Bekijk gratis de handleiding van CDN ProAccurate INTP626X (5 pagina’s), behorend tot de categorie Thermometer. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 4.8 sterren uit 2.5 reviews. Heb je een vraag over CDN ProAccurate INTP626X of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/5

Perfect For
•Non-contactsurfacetemperatures
•Internaltemperaturemeasurementwiththermocouple
probe
Easy To Use
•Rapidresponse
•Data-hold
•One-buttonoperation
•HACCPchecklights&icons
Features
•NSF
®
Certied
•Waterresistant
•1.5mmthintip
•Shatterproof
•Dualfunction
•Maximum,minimumandlockforcontinuousscanning
•Whitelighttargetillumination
•Distance:spot=2.5:1
•Batterystatusindication
•Food-safeABSplasticwithBioCote®
•Auto-offafter15seconds
•Pouch
•Batteryandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeeping
foodsafe.TheversatileINTP626Xisperfectforany
application.Simplypointtheinfraredsensorlenstoward
thetargetandpressSCANtogetaquickreadingof
surfacetemperaturesoripdowntherapid-response
thermocoupleprobetomeasureinternaltemperatures.
IntegratedHACCPchecklightsandiconsinstantlyshow
iftemperaturesarewithinHACCPguidelinesforsafe
foodtemperatures.
Minimum, Maximum and Lock
TheINTP626alsooffersMinimum,Maximum,andLock
modes.Minimummodedisplaysthelowesttemperature
amongmultipletargets.Maximummodedisplaysthe
highesttemperatureamongmultipletargets.WhileLock
modecontinuouslydisplaysthetemperatureforupto
60minutes.Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
Note:Removestickerfromdisplaybeforeuse.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthatappears
onthedisplayisshownin .BOLD CAPS
Battery Installation
Powerofftheunitbeforeinstallingthe
battery.Amalfunctionmayoccurifthe
powerisonwhenthebatteryisinstalled.
Ifamalfunctionoccurs,restartthedevice.
1. Holdingthedeviceontheoutside
edges(donotpressbuttons),pickoff
therubbercaponthebatterycover
usingasmallPhillipsscrewdriver.
2. Removethescrewonthebatterycover
byturningitcounterclockwise.
3. Removethebatterycover,
topedgerst.
4. Installtwo1.5VAAAbatteries
observingpolarityshownin
compartment.
Model: INTP626X
ProAccurate
®
Infrared/
Thermocouple Probe Thermometer
Infrared:-67to+482°F/-55to+250°C
Thermocouple:-67to+626°F/-55to+330°C
probe
HACCP check lights
DUAL
battery cover
rubber cap
(screw location)
white light
infrared lens
infrared reading
probe reading
SCAN button
PROBE button
3
4
1
2

5. Replacethebatterycover,
bottomedgerst.
Important: THE WATER RESISTANT
FEATURE REQUIRES MAINTAINING A
TIGHT FIT FOR THE BATTERY COVER AND
THE RUBBER CAP.
6. Fastenthescrewonthebatterycover
byturningitclockwise.
7. Replacetherubbercapoverthescrew
bypushingitdownsecurely.
Operating Instructions
Mode Selection:MINØMAXØLOCKذC/°FØEMIS
A. Temperature Scale
ToselecttemperaturereadinginFahrenheitorCelsius:
1. PresstheSCANbuttontoturnthethermometeron.
2. PresstheMODEbuttonfourtimes.The or °F °C
symbolashesonthedisplay.
3. PresstheSCANbuttontochangethescale.
B. Infrared Thermometer
InfraredisthedefaultmodeoftheINTP626X.
Note:TheINTP626Xisintendedforfoodserviceuse
—donotuseforsafetyrelatedapplications.
1. Infrared Scanning
a. Distance:Spot = 2.5:1
Forexample,ifthe
surfaceareabeing
measuredis10"in
diameter,thenthe
thermometermustbewithin25"ofthetargetfor
anaccuratereading.
b. Aimtheinfraredlensatthetargetandpressthe
SCANbuttontodisplaythesurfacetemperature.
The white light automatically turns on to
illuminate the target.
c. MeasurementcontinuesaslongastheSCAN
buttonispressed.Thenewestreadingupdates
thedisplay.
d. WhentheSCANbuttonisreleased,HOLD
appearsonthedisplayandthelastreading
remainsvisiblefor15secondsbeforetheunit
automaticallypowersoff.
2. Minimum Mode
a. PresstheSCANbuttontoturnthethermometeron.
b. PresstheMODEbuttononce. ashesonMIN
thedisplay.
c. PressandholdtheSCANbuttontoconrm
theMinimumModeanddisplaythelowest
temperatureamongmultipletargets.
3. Maximum Mode
a. PresstheSCANbuttontoturnthethermometeron.
b. PresstheMODEbuttontwice. ashesonMAX
thedisplay.
c. PressandholdtheSCANbuttontoconrm
theMaximumModeanddisplaythehighest
temperatureamongmultipletargets.
4. Lock Mode
Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
a. PresstheSCANbuttontoturnthethermometeron.
b. PresstheMODEbuttonthreetimes.LOCK
ashesonthedisplay.
c. PresstheSCANbuttontoconrmtheLock
Mode.Thethermometercontinuouslydisplays
thetemperatureforupto60minutesoruntilthe
SCANbuttonispressedagain.
5. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.05(5E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecic
materials,pleasecontactCDN.
a. PresstheSCANbuttontoturnthethermometeron.
b. PresstheMODEbuttonvetimestoenter
EmissivityMode. ashesonthedisplay.95E
c. PresstheSCANbuttontoadjusttheemissivity
valuein0.01(1E)increments.
d. PresstheMODEbuttonagaintoexit
EmissivityMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperature
ofshinyorpolishedmetals.
6. Error Messages
TheINTP626Xincorporatesvisualdiagnostic
messagesasfollows:
a. HI LO or isdisplayedwhenthetemperature
beingmeasuredisoutsidetheinfraredrange
oftheinstrument.
1.)HI indicatesthatthetemperatureishigher
than+482°F/+250°C.
2.)LO indicatesthatthetemperatureislower
than-67°F/–55°C.
b. Allowaminimum30minutesforthethermometer
tostabilizetotheworking/roomtemperature.
1.)ER2 isdisplayedwhenthethermometeris
exposedtorapidchangesintheambient
temperature.
2.)ER3 isdisplayedwhentheambient
temperatureexceeds-32°F/0°COR
+122°F/+50°C.
Distance:Spot(FOV)=2.5:1
Emissivity=0.1~1,Step.01
WaveLength=8µm-14µm
CAUT ION: Never point the un it and/or laser towards
anyone’s eyes. Do not look directly into the laser
beam s — permanent eye damage may re sult. Keep
away from children.
5
6
7

c. Forallothererrormessagesitisnecessary
toresetthethermometer.
1.)Waitforthethermometertopoweroff.
2.)Removethebatteryandwaitforaminimum
ofoneminute.
3.)Reinstallthebattery(seeBattery
Installation).
4.)
PresstheSCANbuttontoturnthe
thermometeron.
5.)Iftheerrormessageremains,pleasecontact
CDNforfurtherassistance.
C. Thermocouple Probe
Important: THE PROBE MAY BE DAMAGED IF
MEASUREMENT TEMPERATURE IS LOWER THAN -67°F/-
55°C OR HIGHER THAN +626°F/+330°C.
1. Flipdowntheprobeuntilfullyextended.
2. Inserttheprobeatleast1"/2.5cmintothefood.
3. PressthePROBEbuttontocontinuouslydisplay
thetemperatureforupto4minutesbeforetheunit
automaticallypowersoff.
Note:PressingthePROBEbuttonmayinterruptthelast
infraredHOLDreading.PressthePROBEbuttonagainto
returntoinfraredscanning.
4. Wearingaheatresistantglove,iptheprobeback
intothecasewhennished.
Important: DO NOT TWIST THE PROBE OR ROTATE IT IN
WRONG DIRECTION. EXCEPTIONAL STRESS ON PROBE MAY
CAUSE IT TO BREAK.
CAUTION:ProbemaybeHOTafteruse.Alwaysweara
heatresistantglovetotouchthestainlesssteelprobeor
sensorcableduringorjustaftercooking.Do not touch
with bare hands.
D. HACCP Check
IntegratedHACCPchecklights
andiconsinstantlyshowif
temperaturesarewithinHACCP
guidelinesforsafefoodtemperatures.
Note:TheGREENandREDlightswillalwaysbelitbefore
poweroff.
1. A lightabovetheGREEN
SNOWFLAKE icon( )indicates
asafecoolorfrozencondition
below40°F/4°C.
2. A lightabovetheGREEN HOT
CUPicon( )indicatesasafeholdingtemperature
above140°F/60°C.
3. A lightabovethe icon( )indicatesRED DON’T EAT
thatthetemperatureiswithintheHACCP Danger
Zoneof40to140°F/4to60°C.
E. Battery Status
Thethermometerincorporatesvisualbatterystatus
indication:
1. measurementsarepossibleBattery OK:
2. replacebatterywithtwo1.5VAAABattery Low:
Alkalinecells;measurementsarepossible
3. replacebattery;Battery Exhausted:
measurementsarenotpossible
Care of Your Product
•Thesensorlensisthemostdelicatepartofthe
thermometerandshouldbekeptcleanatalltimes.
Takecarewhencleaningthelens.Useonlyasoftcloth
orcottonswabwithwaterorrubbingalcohol.Allowthe
lenstodryfullybeforeusingthethermometer.
•Donotsubmergeanypartofthethermometerinwater.
Wipecleanwithadampcloth.
•Storethethermometeratroomtemperaturebetween
-4to+149°F/–20to+65°C.
Precautions
•Disposeofusedbatterypromptlyandkeepawayfrom
children.
•Alwayswearaheatresistantglovetotouchthe
stainlesssteelprobeduringorjustaftercooking.
Do not touch with bare hands.
•Keepthebatteries,stainlesssteelprobeandsensor
cableawayfromchildren.
•Cleantheprobeanddrythoroughlyafteruse.
•Donotcleanthecasewithabrasiveorcorrosive
compound,whichmayscratchtheplasticandcorrode
theelectroniccircuits.
•Donotsubjecttheunittoexcessiveforceshock,
dust,temperatureorhumidity,whichmayresultin
malfunction,shorterelectroniclifespan,damaged
batteryanddistortedparts.
•Donottamperwiththeunit’sinternalcomponents.
Doingsowillinvalidatethewarrantyontheunitand
maycauseunnecessarybatterydamageanddistorted
parts.
•Donotsubjecttheunittoexcessiveexposuretodirect
sunlight.The unit is not waterproof—donotimmerse
itintowaterorexposetoheavyrain.
•Toavoiddeformation,donotplacetheunitinextreme
temperatures.Neverburntheprobedirectlyoverthe
re.Donotusetheprobewhenthetemperatureis
above626°F/330°C.Doingsowilldeterioratethe
probe.
•Donotusethethermometerinamicrowaveoven.
•Alwaysreadtheusersmanualthoroughlybefore
operating.
EMC/RFI
Readingsmaybeaffectediftheunitisoperatedwithinaradio
frequency electromagnetic eld strength of approximately
3voltspermeter,buttheperformanceoftheinstrumentwill
notbepermanentlyaffected.
Product specificaties
Merk: | CDN |
Categorie: | Thermometer |
Model: | ProAccurate INTP626X |
Heb je hulp nodig?
Als je hulp nodig hebt met CDN ProAccurate INTP626X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermometer CDN
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
9 Juni 2025
9 Juni 2025
9 Juni 2025
9 Juni 2025
Handleiding Thermometer
- Radiant
- Oregon Scientific
- Taylor
- Bioland
- Mobi
- Laserliner
- Motorola
- Turbotronic
- Geratherm
- Okoia
- Bartscher
- ClimeMET
- Aspen
- Techno Line
- AEG
Nieuwste handleidingen voor Thermometer
10 Juni 2025
10 Juni 2025
10 Juni 2025
10 Juni 2025
6 Juni 2025
2 Juni 2025
25 Mei 2025
20 Mei 2025
12 Mei 2025
19 April 2025