Wachendorff TI484801 Handleiding


Bekijk gratis de handleiding van Wachendorff TI484801 (2 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 17 mensen en kreeg gemiddeld 4.1 sterren uit 8 reviews. Heb je een vraag over Wachendorff TI484801 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Operating
temperature
Sealing
Material
DigitalInputs
Outputs
OUT24V
Back-UP
PowerSupply
TECHNICALDATATECHNICALDATA
Operatingtemperature0-40°C,humidity
35..95uR%
IP65(withgasket)onfrontpanel,
IP20boxandterminalblocks
PCABSUL94V0self-extinguishing
3PNP/NPNconfigurableasanaloguefor
potentiometers.(max28VdcinPNPmode)
2relays8Aresistivecharge
30mA(24Vac),40mA(24Vdc),60mA(110...230Vac)
Rechargeablebattery,approx.60daysautonomy
24...230Vac/Vdc+/-15%50/60Hz/2W
.
INTRODUCTION
ThanksforchoosingaWachendorffdevice.
ThetimerTI484801canbesetin5differentmodes;Timer-ON,Timer-
OFF,Pause-Work,Oscillator,PWM(time-proportionedoutput),all
optionswithindependentsettingsofON-OFFtime.
3universaldigitalinputsareavailables(NPN/PNP/Potentialfree
contact)forexternalcommandslikeStart,StopandReset;oneinputis
alsoanalogueinordertoallowthemodificationofworkingtimesbyan
externalpotentiometer.
5differenttimebases(hundredths,tenths,seconds,minutes,hours).
Countingcanbeincrementalordecremental.
MEMORYCARD(optional)MEMORYCARD(optional)
Parametersandsetpointvaluescanbecopiedfromonedevicetoanotherusing
theMemorycard
Therearetwomethods:
insertthememorycard.
Onactivationdisplay1showsanddisplay2shows
Thedeviceloadsthenewdataandstartsagain
Thememorycardisequippedwithaninternalbatterywithalifeofabout1000uses.
Insertthememorycardandpresstheprogrammingbutton.
Whenwritingtheparameters,theLEDturnsredandoncompletingtheprocedure
itchangestogreen.Itispossibletorepeattheprocedure.
Tothememorycardvalues,followtheproceduredescribedinthefirst
method,settingdisplay2tosoasnottoloadtheparametersoncontroller.
Enterconfigurationand.
Exitconfiguration.Changesaresavedautomatically.
Thisprocedurerestoresthefactorysettingsoftheinstrument.
Withthedeviceconnectedtothepowersupply
whenthecontrollerisoff
Withthecontrollerdisconnectedfromthepowersupply:
changeatleastoneparameter
update
LOADINGDEFAULTVALUES
.
(OnlyifthevaluesstoredonMmeoryCardarecorrect).
Bypressingthekeydisplay2shows
Confirmusingthekey.
.
Attention:Pls.performanupdateofthememorycardfirst.
>
>
UPDATINGMEMORYCARD.
LISTOFPARAMETERSLISTOFPARAMETERS
Potentiometer:
1-
2-
3-
4-
TomodifySet1orSet2byexternalpotentiometerfollowthestepsbelow:
usepotentiometers0to5/10kohm
connectcursortopinI3;awrongconnectionmaydamagethepotentiometerand
leadtolockofthedevice.
accuracyoninputismax1000points,thereforesettheparameters"Upperlimit"
and"Lowerlimit"withamaxdifferenceof1000units.
(Ex.:LoS1to50,0anduPS1to150,0tomodifytimevaluerelatedtoSet1between
50and150secondswithstepsofonetenth).Greaterdifferenceswouldmake
unstablethelesssignificantdigit.
Tocalibratethescaleofpotentiometerentertheconfigurationmodeandselect:
Hin.3asPot
Fin.3asSet1orSet2
P.tArasEnable
Exitconfigurationmodeandplacepotentiometeratminimumlevelandpresskey,
thenplacepotentiometeratmaxlevelandpresspremerekey:thedevice
automaticallyexitthecalibrationprocedure.
N.B.:Aswitch-offofthedevicewouldinterruptthecalibration.
P-01TimerFunction
FUNCTIONCONFIGURATION
P-02Power-offMemory
Disable
OnlyTimer
Timer/State
BACKUPMEMORYCONFIGURATION
P-03HardwareInput1
INPUTCONFIGURATION
Timerfunctions
Activatesoutputatcountend
Deactivatesoutputatcountend
T1andT2startinsequency
Percentageoutputactivationonfixedtimebase
T1andT2startinsequencyrepeatedly
Power-offmemory
Disabled
Onlytimervalueinmemory
TimervalueandSTART/STOPstatusinmemory
NPN
PNP
TTL
NPN
PNP
TTL
P-04HardwareInput2
Input1configuration
NPN
PNP
TTL
NPN
PNP
TTL
Input2configuration
Default
Default
Default
Default
PRESS
VisualizesSETPOINT1/2
DISPLAY
or
ModifiesselecterSET
1
2
SETPOINTMODIFICATIONSETPOINTMODIFICATION
PRESS
Ondisplay1appears
with1stdigitblinking,while
display2shows
DISPLAYDO
or
Modifyblinkingdigitand
passtothenextonepressing
EnterPassword
toconfirm
Displayshowsfirstparameterof
configurationtable
1
2
3
Scrollparameters
4
or
Increaseordecreasevisualizedvalue
pressingandanarrowkey
Enterthenewdata
thatwillbe
savedwhenreleasingkeys
5
+or
Endconfiguration,controllerexits
fromconfiguration
6
CONFIGURATIONPARAMETERMODIFICATIONCONFIGURATIONPARAMETERMODIFICATION
SETfor
3seconds
+
PRESS
Ondisplay1appears
with1stdigitblinking,while
display2shows
DISPLAYDO
or
Modifyblinkingdigitand
passtothenextonepressing
EnterPassword
toconfirm
Deviceloads
defaultvalues
Switchthedeviceoff
andrestartit
1
2
3
LOADINGDEFAULTVALUESLOADINGDEFAULTVALUES
SETfor
3seconds
SETPOINTCONFIGURATION
OUTPUTCONFIGURATION
DISPLAYCONFIGURATION
P-05HardwareInput3
P-06ActiveStateInput1
P-07ActiveStateInput2
P-08ActiveStateInput3
PNP
TTL
Potent.
HighLevel
LowLevel
Risingedge
HighLevel
LowLevel
Risingedge
HighLevel
LowLevel
Risingedge
Input3configuration
Input1activation
Input2activation
Input3activation
PNP
TTL
Potentiometer
Highlevel
Lowlevel
Transitoryinrising
Highlevel
Lowlevel
Transitoryinrising
Highlevel
Lowlevel
Transitoryinrising
P-09FunctionInput1
P-12FunctionKeyUP
P-10FunctionInput2
P-11FunctionInput3
P-16FormatSet1
P-18DisplaySet1
P-17FormatSet2
P-19DisplaySet2
P-13OutputQ1Setup
P-14OutputQ2Setup
P-15TypeofTimer
Disable
Start/Stop
Start/Stop-Reset
Reset-Start/Stop
Reset/Start/Stop
Second.Cent
Second.Decimal
Second
Minute.Second
Hour.Minute
Hour
Disable
Start/Stop
Start/Stop-Reset
Reset-Start/Stop
Reset/Start/Stop
Reset
Wait
Hold
Disable
OutTimer1n.o.
OutTimer1n.c.
OutTimer2n.o.
OutTimer2n.c.
Start
Stop
Disable
OutTimer1n.o.
OutTimer1n.c.
OutTimer2n.o.
OutTimer2n.c.
Start
Stop
Incremental
Decremental
Disable
Visualized
Modifiable
Disable
Visualized
Modifiable
Disable
Enable
P-24Potent.tarature
P-20LowerlimitSet1
P-21UpperlimitSet1
P-22LowerlimitSet2
P-23UpperlimitSet2
Disable
Reset
Disable
Wait
Hold
Potent.ToSET1
Potent.ToSET2
Input1function
Functionof
Input2function
Input3function
Countformat
Set1visualization
Countformat
Set2visualization
OutputQ1selection
OutputQ2selection
Countmode
Disabled
Start/Stop
Start/Stop-Reset
Reset-Start/Stop
Reset/Start/Stop
Seconds,Cents
Seconds,Tenths
Seconds
Minutes,Seconds
Hour,Minutes
Hour
Disabled
locksdisplaybutcountcontinuels
Start/Stop
Start/Stop-Reset
Reset-Start/Stop
Reset/Start/Stop
Reset
Wait(countlock)
Hold()
Disabled
Timeroutput1n.c.
Timeroutput2n.o.
Timeroutput2n.c.
Timeroutput1n.o.
Start
Stop
Disabled
Timeroutput1n.o.
Timeroutput1n.c.
Timeroutput2n.o.
Timeroutput2n.c.
Start
Stop
Incremental
Decremental
Disabled
Visualized
Visualizedandmodifiable
Disabled
Visualized
Visualizedandmodifiable
Disabled
Enabled
Potentiometercalibrationprocedure
Set1lowerlimit
Set1upperlimit
Set2lowerlimit
Set2upperlimit
Reset
Disabled
ModifySET1bypotentiometer
Disabled
Wait(countlock)
Hold(locksdisplaybutcountcontinues)
ModifySET2bypotentiometer
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
Default
0.0
0.0
99.9
99.9
Default
SIZEANDINSTALLATIONSIZEANDINSTALLATION
TimerOn
TimerOff
Pause/Work
Oscillator
PWM
NPN
PNP
POTENTIOMETER0to5/10Kohm
Accuracy1.000points
PNP
NPN
WIRINGDIAGRAMWIRINGDIAGRAM
-
+
OUTPUT
5
4
3
2
1
I3
10
9
8
7
6
SUPPLY
24...230V
AC/DC
8A230V
Resistiv
1/2HP
CAUTION
RiskofElectricShock
Disconnectpower
supplybefore
servicing
I2
I1
OUT24V
Q2
8A230V
Resistiv
1/2HP
Q1
Proximity
SensorPNP
3wires
Proximity
SensorPNP
2wires
I1
I2
I3
I1
I2
I3
5
4
3
2
1
I3
10
9
8
7
6
SUPPLY
24...230V
AC/DC
8A230V
Resistiv
1/2HP
CAUTION
RiskofElectricShock
Disconnectpower
supplybefore
servicing
I2
I1
OUT24V
Q2
8A230V
Resistiv
1/2HP
Q1
5
4
3
2
1
I3
10
9
8
7
6
SUPPLY
24...230V
AC/DC
8A230V
Resistiv
1/2HP
CAUTION
RiskofElectricShock
Disconnectpower
supplybefore
servicing
I2
I1
OUT24V
Q2
8A230V
Resistiv
1/2HP
Q1
5
4
3
2
1
I3
10
9
8
7
6
SUPPLY
24...230V
AC/DC
8A230V
Resistiv
1/2HP
CAUTION
RiskofElectricShock
Disconnectpower
supplybefore
servicing
I2
I1
OUT24V
Q2
8A230V
Resistiv
1/2HP
Q1
ReporttheactivationofQ1
MEANING
ReporttheactivationofQ2
LED
ReportserialtransmissionbytheTI484801
A3
MANTUNREM
C1C1
C2C2
A1
A2
A3
MANTUNREM
C1C1
C2C2
A1
A2
A3
MANTUNREM
C1C1
C2C2
A1
A2
Readcarefullythesafetyguidelinesandprogramminginstructions
containedinthismanualbeforeusing/connectingthedevice.
Disconnectpowersupplybeforeproceedingtohardwaresettingsor
electricalwirings.
Onlyqualifiedpersonnelshouldbeallowedtousethedeviceand/or
serviceitandinaccordancetotechnicaldataandenvironmental
conditionslistedinthismanual.
Donotdisposeelectrictoolstogetherwithhouseholdwastematerialsin
observanceofEuropeanDirective2002/96/CE
48mm
48mm
Frontpanel
cutout
46x46mm
2tomm
suggestedthickness
6
106mm10
A3
MANTUNREM
C1C1
C2C2
A1
A2
16
MemoryCard
Insertionof
memorycard(optional)
1
5
2
3
4
5
4
3
2
1
I3
10
9
8
7
6
Versorg.
24...230V
AC/DC
8A230V
Resistiv
1/2HP
ACHTUNG
Gefahreineselektr.
Schlags.SchaltenSie
dieVersorgungvor
dem
Serviceab.
I2
I1
OUT
2
4V
50mA
Q2
8A230V
Resistiv
1/2HP
Q1
MEMORYC.241MEMORYC.241
CN1
16
MANUAL
TIMERTI484801
MANUAL
TIMER
TI484801
WachendorffProzesstechnikGmbH&Co.KG
www.wp-direkt.de
Version2.0

Beoordeel deze handleiding

4.1/5 (8 Beoordelingen)

Product specificaties

Merk: Wachendorff
Categorie: Meetapparatuur
Model: TI484801

Heb je hulp nodig?

Als je hulp nodig hebt met Wachendorff TI484801 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden