CDN ProAccurate INTP662 Handleiding
CDN
Thermometer
ProAccurate INTP662
Bekijk gratis de handleiding van CDN ProAccurate INTP662 (5 pagina’s), behorend tot de categorie Thermometer. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 5.0 sterren uit 3.5 reviews. Heb je een vraag over CDN ProAccurate INTP662 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/5

for non-contact and internal temperatures
•NSF
®
Certified
•1&3secondresponses
•1.5mmthintip
•3.75”(9.53cm)probe
•Infraredfornon-contactsurfacetemperatures
•Thermocoupleprobeforinternaltemperatures
•Dualfunction
•Maximum,minimumandlockmodesforcontinuous
scanning
•8-beamlasertargetillumination
•Distance:Spot=8:1
•Data-hold
•One-buttonoperation
•BacklitHACCPchecklights
•Batterystatusindication
•Food-safeABSplasticwithBioCote
®
•Stainlesssteelprobe
•Auto-off
•Batteryandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeepingfoodsafe.
TheversatileINTP662isapowerhousekitchentool.
Simplypointtheinfraredguntowardthetargetandpress
thetriggertogetaquickreadingofsurfacetemperatures
orflipdowntherapid-responsethermocoupleprobeto
measureinternaltemperatures.IntegratedHACCPcheck
backlightinginstantlyshowsiftemperaturesarewithin
HACCPguidelinesforsafefoodtemperatures.
Minimum, Maximum and Lock
TheINTP662alsooffersMinimum,Maximum,andLock
modes.Minimummodedisplaysthelowesttemperature
amongmultipletargets.Maximummodedisplaysthe
highesttemperatureamongmultipletargets.WhileLock
modecontinuouslydisplaysthetemperatureforupto
60minutes.Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
Note:Removestickerfromdisplaybeforeuse.Cleanthe
thermometerprobebeforeeachuse.
Important: DO NOT LEAVE THERMOMETER IN HOT OVEN.
HAND WASH AND DRY. DO NOT IMMERSE HOUSING IN
LIQUID.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthat
appearsonthedisplayisshownin .BOLD CAPS
Battery Installation
ReplacebatterywhenLCDbecomesdim.Poweroffthe
unitbeforeinstallingthebatteries.Amalfunctionmay
occurifthepowerisonwhenthebatteryisinstalled.Ifa
malfunctionoccurs,restartthedevice.
1. Removebatterycoverbyslidingitdownalongthe
handle.
2. Installtwo1.5VAAAbatteriesobservingpolarity
shownincompartment.
3. Replacethebatterycoveruntilitclicksshut.
Model: INTP662
ProAccurate
®
Infrared Gun/
Thermocouple Thermometer
Infrared:-76to+662°F/-60to+350°C
Thermocouple:-76to+662°F/-60to+350°C

Operating Instructions
Mode Selection:MINØ Ø ØMAX LOCK °C/°FØEMIS
A. Temperature Scale
ToselecttemperaturereadinginFahrenheitorCelsius:
1. Pressthetriggertoturnthethermometeron.
2. PresstheMODEbuttonfourtimes.The°F or °C
symbolflashesonthedisplay.
3. PresstheSCANbuttontochangethescale.
B. Infrared Thermometer
InfraredisthedefaultmodeoftheINTP662.
Note:TheINTP662isintendedforfoodserviceuse—donotuse
forsafetyrelatedapplications.
1. Infrared Scanning
a. Distance:Spot = 8:1
Forexample,ifthe
surfaceareabeing
measuredis10"in
diameter,thenthethermometermustbewithin
80"ofthetargetforanaccuratereading.
b. Aimtheinfraredlensatthetargetandpress
thetriggertodisplaythesurfacetemperature.
The8-beamlaserlightautomaticallyilluminates
thetarget,specifyingtheapproximate
measurementareaforbettertargeting.
c. The8-beamlaserlightformsacirclethat
definestheareaofmeasure.Makesurethe
circleissmallerthantheareabeingmeasured.
Ifthelaserlightcircleislargerthanthearea
beingmeasured,thereadingwillincludeambient
temperaturesandmakethereadinginaccurate.
d. Measurementcontinuesaslongasthetrigger
ispressed.Thenewestreadingupdatesthe
display.
e. Whenthetriggerisreleased,HOLD appears on
thedisplayandthelastreadingremainsvisible
for15secondsbeforetheunitautomatically
powersoff.
2. Minimum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttononce. flashesonMIN
thedisplay.
c. PressthetriggertoconfirmtheMinimumMode
anddisplaythelowesttemperatureamong
multipletargets. remainsonthedisplay.MIN
d.Thethermometercontinuestodisplaythe
minimumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagainor
theunitpowersoff.
3. Maximum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttontwice. flashesonMAX
thedisplay.
c. PressthetriggertoconfirmtheMaximumMode
anddisplaythehighesttemperatureamong
multipletargets. remainsonthedisplay.MAX
d.Thethermometercontinuestodisplaythe
maximumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagain
ortheunitpowersoff.
4. Lock Mode
Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonthreetimes.LOCK
flashesonthedisplay.
c. PressthetriggertoconfirmtheLockMode.
The°F or °Csymbolflashesonthedisplay.
d. Thethermometercontinuouslydisplaysthe
temperatureforupto60minutesoruntilthe
triggerispressedagain.
5. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.10(10E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecific
materials,pleasecontactCDN.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonfivetimestoenter
EmissivityMode. flashesonthedisplay.95E
c. Pressthetriggertoadjusttheemissivityvalue
in0.01(1E)increments.
d. PresstheMODEbuttonagaintoexit
EmissivityMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
6. Error Messages
TheINTP662incorporatesvisualdiagnostic
messagesasfollows:
a. HI LO or isdisplayedwhenthetemperature
beingmeasuredisoutsidetheinfraredrange
oftheinstrument.
1.)HI indicatesthatthetemperatureishigher
than+662°F/+350°C.
2.)LO indicatesthatthetemperatureis
lowerthan-76°F/–60°C.
b. Allowaminimum30minutesforthe
thermometertostabilizetotheworking/room
temperature.
Distance:Spot(FOV)=8:1
Emissivity=0.1~1,Step.01
WaveLength=8~14µm
CAUT ION: Never point the unit and/or las er toward s
anyone’s eyes. Do not look directly into the laser
beam s — permanent eye damage may result. Keep
away from children.

1.)ER2 isdisplayedwhenthethermometeris
exposedtorapidchangesinthe
ambienttemperature.
2.)ER3 isdisplayedwhentheambienttemperature
exceeds-32°F/0°COR+122°F/+50°C.
c. Forallothererrormessagesitisnecessary
toresetthethermometer.
1.)Waitforthethermometertopoweroff.
2.)Removethebatteryandwaitforaminimum
ofoneminute.
3.)Reinstallthebattery(seeBattery Installation).
4.)PresstheTriggertoturnthethermometeron.
5.)Iftheerrormessageremains,pleasecontact
CDNforfurtherassistance.
C. Thermocouple Probe
Important: The probe may be damaged if measurement
temperature is lower than -76°F/-50°C OR higher than
+662°F/+350°C.
1. Flipdowntheprobeuntilfullyextended.
Important: Do not twist the probe or rotate it in wrong
direction. Exceptional stress on probe may cause it to break.
CAUTION:Toavoidelectricshockandthermometerdamage,
donotusethethermocoupleprobetomeasurelivecircuitwhere
voltageexceeding24VACRMSor60VDC.
2. Inserttheprobeatleast1"/2.5cmintothefood.
3. PressthePROBEbuttontocontinuouslydisplay
thetemperatureforupto4minutesbeforetheunit
automaticallypowersoff.Thedisplayflashes.
Note:PressingthePROBEbuttonmayinterruptthelast
infraredHOLDreading.PressthePROBEbuttonagaintoreturn
toinfraredscanning.
4. Wearingaheatresistantglove,fliptheprobeback
intothecasewhenfinished.
CAUTION:ProbemaybeHOTafteruse.Alwayswearaheat
resistantglovetotouchthestainlesssteelprobeduringorjust
aftercooking.Do not touch with bare hands.
5. PressthePROBEbuttonagaintoreturntoinfrared
scanning.
D. HACCP Check
IntegratedHACCPcheckbacklightsinstantlyshowif
temperaturesarewithinHACCPguidelinesforsafe
foodtemperatures.
Note:TheGREENandREDLEDbacklightwillalwaysbelitbefore
poweroff.
1. A LEDbacklightindicatesasafecoolorGREEN
frozenconditionbelow40°F/4°Corasafeholding
temperatureabove140°F/60°C.
3. A LEDbacklightindicatesthatthetemperatureRED
iswithinthe of40toHACCP Danger Zone
140°F/4to60°C.
E. Battery Status
Thethermometerincorporatesvisualbatterystatus
indication:
1. measurementsarepossible Battery OK:
2. Battery Low:replacebatterywithtwo1.5V
AAAAlkalinecells;measurementsarepossible
3. replacebattery; Battery Exhausted:
measurementsarenotpossible
Care of Your Product
•Thesensorlensisthemostdelicatepartofthe
thermometerandshouldbekeptcleanatalltimes.
Takecarewhencleaningthelens.Useonlyasoftcloth
orcottonswabwithwaterorrubbingalcohol.Allowthe
lenstodryfullybeforeusingthethermometer.
•Donotsubmergeanypartofthethermometerinwater.
Wipecleanwithadampcloth.
•Storethethermometeratroomtemperaturebetween
-4to+149°F/–20to+65°C.
Precautions
•Disposeofusedbatterypromptlyandkeepawayfrom
children.
•Alwayswearaheatresistantglovetotouchthe
stainlesssteelprobeduringorjustaftercooking.
Do not touch with bare hands.
•Keepthebatteries,stainlesssteelprobeandlaser
awayfromchildren.
•Cleantheprobeanddrythoroughlyafteruse.
•Donotcleanthecasewithabrasiveorcorrosive
compound,whichmayscratchtheplasticandcorrode
theelectroniccircuits.
•Donotsubjecttheunittoexcessiveforceshock,
dust,temperatureorhumidity,whichmayresultin
malfunction,shorterelectroniclifespan,damaged
batteryanddistortedparts.
•Donottamperwiththeunit’sinternalcomponents.
Doingsowillinvalidatethewarrantyontheunit
andmaycauseunnecessarybatterydamageand
distortedparts.
•Donotsubjecttheunittoexcessiveexposuretodirect
sunlight.The unit is not waterproof—donotimmerse
itintowaterorexposetoheavyrain.
•Toavoiddeformation,donotplacetheunitinextreme
temperatures.Neverburntheprobedirectlyover
thefire.Donotusetheprobewhenthetemperature
isabove662°F/350°C.Doingsowilldeteriorate
theprobe.
•Donotusethethermometerinamicrowaveoven.
•Alwaysreadtheusersmanualthoroughlybefore
operating.
EMC/RFI
Readingsmaybeaffectediftheunitisoperatedwithinaradio
frequency electromagnetic field strength of approximately
3voltspermeter,buttheperformanceoftheinstrumentwill
notbepermanentlyaffected.
Product specificaties
Merk: | CDN |
Categorie: | Thermometer |
Model: | ProAccurate INTP662 |
Heb je hulp nodig?
Als je hulp nodig hebt met CDN ProAccurate INTP662 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermometer CDN
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
9 Juni 2025
9 Juni 2025
9 Juni 2025
9 Juni 2025
Handleiding Thermometer
- Hartmann
- Klein Tools
- Konig
- Milwaukee
- Nokia
- Welby
- ClimeMET
- BeSafe
- Aponorm
- VDH
- Taylor
- Radiant
- Blue Circle Medical
- AcuRite
- AnD
Nieuwste handleidingen voor Thermometer
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
6 Juni 2025
2 Juni 2025
25 Mei 2025
20 Mei 2025
12 Mei 2025
19 April 2025