Vemer Sensor 2LED Handleiding

Vemer Bewegingsdetector Sensor 2LED

Lees hieronder de 📖 handleiding in het Nederlandse voor Vemer Sensor 2LED (1 pagina's) in de categorie Bewegingsdetector. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
User manual
Movement detectors with LED headlight
Read all instructions carefully
The
Sensor LED
and
Sensor 2LED
proximity switches and are electronic switching devices
containing micro-disconnection (μ) according to EN 60669-2-1. They have an LED headlight
(single for Sensor LED, double for Sensor 2LED) that is activated when a heat source moves in
front of the device and is deactivated when no movement is intercepted, after a settable period
of elapsed time. They also have a relay for the connection of an external device (an auxiliary
headlight, an audible alarm, ...) which is activated simultaneously with the headlight.
SAFETY WARNINGS
During installation and operation of the device, comply with the following instructions:
1) The device must be installed by a skilled person, in strict compliance with the
connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) In the building where the device is to be installed, there must be a switch and a
device for protection from overloads
4) Before touching the connector terminals make sure that the wires to be connected
are not live.
Code Model Description
VE767200 Sensor LED Movement detector 200° with LED headlight 13W
VE767300 Sensor 2LED Movement detector 200° with 2 LED headlights 2x13W
TECHNICAL CHARACTERISTICS
Power supply: 230V AC 50Hz
Type of LED headlight:
- Sensor LED: 1x13W, 1000 lm
- Sensor 2LED: 2x13W, 2000 lm
- Colour temperature: 4000K
Relay with breaking capacity of 10A / 250V AC (on resistive load)
Maximum cables section: 2 x 1.5 mm2
Range of brightness: 5-1000 lux
Intervention time: from 3 seconds to 30 minutes (approximate)
Angle of detection: 200°
Range of detection: − frontal 12m at 20°C
− lateral 8m at 20°C
Operating temperature: -20 °C ÷ +40 °C
Protection degree: IP55
Insulation: class II
INSTALLATION
The device must be installed far from inductive loads (motors, transformers, telephone
antennas, transformer plants, industrial machinery, etc.) as especially strong magnetic
elds may alter operation. The device must also be protected from sunlight. It must not
be placed near lights, near devices that are subject to temperature changes (heating, air
conditioning). It must be located far from highly reective surfaces.
Remove the cover by loosening the screw at the bottom. Fasten the base cover at the point
on the wall where you want to install it, at a height of 2-3 metres.
The direction of movement of the heat source must be transversal to lens of the device,
because detection occurs by means of intersection of bands. Therefore, if source moves
parallel to the bands, detection will occur at a lesser distance. The ambient temperature
also affects the sensitivity of the device. The higher the temperature, the poorer sensitivity
will be.
The head can rotate horizontally of about 180° and vertically of about 45°. To adjust the
eld of detection:
turn the intervention time selector to the minimum and the brightness selector to ( );
check coverage by moving inside the eld of detection.
The device is also equipped with limiters of the detection area which, if applied to the lens,
make it possible to exclude one or more sectors of the eld of detection.
To adjust the brightness, turn the selector towards ( ); when the ambient brightness
is as desired for operation, start turning the selector the other way, until illumination
occurs.
To adjust the intervention time, turn the selector ( ) to the desired position. You can
choose from a minimum of 3 seconds to a maximum of 30 minutes. This time is reset
each time there is an interception by the detector.
GREATER SENSITIVITY
direction of
movement
direction of
movement
LESS SENSITIVITY
OPERATION
At start and after each restoring of the power supply after a blackout, the sensor activates
the LED headlight and the load connected for 30 seconds, regardless of the brightness
level and the actual presence of movement in the eld of detection.
During normal operation, when the level of brightness drops below the set level, the
device sets up for detection, and signals this condition via ashing of the internal LED.
REFERENCE STANDARDS
Conformity to the EU directives:
2014/35/EU (LDV)
2014/30/EU (EMCD)
is declared with reference to harmonized standard:
EN 60598-1/EN 60598-2-1
Incandescent
Non-compensated fluorescent
Compensated fluorescent
Halogen (230V)
LED
Low consumption lamp (CFL)
1000 W
500 VA
150 VA
1000 W
125 VA
250 VA
Dimensions
Sensor LED
Sensor 2LED
A1
100
135
A2
150
185
L
175
205
P1
155
170
P2
175
190
A1
A2
L P1
P2
Wall-mounting
Connection diagrams
L' N L
L
N
µ
230 V AC
LAMPADA
L' N L
Mod. Sensor LED
Sensor 2LED
ISCOM058-2106
ADDITIONAL
LAMP
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efcient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.