Desktop UPS Line Interactive UPS
UPS1P600E
Inspection
The following items are inside the box:
UPS unit User manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If damage is discovered,
re-pack the unit and return it to the place of purchase.
Connecting to Utility Power
Connect the AC power cord to the UPS and to your power source.
The UPS will start to charge the battery. For best results, charge
the battery for 6 hours prior to initial use.
Connecting Modem/Phone Line
This UPS protects a single line (1 in/1 out) phone, modem, or fax
machine from surges when connected through the UPS. Plug the
incoming RJ-11 cable into the “IN” socket and the outgoing RJ-11
cable into the “OUT” socket.
A Battery backed-up outlets:
B AC input
C USB com. port (option)
D Modem/Phone line surge protection (option)
Plugging in Equipment
Plug your equipment into outlets on the rear panel of the UPS.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup outlets of UPS. The equipment may draw
significantly more power than UPS can provide, overloading the
UPS.
Connecting to USB Communications Port and
Installing ViewPower Software
Connect one end of the USB cable to PC and the other to the USB
port at the rear of the UPS.
Download the latest version of ViewPower software and manuals
from http://www.v7world.com/us/downloads to your hard drive.
Follow on-screen instructions to complete the software installation.
Operation Display
UPS
Mode
LCD
Description
UPS
Power on
When UPS is powered
on, it will enter this mode
for 4 seconds.
AC Mode
When AVR is
functioning, icon will
flash every second.
LCD information will be
displayed in the following
order when LCD is
touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in AC
mode
icon will flash.
If overload occurs, alarm
will beep every 0.5
second.
Battery
Mode
When battery level is
low, icon will flash.
Alarm will beep every 10
seconds and LCD
information will be
displayed in the following
order when LCD is
touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in battery
mode
icon will flash.
When overload occurs,
alarm will beep every 0.5
second.
NOTE: If backlight shuts off, you may activate it by touching the
screen.
Fault Code Table:
Fault condition
LCD
Solutions
Output short
circuited
Disconnect short-circuited loads
and restart the UPS again.
Overload fault
Disconnect all output loads and
restart the UPS again.
Overcharge
Call for service immediately.
Bad or severely
discharged battery
Please replace the battery.
High output voltage
fault
Call for service immediately.
Over-temperature
1. Turn off the unit and wait for
cooling.
2. Or remove excessive loads
and wait for cooling.
If fault alarm occurs, record the fault and contact
techsupportV7@ingrammicro.com immediately.
INSTALLATION & OPERATION
REAR PANEL
LCD DISPLAY
Desktop UPS Line Interactive UPS
UPS1P600E
This UPS utilizes voltage that may be hazardous. Do not
attempt to disassemble the unit. The unit contains no user
replaceable parts. Only factory-authorized service personnel
may perform repairs.
Install the UPS close to an easily accessible power source.
Note: During the installation of this equipment the sum current
leakage of the UPS and connected loads does not exceed
3.5mA.
Connection to any other type of receptacle other than a
two-pole, three-wire grounded receptacle may result in shock
hazard and violate local electrical codes.
In the event of an emergency to properly disable the UPS,
press the "OFF" button and disconnect the power cord from the
AC power supply
Do not place beverages or liquids on or near the unit. Do not
allow foreign objects to contact the ports of sockets of the UPS.
This unit intended for installation in a controlled environment
(temperature-controlled indoor area free of conductive
contaminants). Avoid installing the UPS in locations where
there is standing or running water, or excessive humidity.
Do not plug the UPS input into any of its output sockets.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or
vacuum cleaners to UPS.
Never incinerate depleted batteries as they may explode.
MODEL
600
CAPACITY
600VA/360W
Input Voltage
220/230/240 VAC
Input Voltage Range
162-290 VAC
Output Voltage
Regulation
± 10 % (Bat. mode)
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type & No
12V/7Ahx1
Charging Time
6 hours recover to 90% capacity
Dimension (DxWxH)
300 x 101 x 142 mm
Net Weight (kgs)
4.4
Humidity
0-90% RH @ 0-40°C non-condensing)
Noise Level
Less than 40dB
*Specifications are subject to change without notice.
A battery can present a risk of electrical shock and high short
circuit current. The following precautions should be observed
when working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or
disconnecting batteries terminal.
6) Determine if battery is inadvertently grounded. If inadvertently
grounded, remove source from ground. Contact with any part
of a grounded battery can result in electrical shock. The
likelihood of such shock can be reduced if such grounds are
removed during installation and maintenance.
Internal battery is a voltage is a sealed, lead-acid, 6-cell battery.
12VDC.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required
precautions. Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and
type of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Released
electrolytes may be toxic are harmful to the skin and eyes.
ATTENTION: Risk of electric shock, Hazardous voltage may
still be present through the battery, even after disconnection of
from the main power source. Before servicing, the battery
supply should be disconnected from plus and minus poles at
the on the battery connectors inside the UPS.
To reduce the risk of overheating, do not block or cover the
UPS cooling vent. Avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space
heater or furnaces.
Unplug the UPS prior to cleaning. Avoid using liquids or
soaking wet cloth
WARNING: This is a category C2 UPS product. In a residential
environment, this product may cause radio interference, in
which case the user may be required to take additional
measures.
Problem
Possible Cause
Solutions
Nothing is
displayed on
LCD panel.
The UPS is not on.
Press the power switch
again to turn on the UPS.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Battery fault.
Replace the battery.
The UPS
always on
battery mode.
Check for a loose
power cord.
Firmly plug in the power
cord.
The UPS
beeps
continuously
Check the fault code
for the details.
Check the fault code for the
details
Backup time
too short.
Battery voltage is too
low.
Charge the battery at least
6 hours.
Overload.
Remove unnecessary loads.
Before reconnecting
equipment, please verify
that the load matches the
UPS power output
specifications.
Battery wont charge
Replace the battery.
If any abnormal situations occur that are not listed above, please
call for service immediately.
SAFETY CAUTION
SAVE THESE INSTRUCTION - This manual contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
SPECIFICATIONS
TROUBLESHOOTING


Product specificaties

Merk: V7
Categorie: UPS
Model: UPS1P600E

Heb je hulp nodig?

Als je hulp nodig hebt met V7 UPS1P600E stel dan hieronder een vraag en andere gebruikers zullen je antwoorden