Bekijk gratis de handleiding van Crestron CLW-DELVEX-P (2 pagina’s), behorend tot de categorie Dimmer. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.6 sterren uit 1.5 reviews. Heb je een vraag over Crestron CLW-DELVEX-P of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

CLW-DELVEX-E/CLW-DELVEX-P
Cameo
®
Wireless In-Wall ELV Dimmer, 120 V
Installation & Operation Guide
Description
The Crestron
®
CLW-DELVEX-E and CLW-DELVEX-P are Cameo
®
in-wall ELV dimmers
designed for dimming electronic low-voltage lighting, supporting lighting loads such as
tungsten-halogen, incandescent, and dimmable LED replacement lamps. Versatile and
affordable, the CLW-DELVEX-E and CLW-DELVEX-P feature eld-replaceable, engravable
buttons and can be congured with various button layouts and designer colors.
The CLW-DELVEX-E and CLW-DELVEX-P are functionally identical. For simplicity within
this guide, the term “CLW-DELVEX-E/P” is used except where noted.
CLW-DELVEX-E/P Specications
SPECIFICATIONS DETAILS
Load Rating
Load Type
Maximum Load
Minimum Load
Electronic low-voltage, LED, incandescent,
tungsten-halogen, electronic CFL, 2-wire uorescent
ballast
500 VA/watts
10 Watts
Power Requirements 120 Vac, 50/60 Hz, line power
A dedicated neutral wire is required.
Enclosure 1-gang mountable in a 3-1/2 inch (89 mm) deep
electrical box;
Requires decorator style faceplate (not included)
Environmental
Temperature
Humidity
32° to 104 °F (0° to 40 °C)
10% to 90% RH (noncondensing)
Additional Resources
Visit the product page on the Crestron website
(www.crestron.com) for additional information
and the latest rmware updates. Use a QR reader
application on your mobile device to scan the QR
image.
CLW-DELVEX-E CLW-DELVEX-P
Important Notes
WARNING: To avoid re, shock, or death, turn off power at the circuit breaker or fuse
and test that power is off before wiring!
WARNING: New installations should be checked for short-circuits prior to installing a
CLW-DELVEX-E/P dimmer. With the power off, close the circuit and then restore power.
If the lights do not work, or a breaker trips, check and correct the wiring or xture (if
necessary). Install the dimmer only when the short is no longer present. The warranty is
void if the dimmer is installed and operated with a shorted load.
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO
OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, A MOTOR-
OPERATED APPLIANCE OR A TRANSFORMER-SUPPLIED APPLIANCE.
ATTENTION: GRADATEURS COMMANDANT UN BALLAST-AFIN DE RÉDUIRE LE
RISQUE DE SURCHAUFFE ET LA POSSIBILITÉ D’ENDOMMAGEMENT À D’AUTRES
MATÉRIELS, NE PAS INSTALLER POUR COMMANDER UNE PRISE, UN APPAREIL
OPÉRÉ DE MOTEUR OU UN APPAREIL ALIMENTÉ PAR UN TRANSFORMATEUR.
NOTE: Observe the following points.
• Codes: Install in accordance with all local and national electrical codes.
• Installation: This product should be installed by a qualied electrician.
• Wiring: Use copper wire only. For supply connections, use wire rated for at least
75 °C.
• Lamp Type: For use with permanently installed incandescent, electronic
low-voltage halogen or LED, tungsten-halogen, or dimmable CFL only.
• Temperature: For use where temperatures are between 32° to 104 °F (0° to 40 °C).
• Electrical Boxes: Devices mount in standard electrical boxes. For easy installation,
Crestron recommends using 3-1/2 in (89 mm) deep electrical boxes. Several
devices can be installed in one electrical box (multigang). This requires derating of
the dimming device. For a smooth appearance, one-piece multigang faceplates
(not included) can be installed.
• Switches: Mechanical 3- or 4-way switches do not work with CLW-DELVEX-E/P
dimmers.
• Spacing: If mounting one device above another, leave at least 4-1/2 in (115 mm)
vertical space between them.
• Low-Voltage Applications: Use with electronic low-voltage transformers only.
• Do not use any magnetic low-voltage transformers.
• Operation of a low-voltage circuit with all lamps inoperative or removed may
result in current ow in excess of normal levels. To avoid transformer overheating
and premature transformer failure, Crestron recommends the following:
> Do not operate low-voltage circuits without operative lamps in place.
> Replace burned-out lamps as quickly as possible.
> Use transformers that incorporate thermal protection to prevent transformer
failure due to overcurrent.
Installation
Install the CLW-DELVEX-E/P dimmer.
1. Turn the power off at the circuit breaker.
2. Wire the device as shown in the following diagrams. Refer to the table that follows for
wire information.
Wire the CLW-DELVEX-P
White (NEU)
Green
(GND)
Red (LOAD)
Black (HOT)
HOT
120 V~
Blue (REM)
To one or more
CLW-SLVU-P
(optional)
Load
Wire the CLW-DELVEX-E
White (NEU)
Green
(GND)
Red (LOAD)
Black (HOT)
HOT
120 V~
Load
CONNECTION WIRE GAUGE WIRE COLOR
HOT 16 AWG Black
NEU 16 AWG White
LOAD 16 AWG Red
REM 16 AWG Blue
GND 16 AWG Green
3. Push all power wires back into the electrical box and fasten the device to the electrical
box with the provided screws.
4. Attach a decorative faceplate.
5. Ensure all buttons, including the air-gap switch and program button, actuate without
sticking.
6. Restore power at the circuit breaker.
Changing the Button Assemblies
The button assembly can be removed and replaced with other button assemblies. To
replace the button assembly:
1. Squeeze the sides of the bezel near the bezel snaps to remove the button assembly.
Squeeze at arrow
points and pull to
remove the button
assembly.
NOTE: Power to the unit and load is removed automatically when the button
assembly is removed.
2. Remove the button from the front of the button assembly.
Gently spread the
frame apart to
remove the
buttons.
3. Insert the new buttons through the front of the bezel and snap them into place. Ensure
that the LED strip is on the left side.
Gently spread the
frame apart to
insert the buttons.
4. Attach the button assembly to the device. Ensure that the LED strip is on the left side.
5. Once power has been restored, press and hold the program button. After 5 seconds,
the LEDs associated with the old button layout begin to ash. Continue to hold the
button and proceed to step 6.
6. While holding the program button, press all of the buttons in the new layout. The
LED next to the pressed button lights.
NOTE: If the rocker switch is installed, press the top and bottom of the rocker.
7. Release the program button to save the settings after all of the buttons have been
pressed.
Step 5:
Press and hold the program button.
Step 7:
Release the program
button to save the settings.
Step 6:
Press each of the
installed buttons
on the device.
NOTE: Changing the button conguration alters the device’s behavior. Refer to
the “Default Button Functions” for details.
Multigang Installations
In multigang installations, several devices are grouped horizontally in one electrical box.
For a smooth appearance, one-piece multigang faceplates (not included) can be installed.
NOTE: When installing into a multigang box, do not fully tighten devices to the box
until the faceplate has been aligned.
The load capacity for each device in the electrical box must be derated. Derating
information is shown in the illustration below.
Derating Information for CLW-DELVEX-E/P Dimmers
500 W 400 W 400 W 250 W 400 W400 W
Operation
NOTE: Before using the CLW-DELVEX-E/P, ensure the device is using the
latest rmware. Check for the latest rmware for the CLW-DELVEX-E/P at
www.crestron.com/rmware. Load the rmware onto the device using Crestron
Toolbox™ software.
NOTE: The device may be warm during operation. This is normal.
Basic Operation
The CLW-DELVEX-E/P is shipped with a rocker switch already installed. In this
conguration, the unit functions as shown below.
NOTE: Operation described in this guide assumes the CLW-DELVEX-E/P is operating
in Local mode (without the use of a control system). The device can also operate in
Remote mode, in which button behavior is dictated entirely by the control system
program.
The LEDs indicate
the load level.
When all loads are
off, the top LED
remains dimly lit to
act as a night light.
Press to turn the load
on. Press and hold to
raise the light level.
Press to turn the load
off. Press and hold to
lower the light level.

Disconnecting Power
Power to the dimmer and load can be disconnected by pushing on the air-gap switch.
Push here to open
the air-gap switch.
Air-Gap Switch in the
Open Position
NOTE: If the dimmer remains powered after the air-gap is opened, the HOT and DIM
terminals have been connected in reverse. Turn off power at the circuit breaker or fuse
and adjust the connections.
NOTE: Power to the load is automatically disconnected when the button assembly
is removed. For instructions on removing the button assembly, refer to “Changing the
Button Assemblies.”
Setting Preset Levels
The CLW-DELVEX-E/P can recall and store up to three presets depending on the installed
button conguration.
Set a preset level.
1. Adjust the light level to the desired level.
2. Enter Programming mode by quickly pressing the program button as shown below.
Buttons that are capable of storing a preset will ash their LEDs.
NOTE: Programming mode is disabled when the load is off.
3. Press and hold the desired preset button until the LED blinks (approximately two
seconds). Release the button to store the new level.
4. If a button is not pressed, the device exits Programming mode after approximately
ve seconds.
Preset 1
Preset 2
Preset 3
Off
Step 3:
Hold the button to
store a new level.
Step 2:
Quickly press the program
button. LEDs ash to
indicate the buttons that can
be programmed.
NOTE: A delayed off can be added via control system programming.
Default Button Functions
The gures below illustrate the default functions available for each physical button
conguration and press or hold actuation sequence.
Single Button Press
Preset 1
Off
Off
Preset 1
Preset 1
Preset 1
Preset 1
Preset 1
Preset 2
Off
Raise
Raise
Lower
Lower
Preset 1
Toggle
Preset 1
Toggle
Off
Double Button Press (Press Twice within 1/2 Second)
Full On
Full Off
Full On Full On
Full On
Full On
Full On
Full On
Full On
Full On
Full Off
Full Off
Full Off
Single Button Press and Hold (Hold for more than 1/2 second)
Raise
Lower
Raise Raise
Raise
Raise Raise
Lower Lower Lower Lower Lower
Wireless Communications
The device connects to the Crestron network via the inNET EX
®
communications protocol.
Use the procedures outlined below to join or leave an inNET EX network and to verify
communications between the device and the control system.
Joining an inNET EX Network
Before a device can be used in a lighting system, it must rst join an inNET EX network by
being acquired by an inNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inNET EX gateway into Acquire mode from the unit itself or from Crestron
Toolbox, as described in its manual at www.crestron.com/manuals.
NOTE: In an environment where multiple gateways are installed, only one gateway
should be in Acquire mode at any time.
2. Place the device into Acquire mode.
a. Tap the top button three times, and then press and hold it down (tap-tap-tap-
press+hold) until the top LEDs on the device ash once (this can take up to 10
seconds).
b. Release the button to start the acquire process. The top LED ashes slowly to
show that the device is actively scanning the inNET EX network.
• The top two LEDs turn on for 5 seconds to show that the device has been
successfully acquired to the inNET EX network.
• The top LED ashes quickly to indicate that the device was not successfully
acquired by the inNET EX network. Press the top button to acknowledge failure
to acquire the inNET EX network. Ensure the gateway is in Acquire mode and
within range before attempting the acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer to
the gateway’s manual for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the device into Acquire mode, as described in “Joining
an inNET EX Network” above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the top button three times and then
press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The LED ashes to
indicate the communications status. Refer to the following table for details.
LED COMMUNICATIONS STATUS
Turns on for 5 seconds The device is communicating with the control system.
Flashes three times The device is not communicating with the gateway, but the
gateway is not communicating with the control system.
Flashes twice The device was previously joined to the network but is not
communicating with the gateway.
Flashes once The device is not joined to the network.
Troubleshooting
The following table provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CLW-DELVEX-E/P Troubleshooting
TROUBLE PROBABLE CAUSE(S) CORRECTIVE ACTION
The dimmer does not
function.
The dimmer is not
receiving line power.
Verify that the power
connections are correct
and that the circuit breaker
is closed.
The load is not operational
(e.g., lamps are burned
out).
Verify that the load is
operational and that the air-
gap switch is closed.
The device is in Remote
mode.
Check the program to verify
the operating mode.
The neutral wire is not
connected to the dimmer.
Connect a dedicated
neutral wire to the dimmer.
The dimmer does not dim
to a low level or ickers
when dimmed.
The lamps connected
may be better suited to an
alternate dimming mode.
Switch the dimmer to use
Alternate Dimming mode.
Contact Crestron Technical
support or refer to Online
Help Answer ID 5520.
This product conforms to UL STD 1472; certied to CSA STD C22.2 No. 184.1.
FCC ID: Contains EROCWD6790
Compliance Statement (Part 15.19 )
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received, including interference that may cause undesired
operation.
Warning (Part 15.21)
Changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC’s RF exposure limits for general population / uncontrolled exposure, this transmitter
must be installed to provide a separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
The product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specic information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, Cameo, Crestron Toolbox, and inNET EX are either trademarks or
registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and
the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the
United States and/or other countries. Other trademarks, registered trademarks, and trade names may
be used in this document to refer to either the entities claiming the marks and names or their products.
Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible
for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2017 Crestron Electronics, Inc.
Crestron Electronics, Inc. Installation & Operation Guide - DOC. 7334E
15 Volvo Drive, Rockleigh, NJ 07647 (2033164)
Tel: 888.CRESTRON 11.17
Fax: 201.767.7576 Specications subject to
www.crestron.com change without notice.
Product specificaties
Merk: | Crestron |
Categorie: | Dimmer |
Model: | CLW-DELVEX-P |
Heb je hulp nodig?
Als je hulp nodig hebt met Crestron CLW-DELVEX-P stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Dimmer Crestron
13 Mei 2025
13 Mei 2025
1 April 2025
1 April 2025
11 Maart 2025
11 Maart 2025
11 Maart 2025
11 Maart 2025
11 Maart 2025
11 Maart 2025
Handleiding Dimmer
- Ltech
- Trust
- Eminent
- Jung
- Paladin
- Handson
- DIO
- Grasslin
- Tradim
- Mercury
- Adastra
- Velbus
- Elro
- Bearware
- InterBar
Nieuwste handleidingen voor Dimmer
28 Maart 2025
28 Maart 2025
2 December 2024
1 December 2024
1 December 2024
1 December 2024
1 December 2024
1 December 2024
1 December 2024
1 December 2024