Bekijk gratis de handleiding van Sussex VFM200TSXFMMIK (6 pagina’s), behorend tot de categorie Kraan. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 3.7 sterren uit 1.5 reviews. Heb je een vraag over Sussex VFM200TSXFMMIK of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/6
Product code
Voda
VFMT Floormount mixer 160mm
VFM200T Floormount mixer 200mm
VFM250T Floormount mixer 250mm
VFMHT Floormount mixer with hand held
VFMMCT Floormount mixer with curved outlet
VFMBMCT Floormount basin mixer curved
sussextaps.com.au
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003
Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.
HO T/ COLD
FE E
D CH AN
NEL
Ap p rox.
400m m
Ap pro x.
400m m
CONCRETE RECES REQUIREMENTS
FIXED AND CONNECTED VALVE BACK FILLED RECESS
FIXINF AND CONNECTIONS
(FIXING VALVE)
Voda
Fixing and connections (Fig. 2 & 3)
Back-filled recess (Fig. 4)
Existing concrete floor
New concrete floor (pre-pour)
*To install the Floormount Fixing Valve a 50mm step down (recess) is required in the concrete surface where
the floormount is to be located.
- The recess area is to be a minimum of 200 x 300mm to allow enough room for the fixing valve to be fitted.
NOTE: This can be a larger area if unsure of exact mounting position.
Important: the recess area is required to be 50mm deep and must be flat and level.
- Connect 1/2” elbows (or male/female nipples) to Fixing Valve in preparation for the hot/cold water lines.
- Postion fixing valve into concreted recess area.
NOTE: Align “Front” to face bath or wash vessel.
- Mark and drill for 8mm “dyna bolt” or other appropriate anchoring bolts (not supplied).
- Fix Floormount Fixing Valve and complete hot and cold water line connections.
- Ensure the valve is level and well anchored.
- Tighten “end caps” and perform water testing, and ensure there are no water leaks.
- Leave end caps, pressure plate and fixing bolts in the valve to protect the threads until final fit-off.
- Once all water connections are made and tested, fill in the recessed area and channelling up to the
Fixing Valve with a mortar mix.
- After mortar has set, seal the area between mortar and the Fixing Valve.
- Cut 400 x 400mm section through concrete slab where the floormount mixer is to be located (Fig. 1).
- Remove cut section and drill for the appropriate concrete ‘tie-rods’ into side walls of cavity.
- Fit ‘tie-rods’ and pour concrete to create a 50mm step down (recess) from the original concrete
floor surface (Fig. 1).
NOTE: Recess area must be flat and level.
- Hot and cold lines can be chased into the recessed area by cutting a minimum 50 x 50mm channel (Fig. 1).
*To install this floormount fixing valve, a 50mm step down (recess) is required in the concrete slab. The floormount fixing
valve is supplied with end caps, pressure plate and fixing bolts. Leave intact until final fit off with the floormount mixer.
Floormount mixer Concrete floor Rough-in
sussextaps.com.au
100mm MIN
50mm TYP
400mm
50mm
NOGGIN
JOIST
JOIST
40mm
APPROX
TILE
GLUE
WATER
PROOF
19mm
PARTICLE
BOARD
END
CAPS
M8
BOLT
NOGGIN
JOIST
JOIST
HOT
COLD
50mm
SCREW AND WASHER
(X 4) (NOT SUPPLIED)
END CAP (WITH SEAL)
FLOORMOUNT MIXER
ADAPTER PLATE
CONNECTING FITTING
FLOORMOUNT MIXER
VALVE BODYE LBOW (X2)
(NOT SUPPLIED)
COLDHOT
FRONT
FLOORMOUNT
MIXER VALVE
BASE PLATE
PRESSURE PLATE
NOGGINJOIST
JOIST
M8 X4 0 BO LT
CONCRETE RECES REQUIREMENTS
FIXED AND CONNECTED VALVE BACK FILLED RECESS
FIXINF AND CONNECTIONS (WOODEN)
(FIXING VALVE)
Voda
Floormount mixer Wooden floor Rough-in
Fixing and connections (Fig. 2 & 3)
Back-filled recess (Fig. 4)
Rough-in (Wooden floor)
- Fix a 100x50mm min noggin. 50mm below the top of the joists in the position where the floormount mixer is to
be located (Fig. 1).
NOTE: the floormount mixer has been supplied to suit a concrete installation. Some parts need to be changed to
suit a wooden floor.
- To suit wooden flooring, remove the m8x25mm bolts and the pressure plate. Using a 6mm allen key, remove the
two connection fittings (O-ring sealed) and replace with the longer version (tighten well).
- Add the Floormount Mixer Adapted Plate. Replace the Pressure Plate and loosely fit the M8x40mm bolts (Fig. 2).
NOTE: the shorter connection fittings and M8x25mm bolts will not be required.
- Add appropriate elbows or 1/2” BSP nipples to allow for hot/cold water connections (not supplied).
- Secure Floormount Mixer Valve to coggin using appropriate wood screws (not supplied).
NOTE: “FRONT” to face water vessel.
- Complete hot/cold water connections.
- Ensure the valve is level and well anchored.
- Connect 1/2” elbows (or male/female nipples) to Fixing Valve in preparation for the hot/cold water lines.
- Postion fixing valve into concreted recess area.
NOTE: Align “Front” to face bath or wash vessel.
- Mark and drill for 8mm “dyna bolt” or other appropriate anchoring bolts (not supplied).
- Fix Floormount Fixing Valve and complete hot and cold water line connections.
- Ensure the valve is level and well anchored.
- Tighten “end caps” and perform water testing, and ensure there are no water leaks.
- Leave end caps, pressure plate and fixing bolts in the valve to protect the threads until final fit-off.
- Once all water connections are made and tested, fill in the recessed area and channelling up to the
Fixing Valve with a mortar mix.
- After mortar has set, seal the area between mortar and the Fixing Valve.
sussextaps.com.au