1x Housing
Parts List
Universal
Maximum Internal Installation Depth 22.5mm (0.9”)
Maximum Internal Installation Width 70.4mm (2.75”)
Maximum Internal Installation Height 78.4mm (3.07”)
Housing Installation Depth15mm (0.6”)
Housing Material3mm (0.12”) PC/ABS (UL 94 V-0)
Intention
• Blank Low-Voltage AC/DC Power Enclosure
• Not Suitable for Drinking Water Contact
Example Installation Applications
Switches, Circuit Breakers, Outlets, Chargers,
Cable Feed-Through Port, Air Compressor
Quick-Connectors, Monitoring/Inspection
≥ IPX6 rated switches and wiring only, if nesting alongside water connections
Technical Information
Read all warnings before installation
• Cut out drilling template
• Tape to mounting surface
• Use template to drill 1x ø95mm (3 ¾”) hole and
4x appropriately sized pilot holes based on the
pilot drill table provided.
• Remove template and clean mounting surface
1
• Cut out the enclosure customisation template.
• Use template to mark out the locations for the chosen
component installation/s.
Keep 4mm minimum distance between holes drilled.
• Tape template to rear face of the housing.
• Make required installation cutouts to housing and
deburr / clean up.
• Test fit components to housing to ensure sufficient
clearance before final assembly.
2
EN WARNING
Ensure any holes cut will not significantly weaken the structure of the mounting surface.
Before drilling any holes, ensure the cutting template is correct to scale and the area behind the mounting location is clear of
wires, fuel and all other hazardous objects.
Do NOT install in a hazardous/flammable atmosphere e.g. engine room.
This product must be mounted strictly in accordance with the provided mounting template.
The IP protection rating is only valid if the installation is carried out correctly according to the instructions and on a flat, smooth
and non-porous surface.
This product is a blank enclosure designed for low-voltage electrical installations. Devices shown in this installation manual are
examples of what can be fitted to this product and are not included.
This product is not suitable for drinking water contact.
CAUTION
The IP protection rating applies to the front only and when the product lid is fully closed and not in use.
Do not leave the lid in an open position when driving/underway, this may damage the product and the mounting surface.
When choosing a mounting location, avoid areas exposed to heat radiation devices, with poor ventilation or an area that can
become submerged.
Tools Required
Drill
Drill Bit
Ø3mm (1/8”)
Silicone or
Automotive Sealant
4x Mounting Screws
PH2
Screwdriver
Holesaw
Ø95mm (3 3/4”)
MaterialPilot Drill SizeFixing
Soft Material
eg. plywood, thin metal sheet
3mm (1/8”)
Included
4x No.8 Screws
Hard Material eg. fiberglass, hardwood, acrylic3.5mm (9/64”)
Bolt-Through Mounting4.5mm (11/64”)
Recommended
Flanged M4 Panhead Bolts, Washers
and Nyloc Nuts (Not included)
Pilot Drill Table
Product Approvals
Waterproof RatingIP68, IP69K Front only when lid is closed
CertificationCE, ROHS
3
• Apply silicone/automotive sealant to the 4x No.8 PH2
Panhead mounting screws.
• Secure the housing assembly to the mounting surface
- DO NOT overtighten the screws.
• Perform any final wiring or connections required for
the fitted components.
• Note: Silicone/sealant application to the rear mounting
surface is not required, the included rear gasket meets
the stated IP-ratings when this product is installed
on a flat surface.
Installation
78.4mm (3.09")
70.4mm (2.77")
3x
R40.7mm (1.60")
Enclosure Customisation Template x2
Note: See separate insert for full drilling template
50mm
2”
�5mm
0.5”
WARNING: CHECK SCALE
This is not an external drilling template; it is a cutting guide for your chosen electrical
or utility accessories.
i
Accessory Height Limit
Maximum height of the accessory for the lid to seal properly is 22.5mm (0.9”).
i
Roam Series
Universal Electrical and Utility Housing
Installation Instructions
SC-R-U1
scanstrut.com
EN
DE
ES
FR
IT
SWE
READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
LESEN SIE DIESE ANLEITUNG DURCH, BEVOR SIE MIT DER INSTALLATION BEGINNEN
LEA ESTAS INSTRUCCIONES ANTES DE INSTALAR EL PRODUCTO
VEUILLEZ PRENDRE CONNAISSANCE DE CES INSTRUCTIONS. AVANT DE PROCÉDER
À L’INSTALLATION
LEGGERE QUESTE ISTRUZIONI PRIMA DI INSTALLARE IL PRODOTTO
LÄS DESSA INSTRUKTIONER INNAN PRODUKTEN INSTALLERAS
This product does not contain any user serviceable parts. DO NOT attempt to repair or modify the product in any way other than
the specified installation steps.
INSTALLATION
Professional installation recommended.
Care should be taken to ensure devices have sucient clearance within the housing before committing to making installation cuts.
ENVIRONMENTAL PROTECTION
Waste electrical products fitted to this housing should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for recycling advice.
IMPORTANT
The lid must remain securely latched closed when not in use. Scanstrut Ltd & Inc. accepts no liability for any product malfunction
due to the lid being left open when not in use.
Scanstrut Ltd & Inc. accepts no responsibility for any injuries or other damages arising from the use of their products in any
circumstances.
WARRANTY
A 3 year, non-transferable warranty covers this Scanstrut product only and not any devices that are powered by it.
No warranty is given for users’ devices. Users expose their devices to hazards, known or unknown, at their own risk.
UK / EMEA / APAC
Scanstrut Ltd, 14 Dart Business Park,
Clyst St. George, Exeter, EX3 0QH
USA
Scanstrut Inc. 7 Pequot Park Rd,
#303 Westbrook, CT 06498
For the latest tech info visit
scanstrut.com
EU Representative (Regulatory Inquiries Only)
Eucomply OÜ, Pärnu mnt 139b-14, 11317 Tallinn, Estonia
hello@eucompliancepartner.com +33 757690241
RevA RETAIL-INST-007624
TOP ^
78.4mm (3.09")
70.4mm (2.77")
3x
R40.7mm (1.60")
TOP ^
Product specificaties
| Merk: | Scanstrut |
| Categorie: | Niet gecategoriseerd |
| Model: | SC-R-U1 |
Heb je hulp nodig?
Als je hulp nodig hebt met Scanstrut SC-R-U1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Scanstrut
8 September 2026
8 September 2026
8 September 2026
7 September 2026
7 September 2026
23 Mei 2026
27 Augustus 2025
27 Augustus 2025
26 Augustus 2025
26 Augustus 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
8 September 2026
8 September 2026
8 September 2026
8 September 2026
8 September 2026
8 September 2026
8 September 2026
8 September 2026
8 September 2026
8 September 2026