CDN ProAccurate INTP662 Handleiding

CDN Thermometer ProAccurate INTP662

Bekijk gratis de handleiding van CDN ProAccurate INTP662 (5 pagina’s), behorend tot de categorie Thermometer. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 5.0 sterren uit 3.5 reviews. Heb je een vraag over CDN ProAccurate INTP662 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
for non-contact and internal temperatures
•NSF
®
Certified
•1&3secondresponses
•1.5mmthintip
•3.75”(9.53cm)probe
•Infraredfornon-contactsurfacetemperatures
•Thermocoupleprobeforinternaltemperatures
•Maximum,minimumandlockmodesforcontinuous
scanning
•8-beamlasertargetillumination
•Distance:Spot=8:1
•Data-hold
•One-buttonoperation
•BacklitHACCPchecklights
•Batterystatusindication
•Food-safeABSplasticwithBioCote
®
•Stainlesssteelprobe
•Auto-off
•Batteryandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeepingfoodsafe.
TheversatileINTP662isapowerhousekitchentool.
Simplypointtheinfraredguntowardthetargetandpress
thetriggertogetaquickreadingofsurfacetemperatures
orflipdowntherapid-responsethermocoupleprobeto
measureinternaltemperatures.IntegratedHACCPcheck
backlightinginstantlyshowsiftemperaturesarewithin
HACCPguidelinesforsafefoodtemperatures.
Minimum, Maximum and Lock
TheINTP662alsooffersMinimum,Maximum,andLock
modes.Minimummodedisplaysthelowesttemperature
amongmultipletargets.Maximummodedisplaysthe
highesttemperatureamongmultipletargets.WhileLock
modecontinuouslydisplaysthetemperatureforupto
60minutes.Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
Note:Removestickerfromdisplaybeforeuse.Cleanthe
thermometerprobebeforeeachuse.
Important: DO NOT LEAVE THERMOMETER IN HOT OVEN.
HAND WASH AND DRY. DO NOT IMMERSE HOUSING IN
LIQUID.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthat
appearsonthedisplayisshownin .BOLD CAPS
Battery Installation
ReplacebatterywhenLCDbecomesdim.Poweroffthe
unitbeforeinstallingthebatteries.Amalfunctionmay
occurifthepowerisonwhenthebatteryisinstalled.Ifa
malfunctionoccurs,restartthedevice.
1. Removebatterycoverbyslidingitdownalongthe
handle.
2. Installtwo1.5VAAAbatteriesobservingpolarity
shownincompartment.
3. Replacethebatterycoveruntilitclicksshut.
Model: INTP662
ProAccurate
®
Infrared Gun/
Thermocouple Thermometer
Infrared:-76to+662°F/-60to+350°C
Thermocouple:-76to+662°F/-60to+350°C
Operating Instructions
Mode Selection:MINØ Ø ØMAX LOCK °C/°FØEMIS
A. Temperature Scale
ToselecttemperaturereadinginFahrenheitorCelsius:
1. Pressthetriggertoturnthethermometeron.
2. PresstheMODEbuttonfourtimes.The°F or °C
symbolflashesonthedisplay.
3. PresstheSCANbuttontochangethescale.
B. Infrared Thermometer
InfraredisthedefaultmodeoftheINTP662.
Note:TheINTP662isintendedforfoodserviceuse—donotuse
forsafetyrelatedapplications.
1. Infrared Scanning
a. Distance:Spot = 8:1
Forexample,ifthe
surfaceareabeing
measuredis10"in
diameter,thenthethermometermustbewithin
80"ofthetargetforanaccuratereading.
b. Aimtheinfraredlensatthetargetandpress
thetriggertodisplaythesurfacetemperature.
The8-beamlaserlightautomaticallyilluminates
thetarget,specifyingtheapproximate
measurementareaforbettertargeting.
c. The8-beamlaserlightformsacirclethat
definestheareaofmeasure.Makesurethe
circleissmallerthantheareabeingmeasured.
Ifthelaserlightcircleislargerthanthearea
beingmeasured,thereadingwillincludeambient
temperaturesandmakethereadinginaccurate.
d. Measurementcontinuesaslongasthetrigger
ispressed.Thenewestreadingupdatesthe
display.
e. Whenthetriggerisreleased,HOLD appears on
thedisplayandthelastreadingremainsvisible
for15secondsbeforetheunitautomatically
powersoff.
2. Minimum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttononce. flashesonMIN
thedisplay.
c. PressthetriggertoconfirmtheMinimumMode
anddisplaythelowesttemperatureamong
multipletargets. remainsonthedisplay.MIN
d.Thethermometercontinuestodisplaythe
minimumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagainor
theunitpowersoff.
3. Maximum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttontwice. flashesonMAX
thedisplay.
c. PressthetriggertoconfirmtheMaximumMode
anddisplaythehighesttemperatureamong
multipletargets. remainsonthedisplay.MAX
d.Thethermometercontinuestodisplaythe
maximumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagain
ortheunitpowersoff.
4. Lock Mode
Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonthreetimes.LOCK
flashesonthedisplay.
c. PressthetriggertoconfirmtheLockMode.
The°F or °Csymbolflashesonthedisplay.
d. Thethermometercontinuouslydisplaysthe
temperatureforupto60minutesoruntilthe
triggerispressedagain.
5. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.10(10E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecific
materials,pleasecontactCDN.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonfivetimestoenter
EmissivityMode. flashesonthedisplay.95E
c. Pressthetriggertoadjusttheemissivityvalue
in0.01(1E)increments.
d. PresstheMODEbuttonagaintoexit
EmissivityMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
6. Error Messages
TheINTP662incorporatesvisualdiagnostic
messagesasfollows:
a. HI LO or isdisplayedwhenthetemperature
beingmeasuredisoutsidetheinfraredrange
oftheinstrument.
1.)HI indicatesthatthetemperatureishigher
than+662°F/+350°C.
2.)LO indicatesthatthetemperatureis
lowerthan-76°F/–60°C.
b. Allowaminimum30minutesforthe
thermometertostabilizetotheworking/room
temperature.
Distance:Spot(FOV)=8:1
Emissivity=0.1~1,Step.01
WaveLength=8~14µm
CAUT ION: Never point the unit and/or las er toward s
anyone’s eyes. Do not look directly into the laser
beam s permanent eye damage may result. Keep
away from children.
1.)ER2 isdisplayedwhenthethermometeris
exposedtorapidchangesinthe
ambienttemperature.
2.)ER3 isdisplayedwhentheambienttemperature
exceeds-32°F/0°COR+122°F/+50°C.
c. Forallothererrormessagesitisnecessary
toresetthethermometer.
1.)Waitforthethermometertopoweroff.
2.)Removethebatteryandwaitforaminimum
ofoneminute.
3.)Reinstallthebattery(seeBattery Installation).
4.)PresstheTriggertoturnthethermometeron.
5.)Iftheerrormessageremains,pleasecontact
CDNforfurtherassistance.
C. Thermocouple Probe
Important: The probe may be damaged if measurement
temperature is lower than -76°F/-50°C OR higher than
+662°F/+350°C.
1. Flipdowntheprobeuntilfullyextended.
Important: Do not twist the probe or rotate it in wrong
direction. Exceptional stress on probe may cause it to break.
CAUTION:Toavoidelectricshockandthermometerdamage,
donotusethethermocoupleprobetomeasurelivecircuitwhere
voltageexceeding24VACRMSor60VDC.
2. Inserttheprobeatleast1"/2.5cmintothefood.
3. PressthePROBEbuttontocontinuouslydisplay
thetemperatureforupto4minutesbeforetheunit
automaticallypowersoff.Thedisplayflashes.
Note:PressingthePROBEbuttonmayinterruptthelast
infraredHOLDreading.PressthePROBEbuttonagaintoreturn
toinfraredscanning.
4. Wearingaheatresistantglove,fliptheprobeback
intothecasewhenfinished.
CAUTION:ProbemaybeHOTafteruse.Alwayswearaheat
resistantglovetotouchthestainlesssteelprobeduringorjust
aftercooking.Do not touch with bare hands.
5. PressthePROBEbuttonagaintoreturntoinfrared
scanning.
D. HACCP Check
IntegratedHACCPcheckbacklightsinstantlyshowif
temperaturesarewithinHACCPguidelinesforsafe
foodtemperatures.
Note:TheGREENandREDLEDbacklightwillalwaysbelitbefore
poweroff.
1. A LEDbacklightindicatesasafecoolorGREEN
frozenconditionbelow40°F/4°Corasafeholding
temperatureabove140°F/60°C.
3. A LEDbacklightindicatesthatthetemperatureRED
iswithinthe of40toHACCP Danger Zone
140°F/4to60°C.
E. Battery Status
Thethermometerincorporatesvisualbatterystatus
indication:
1. measurementsarepossible Battery OK:
2. Battery Low:replacebatterywithtwo1.5V
AAAAlkalinecells;measurementsarepossible
3. replacebattery; Battery Exhausted:
measurementsarenotpossible
Care of Your Product
•Thesensorlensisthemostdelicatepartofthe
thermometerandshouldbekeptcleanatalltimes.
Takecarewhencleaningthelens.Useonlyasoftcloth
orcottonswabwithwaterorrubbingalcohol.Allowthe
lenstodryfullybeforeusingthethermometer.
•Donotsubmergeanypartofthethermometerinwater.
Wipecleanwithadampcloth.
•Storethethermometeratroomtemperaturebetween
-4to+149°F/20to+65°C.
Precautions
•Disposeofusedbatterypromptlyandkeepawayfrom
children.
•Alwayswearaheatresistantglovetotouchthe
stainlesssteelprobeduringorjustaftercooking.
Do not touch with bare hands.
•Keepthebatteries,stainlesssteelprobeandlaser
awayfromchildren.
•Cleantheprobeanddrythoroughlyafteruse.
•Donotcleanthecasewithabrasiveorcorrosive
compound,whichmayscratchtheplasticandcorrode
theelectroniccircuits.
•Donotsubjecttheunittoexcessiveforceshock,
dust,temperatureorhumidity,whichmayresultin
malfunction,shorterelectroniclifespan,damaged
batteryanddistortedparts.
•Donottamperwiththeunit’sinternalcomponents.
Doingsowillinvalidatethewarrantyontheunit
andmaycauseunnecessarybatterydamageand
•Donotsubjecttheunittoexcessiveexposuretodirect
sunlight.The unit is not waterproof—donotimmerse
itintowaterorexposetoheavyrain.
•Toavoiddeformation,donotplacetheunitinextreme
temperatures.Neverburntheprobedirectlyover
thefire.Donotusetheprobewhenthetemperature
isabove662°F/350°C.Doingsowilldeteriorate
theprobe.
•Donotusethethermometerinamicrowaveoven.
•Alwaysreadtheusersmanualthoroughlybefore
operating.
EMC/RFI
Readingsmaybeaffectediftheunitisoperatedwithinaradio
frequency electromagnetic field strength of approximately
3voltspermeter,buttheperformanceoftheinstrumentwill
notbepermanentlyaffected.


Product specificaties

Merk: CDN
Categorie: Thermometer
Model: ProAccurate INTP662