CDN IN1022 Handleiding

CDN Thermometer IN1022

Bekijk gratis de handleiding van CDN IN1022 (5 pagina’s), behorend tot de categorie Thermometer. Deze gids werd als nuttig beoordeeld door 11 mensen en kreeg gemiddeld 4.3 sterren uit 6 reviews. Heb je een vraag over CDN IN1022 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
Perfect For
•Non-contactsurfacetemperatures
Easy To Use
•1-secondresponse
•8-beamlasertargetillumination
•Backlit
•Data-hold
•One-buttonoperation
Features
•Memory
•Maximum,minimum,difference,averagewithlockfor
continuousscanning
•Highandlowalerts
•Distance:spot=12:1
•Batterystatusindication
•ABSplastic
•Auto-off
•Batteriesandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeepingfood
safe.TheversatileIN1022isperfectforanyapplication.
Simplypointtheinfraredsensorlenstowardthetarget
andpressthetriggertogetaquickreadingofsurface
temperatures.
Maximum, Minimum, Difference
and Average Modes
TheIN1022alsooffersMaximum,Minimum,Difference
andAveragemodes.Maximummodedisplaysthehighest
temperatureamongmultipletargets.Minimummode
displaysthelowesttemperatureamongmultipletargets.
Differencemodedisplaysthedifferencebetweenthe
maximumandminimumtemperaturemeasurements
ofmultipletargets.WhileAveragemodedisplaysthe
averagetemperaturemeasurementsofmultipletargets.
Lock Mode
Lockmodecontinuouslymeasuresthetemperature
forupto60minutes.Thisisparticularlyusefulfor
continuoustemperaturemonitoring.
High and Low Alerts
TheIN1022providesaprogrammablehighandlowalert
formeasurementsthatareoutofthedesiredrange.
Note:Removestickerfromdisplaybeforeuse.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthatappears
onthedisplayisshowninBOLD CAPS.
Battery Installation
ReplacebatterywhenLCDbecomesdimoralarm
leveldeclines.Powerofftheunitbeforeinstallingthe
batteries.Amalfunctionmayoccurifthepowerison
whenthebatteryisinstalled.Ifamalfunctionoccurs,
restartthedevice.
1. Removebatterycoverbyslidingitinthedirectionof
thearrow.
2. Installtwo1.5VAAAbatteriesobservingpolarity
shownincompartment.
3. Replacethebatterycoveruntilitclicksshut.
Model: IN1022
Infrared Gun
-76to+1022°F/-60to+550°C
Operating Instructions
Mode Selection: E
Ø
Eâ á
Ø
MAX
Ø
MIN
Ø
DIF
Ø
AVG
Ø
HAL
Ø
LAL
A. Temperature Scale
ToselecttemperaturereadinginFahrenheit
orCelsius:
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. Pressthe°C/°Fbuttontochangethescale.
B. Backlit Display
Toturnthebacklitdisplayonandoff:
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. Pressandholdthetriggerandthenalsopress
theLOCKbuttontoturnthebacklitdisplayonand
off.TheBACKLIGHT icon( )appearsinthetop
portionofthedisplaywhenon.
C. Laser Light
Toturnthelaserlightonandoff:
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. Pressandholdthetriggerandthenalsopressthe
C°/F°buttontoturnthelaserlightonandoff.The
LASER icon( )appearsinthetopportionofthe
displaywhenon.
E. Lock Mode
Thisisparticularlyusefulforcontinuoustemperature
monitoringforupto60minutesandcanbeusedwith
Minimum,Maximum,DifferenceandAveragemodes.
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheLOCKbutton. appearsinthetopLOCK
portionofthedisplaywhenon.
3. Thethermometercontinuouslydisplaysthe
temperatureforupto60minutesorrestartsthe
timeifthetriggerispressedagain.
F. Infrared Thermometer
Note:TheIN1022isintendedforfoodserviceuse—donotusefor
safetyrelatedapplications.
1. Infrared Scanning
1. Distance:Spot = 12:1
Forexample,ifthesurface
areabeingmeasuredis
10"indiameter,thenthethermometermustbe
within120"ofthetargetforanaccuratereading.
2. Aimtheinfraredlensatthetargetandpress
thetriggertodisplaythesurfacetemperature.
Ifon,thelaserlightautomaticallyilluminates
thetarget.
3. The8-beamlaserlightformsacirclethatdenes
theareaofmeasure.Makesurethecircleis
smallerthantheareabeingmeasured.Ifthe
laserlightcircleislargerthantheareabeing
measured,thereadingwillincludeambient
temperaturesandmakethereadinginaccurate.
4. Measurementcontinuesaslongasthetriggeris
pressed.Thenewestreadingupdatesthedisplay.
5. Whenthetriggerisreleased, appearsonHOLD
thedisplayandthelastreadingremainsvisible
for60secondsbeforetheunitautomatically
powersoff.
2. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.1(10E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecic
materials,pleasecontactCDN.
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonuntil appearsintheE
lowerleftcornerofthedisplay.Thecurrent
emissivitysettingappearsinthelowerright
cornerofthedisplay
3. PresstheMODEbuttonagaintoadjustthe
emissivityvaluein0.01(1E)incrementsinthe
EmissivityEditMode.âEáappearsinthelower
leftcornerofthedisplay.
4. Pressthe°C/°Fbuttontodecreasethe
emissivityvalue.PresstheLOCKbuttonto
increasetheemissivityvalue.Pressandholdfor
fastadvance.
5. PresstheMODEbuttonagaintoexitEmissivity
EditModeandenterMAXMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
3. Maximum Mode
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntilMAX
appearsinthelowerleftportionofthedisplay.
3. Aimtheinfraredlensatthetargetandpressthe
triggertodisplaythesurfacetemperature.
4. Measurementcontinuesaslongasthetrigger
ispressedorfor60minutesinLockMode.
TheMAXreadingdisplaysthehighest
temperatureamongmultipletargets.
4. Minimum Mode
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntilMIN
Distance:Spot(FOV)=12:1
Emissivity=0.1~1,Step.01
WaveLength=8µm-14µm
CAUTION: Never point the unit and/or laser towards
anyone’s eyes. Do not look directly into the laser
beams permanent eye damage may result. Keep
away from children.
appearsinthelowerleftportionofthedisplay.
3. Aimtheinfraredlensatthetargetandpressthe
triggertodisplaythesurfacetemperature.
4. Measurementcontinuesaslongasthetrigger
ispressedorfor60minutesinLockMode.
TheMINreadingdisplaysthelowesttemperature
amongmultipletargets.
5. Difference Mode
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntilDIF
appearsinthelowerleftportionofthedisplay.
3. Aimtheinfraredlensatthetargetandpressthe
triggertodisplaythesurfacetemperature.
4. Measurementcontinuesaslongasthetrigger
ispressedorfor60minutesinLockMode.
TheDIFreadingdisplaysthedifferencebetween
themaximumandminimumtemperaturesof
multipletargets.
6. Average Mode
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntilAVG
appearsinthelowerleftportionofthedisplay.
3. Aimtheinfraredlensatthetargetandpressthe
triggertodisplaythesurfacetemperature.
4. Measurementcontinuesaslongasthetrigger
ispressedorfor60minutesinLockMode.
TheAVGreadingdisplaystheaverage
temperatureofmultipletargets.
7. Error Messages
TheIN1022incorporatesvisualdiagnostic
messagesasfollows:
1. or isdisplayedwhenthetemperatureHI LO
beingmeasuredisoutsidetheinfraredrangeof
theinstrument.
a. HIindicatesthatthetemperatureishigher
than+1022°F/+550°C.
b. LOindicatesthatthetemperatureislower
than-76°F/–60°C.
2. Allowaminimum30minutesforthe
thermometertostabilizetotheworking/room
temperature.
a. ER2isdisplayedwhenthethermometeris
exposedtorapidchangesintheambient
temperature.
b. ER3isdisplayedwhentheambient
temperatureexceeds32°F/0°COR
12F/50°C.
3. Forallothererrormessagesitisnecessaryto
resetthethermometer.
a. Waitforthethermometertopoweroff.
b. Removethebatteryandwaitforaminimum
ofoneminute.
c. Reinstallthebattery(seeBattery Installation).
d. PresstheMODEbuttonortriggertoturnthe
thermometeron.
e. Iftheerrormessageremains,pleasecontact
CDNforfurtherassistance.
G. Temperature Alerts
1. High Alert
Analertwillsoundwhenthemeasuredtemperature
exceedsthealerttemperaturesetting.
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntil HAL
appearsinthelowerleftportionofthedisplay.
3. Pressthe°C/°FbuttontodecreasetheHigh
Alerttemperature.PresstheLOCKbuttonto
increasetheHighAlerttemperature.Pressand
holdforfastadvance.
4. PressthetriggertoconrmtheHighAlert
temperaturesetting.
2. Low Alert
Analertwillsoundwhenthemeasuredtemperature
exceedsthealerttemperaturesetting.
1. PresstheMODEbuttonortriggertoturnthe
thermometeron.
2. PresstheMODEbuttonrepeatedlyuntil LAL
appearsinthelowerleftportionofthedisplay.
3. Pressthe°C/°FbuttontodecreasetheLow
Alerttemperature.PresstheLOCKbuttonto
increasetheLowAlerttemperature.Pressand
holdforfastadvance.
4. PressthetriggertoconrmtheLowAlert
temperaturesetting.
H. Battery Status
Thethermometerincorporatesvisualbatterystatus
indication:
1. measurementsarepossibleBattery OK:
2. replacebatterywithtwo1.5VBattery Low:
AAAAlkalinecells;measurementsarepossible
3. replacebattery;Battery Exhausted:
measurementsarenotpossible
EMC/RFI
Readingsmaybeaffectediftheunitisoperatedwithinaradio
frequency electromagnetic eld strength of approximately
3voltspermeter,buttheperformanceoftheinstrumentwill
notbepermanentlyaffected.


Product specificaties

Merk: CDN
Categorie: Thermometer
Model: IN1022

Heb je hulp nodig?

Als je hulp nodig hebt met CDN IN1022 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden