Vaxcel Bedford T0732 Handleiding
Pagina's 15 Verlichting
Bekijk de handleiding van Vaxcel Bedford T0732 gratis online of download de PDF. Deze handleiding is 1 keer bekeken. Vraag over dit model? Stel een vraag

ASSEMBLY AND INSTALLATION
INSTRUCTIONS
T0732 / T0733
Maximum Wattage: 60W Bulb
Working Temperature: - 22°F~113°F
1. Read all instructions carefully before installation and
operation.
2. If you are not familiar with state and local electrical codes,
it is recommended that you consult with a qualified
electrician.
3. Before installation, shut off power at the main fuse or
circuit breaker box. Be aware that simply turning off the
wall switch is not sufficient to prevent an electrical shock.
4. This fixture requires a 120V AC, 60 Hz power source.
5. Do not attempt to take the lantern apart; there are no
serviceable parts inside.
6. To avoid sensor damage by lightning or electrical surge,
make sure the ground wire is securely connected.
7. For general safety and to avoid any possible damage to
the sensor, be sure the power is switched "off" before
replacing the bulb.
8. Compatible with most LED dimmable bulbs.
Hardware Package (included)
:
Important to Know
Features
W
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. Read
and save these instructions.
Page 1 / 5
1. Energy saving fixture.
2. When in manual override mode, use wall switch
to keep the light ON till dawn.
Mounting Screw (B)
Wire Connector (C)Bolt Nut (D)
Mounting Plate Unit (A)
Rubber Pad (E)
Wire Connector (C)
House Ground Wire
Outlet Box
Mounting Screw (B)
Green Ground Screw
Fixture Mounting Screw
Mounting Plate Unit (A)
Fixture Wire
Backplate
Rubber Pad (E)
Bolt Nut (D)
Fixture Ground Wire
Max. 60W Type A Bulb
(not included)
Finial
Rubber Pad-A
Threaded PipeCover
WARNING: Turn off the main power at circuit breaker before installing fixture.
231011

Turn on the power at fuse or circuit box.
Turn off the power at fuse or circuit box
Installation Steps
The Position of Control Panel
Page 2 / 5
1. Unscrew the two bolt nuts (D), remove the two rubber pads (E) and the mounting plate unit (A) from the backplate.
2. Attach the mounting plate unit (A) to the outlet box by using two mounting screws (B). Adjust the length of the
preinstalled fixture mounting screws if necessary.
Note: Make sure that the fixture mounting screws are lined up horizontally to make the fixture level.
3. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:
•
Connect the hot wire (black insulation) from the fixture to the black wire from the power source.
•
Connect the neutral wire (white insulation) from the fixture to the white wire from the power source.
•
Attach the fixture ground wire (bare wire) to the mounting plate unit (A) with the green ground screw, then
depending on local code, connect it to the house ground wire with the wire connector (C).
Carefully put all of the wires back into the outlet box.
4. Attach the backplate of the fixture to the mounting plate unit (A) by inserting fixture mounting screws into set holes
on the backplate, then secure it with two rubber pads (E) and two bolt nuts (D).
Note: With silicone caulk compound, caulk completely around where the backplate meets with the wall
surface to prevent water from seeping into the outlet box.
5. Insert the the cover and the rubber pad-A through the threaded pipe, then secure them with the finial.
6. Install the bulb (not included). Check relamping label at socket area or packaging for maximum wattage allowed.
Sensor
Step 1: Rotate the sensor clockwise or counter-clockwise
at maximum 90 degree to access the adjustable
knobs. (See Fig.1)
Step 2: Adjust time and sensitivity, choose the mode you
want by turning the knob. (See Fig.2 and Fig.A).
Step 3: Restore the sensor to original position by rotating
to the opposite direction. (See Fig.3)
Fig.A
Time
Auto
Off
Mode
Sens
TestPC
"Time" Knob
"Mode" Knob
"Sens" Knob
View Fig.A
Fig.2
Adjustable
Knob
Time
Auto
Off
ModeSens
TestPC
Fig.1
Sensor
Fig.3
231011

Function and Operation
MODES OF OPERATION
Page 3 / 5
Choose a mode by turning the rotary knob. The light will turn on immediately when power is applied. Wait for 30
seconds to allow the sensor to warm up.
1. Test MODE (daytime and nighttime operation.)
● The light will turn on when motion is detected, and stay on as long as the motion continues. The light will turn to
low-level brightness (30%) after 5 seconds when motion is no longer detected.
2. Off MODE (nightime operation only)
● At dusk, the light stays off and will turn to high-level brightness (full brightness) when motion is detected, and stay
on as long as the motion continues. When the motion stops, the light will stay on for the predetermined time set
(5~180 seconds), then the light will turn off.
3. Auto MODE (nighttime operation only)
● At dusk, the light will turn on when motion is detected, and stay on as long as the motion continues. When the
motion stops, the light will remain on for the predetermined time set (5~180 seconds) and then turn to low-level
brightness (30%).
● The light will turn off automatically at dawn.
4. PC MODE (nighttime operation only)
● The light will turn on automatically at dusk and turn off at dawn.
Auto Mode
Off Mode
Manual
Override
Manual Override Operation Diagram
Turn wall switch OFF-ON
in 0.5~3 Seconds
Turn wall switch OFF-ON
in 0.5~3 Seconds
Fig. 4
5.Manual Override MODE (nighttime operation only)
●
To shift to the manual override mode, set the switch to "Auto" or
"Off" mode. Turn the wall switch "OFF" and "ON" within 3 seconds.
The light will remain on until dawn. To restore to the "Auto" or "Off"
mode, turn the wall switch "OFF" and "ON" within 3 seconds.
(See Fig.4)
●
The light will last for one night only and turn off automatically at
dawn.
Note: 1.Always keep the wall switch in the "ON" position
(including the daytime).
2. Please notice the warm up time is 30 seconds, any
operations are invalid during this time.
Customization Options
Shut-off Delay
Fig. 5
(View from back of sensor lens)
1.The Shut-off delay is the length of time that the light will stay on
after motion stops.
2. The Shut-off delay can be adjusted by using the "Time" knob when
the knob is set in "Off" or "Auto" mode. (See Fig.5)
3.The range of shut-off delay is 5 seconds to 3 minutes.
4.Rotate the knob clockwise for increasing the shut-off delay.
5.Rotate the knob counterclockwise for decreasing the shut-off delay.
Time
Auto
Mode
Sens
Test
Off
PC
231011
Product specificaties
| Merk: | Vaxcel |
| Categorie: | Verlichting |
| Model: | Bedford T0732 |
Heb je hulp nodig?
Als je hulp nodig hebt met Vaxcel Bedford T0732 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden