2014/35/
EU, SVHC 251 and RoHS 2017/2102/EU. The full text of the EU
Declaration of Conformity is available at the following address:
www.saluslegal.com
2405-2480MHz, <14dBm
Safety information
Use in accordance with national and European regulations.
Use the device for its intended purpose and do not allow it
to get wet. Product intended for indoor use only. Installation
must be carried out by a qualied person in accordance with
national and European regulations.
SALUS Controls is a member of the Computime Group. In
accordance with its policy of continuous product improvement,
SALUS Controls plc reserves the right to modify the technical
specications, design, and materials of the products featured in
this brochure without prior notice.
EN
AT10, AT10F
QUICK GUIDE
PIPE/CYLINDER THERMOSTAT
Manufacturer: SALUS Controls plc
Units 8-10, Northeld Business Park, Forge Way,
Parkgate Rotherham, S60 1SD, United Kingdom
Importer: Salus Controls European Distribution sp.z o.o.
ul. Szamocka 8, piętro 6., 01 748 Warszawa, Poland
www.saluscontrols.com
04/2026
MANUAL
AT10: To install, press the thermostat rmly onto the heating pipe and secure it with
the elastic band provided so that the thermostat is in direct contact with the pipe
(remove any insulation from the mounting area before securing the sensor). Excess
band can be cut o.
AT10F: Secure the thermostat to a at surface using screws. Then insert the mea-
suring element (capillary tube) into a sleeve, for example, in the hot water tank.
Changing the set temperature
To set the temperature, pull the knob toward you to release it. Then turn the knob
to the position that indicates the desired temperature. To save this setting, gently
push the knob inward until you hear a click.
Technical information
Terminals description
Power supply
Maximum load
Output signal
Temperature control range
Dimensions (mm)
230 V AC
16 (4) A
1/C/2 (NO/COM/NC)
30-90 °C
105 x 50 x 45 AT10F
capillary length: 1000 mm
capillary diameter: 1.3mm
temperature bulb diameter: 6.5mm
Remove the button (1) and loosen
the large plastic screw (2).
Remove the housing cover.
Connect the conductors according to
the diagram shown.
TerminalDescription
C
1
2
Common contact
NO – normally open contact
NC – normally closed contact
Earthing
1. Protection against overheating of underoor heating – if the set temperature
is exceeded, terminals C-1 open.
2. Domestic hot water tank (DHW) charging – if the temperature in the tank falls
below the set value, terminals C-1 are closed.
BOILER/
HOT WATER TANK
Product specificaties
| Merk: | Salus |
| Categorie: | Thermostaat |
| Model: | AT10F |
Heb je hulp nodig?
Als je hulp nodig hebt met Salus AT10F stel dan hieronder een vraag en andere gebruikers zullen je antwoorden