Vemer Sensor-360 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Vemer Sensor-360 (1 pagina's) in de categorie Bewegingsdetector. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
User manual
Movement detector
Read all instructions carefully
The
Sensor-360
proximity switch is electronic switching device containing
micro-disconnection (μ) according to EN 60669-2-1. The output circuit is activated when a
heat source moves in front of the device and is deactivated when no movement is intercepted,
after a settable period of elapsed time.
SAFETY WARNINGS
During installation and operation of the instrument, comply with the following
instructions:
1) The instrument must be installed by a skilled person, in strict compliance with the
connection diagrams
2) Do not power on or connect the instrument if any part of it is damaged
3) In the building where the instrument is to be installed, there must be a switch and a
device for protection from overloads
4) Before touching the connector terminals make sure that the wires to be connected or
already connected to the instrument are not live.
Code Model Description
VP403000 Sensor-360 Movement detector 360°
TECHNICAL CHARACTERISTICS
Power supply: 230V AC 50Hz
Breaking capacity: 10A 250V AC (resistive load)
Maximum recommended loads:
− Incandescent light bulbs: 1000W
− Non-compensated uorescent: 500W
− Compensated uorescent: 250W
− Halogen (230V AC): 1000W
− Low consumption bulbs: 200W
Consumption: < 2W
Range of brightness: 3-300- lux
Time range: from 3 seconds to 10 minutes (approximate)
Detection angle: 360°
Maximum detection height: 5 m
Operating temperature: -20 °C ÷ +40 °C
Protection degree: IP20
Insulation: class II
INSTALLATION
The device must be installed far from inductive loads (motors, transformers, telephone
antennas, transformer plants, industrial machinery, etc.) as especially strong magnetic
elds may alter operation. The device must also be protected from rain and sunlight.
It must not be placed near lights, near devices that are subject to temperature changes
(heating, air conditioning). It must be located far from highly reective surfaces.
The detection area directly depends on the installation height. In particular, an
installation at 2.5 meters height, permits to detection a eld of 3.5 meters ray.
The sensibility is instead inuenced by the environment temperature (the higher
the temperature, the worse the sensitivity because the unit operates by detecting the
movement of a heat source) and by the direction of the movement.
GREATER SENSITIVITY
direction of
movement
direction of
movement
LESS SENSITIVITY
OPERATION
To install the instrument, remove the cover and set the selectors.
To set the detection eld:
− rotate the “lux” selector to the “ ” position and the “time” selector to the ” position;
− check coverage by moving within the detection eld limits.
The device permits to limit the eld of the detection area. To exclude one or more sectors,
applied a piece of insulating tape on the relative part of the sensor.
The Sensor-360 proximity switch can be adjusted to that it only operates when the
lighting conditions are below the selected level. By turning the “lux” selector to the
position, it will react under any luminosity conditions. By turning it to the ” position, it
will only react under low luminosity conditions.
The “time” selector permits to set the switch-on delay.
It’s possible to choice from 3 seconds ” to 10 minutes “ ”.
REFERENCE STANDARDS
Conformity to the EU directives:
2014/35/UE (LDV), 2014/30/UE (EMCD)
is declared with reference to harmonized standard: EN 60669-2-1
Mod. Sensor-360
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.
Dimensions
46138.5
26
Connection diagrams
L N
NL
µ
Operation
SELECTORS
CENTRING INDEX
SENSOR


Product specificaties

Merk: Vemer
Categorie: Bewegingsdetector
Model: Sensor-360

Heb je hulp nodig?

Als je hulp nodig hebt met Vemer Sensor-360 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Bewegingsdetector Vemer

Handleiding Bewegingsdetector

Nieuwste handleidingen voor Bewegingsdetector