Sussex DBSHS Handleiding

Sussex Kraan DBSHS

Lees hieronder de 📖 handleiding in het Nederlandse voor Sussex DBSHS (8 pagina's) in de categorie Kraan. Deze handleiding was nuttig voor 10 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
AS/NZS 3718:2005
LIC. 20081
-Ensure Maximum bench thickness is (i) 25mm.
-Standard Spindles are supplied pre-installed into basin bodies and do not need to be seperated.
-Handle holes should be between diameter to allow for spindle clearance.(ii) 33mm and 36mm
-The clearance hole for the outlet should be between (iii) 21mm and 23mm.
-In order to install the basin bodies under the bench, temporarily unscrew the top set of the basin body locknuts
(E) and basin body clamping washers (D) and set aside.
-Seperate Handle Assembly (B) prior to install.
-Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2021
-Recommended working water pressure 300 - 500 Kpa. Maximum water temperature is 65°C
-After installation, ensure that tapware functions correctly without leaks.
-Please ensure a copy of the Installation Instructions are left with the end user for future reference.
DBS
DBSHS
Duet
Basin set
Product code
Rough-in:
Plumber note
D
-(A) Basin Outlet.
-(B) Handle Assembly (consisting of B1 - Handle, B2 - Spindle Adapter and B3 - Dress Ring).
-(C) Outlet O-Ring.
-(D) Basin Body Clamping washer.
-(E) Basin Body Locknut.
-(F) Phillips Head Screw.
-(G) Basin Body Assembly
-(H) Tee-piece.
-(I) Outlet Locknut
-(J) Outlet Clamping Washer
Product parts
H
I
J
E
F
G
B1
B
B3
B2
A
C
While we aim to ensure the specifications shown are correct at time of printing, Sussex Taps reserves the right to make modifications without prior notice.
Always use the physical product for accurate measurements. Dimensions are subject to change without notice. All measurements are shown in millimetres.
Copyright © Sussex Taps sussextaps.com.au
Step 1
Measure the bench top thickness and the distance between tap centres. Maximum bench
thickness is 25mm and the maximum distance between tap centres is 220mm.
Step 3
Cut the Tee-piece (H) to the correct size if required and affix Basin Body (G) on either side
using supplied locknuts. If an extension is required, contact the suppliers.
G
H
Step 2
- Loosely connect Tee-piece (H) to the hot/cold Basin Bodies (G)
- Measure distance between the centre of the Basin Bodies (G)
G
H
FIT OFF
G
Step 4
On the top of the counter, screw the Dress Rings (B3) onto the spindle locknuts. Fit the dress
ring and ensure it meets the top surface.
B3
sussextaps.com.au


Product specificaties

Merk: Sussex
Categorie: Kraan
Model: DBSHS

Heb je hulp nodig?

Als je hulp nodig hebt met Sussex DBSHS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Kraan Sussex

Handleiding Kraan

Nieuwste handleidingen voor Kraan