Product Approvals
Waterproof RatingIP68, IP69K Front only when lid closed
CertificationsCE, FCC, C-Tick, ROHS, WEEE
Tools Required
Drill
Holesaw
Ø95mm (3 3/4”)
Drill Bit
Silicone or
Automotive Sealant
1x Housing
Parts List
4x Mounting Screws
MaterialPilot Drill SizeFixing
Soft Material
eg. plywood, thin metal sheet
3mm (1/8”)
Included
4x No.8 Screws
Hard Material eg. fiberglass, hardwood, acrylic3.5mm (9/64”)
Bolt-Through Mounting4.5mm (11/64”)
Recommended
Flanged M4 Panhead Bolts, Washers
and Nyloc Nuts (Not included)
Pilot Drill Table
Technical Information
• Cut out drilling template
• Tape to mounting surface
Use template to drill 1x ø95mm (3 ¾”) hole and 4x appropriately sized pilot holes
based on the pilot drill table provided.
Remove template and clean mounting surface
1
PH2
Screwdriver
Battery Cable
Crimping Tool
Dual USB-C
Input Voltage (12/24V System)10-32V DC
Input Current Max6A
Output Type C (12V System)5V3A, 9V3A, 12V3A Max
Output Type C (24V System)5V3A, 9V3A, 12V3A, 15V3A, 20V3A Max
Standby Power Draw0.01W
SAT Connection
Connection TypeDual F-Type Coaxial
Dual F-Type CoaxialNickel-Plated Brass
Impedance75Ω
ApplicationsSatellite & TV Systems
12V Power Outlet
Input Voltage (12V System)10-15V DC
Input Current Max15A
Output Max225W
15A/225W: 30 Mins Max
Roam Series
Multi-Power Outlet • 12V Power
Dual USB-C • Anderson 50A • SAT
Electrical Information
& Installation Instructions
SC-R-M1
scanstrut.com
EN
DE
ES
FR
IT
SWE
READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
LESEN SIE DIESE ANLEITUNG DURCH, BEVOR SIE MIT DER INSTALLATION BEGINNEN
LEA ESTAS INSTRUCCIONES ANTES DE INSTALAR EL PRODUCTO
VEUILLEZ PRENDRE CONNAISSANCE DE CES INSTRUCTIONS. AVANT DE PROCÉDER
À L’INSTALLATION
LEGGERE QUESTE ISTRUZIONI PRIMA DI INSTALLARE IL PRODOTTO
LÄS DESSA INSTRUKTIONER INNAN PRODUKTEN INSTALLERAS
Anderson 50A DC Connection
Connection TypeAnderson SB50 - Grey
Compatible ConnectorAnderson SB50 - Black, Grey
Connector Max CurrentRated 50A (6AWG cable)
Connector Max VoltageRated 600V DC
Max Power Delivery (12V System)600W
Max Power Delivery (24V System)1200W
Max Power Delivery (48V System)2400W
SB50 terminal crimps are included. Only genuine Anderson Power connectors and terminal crimps not
should be used with this product and are available from Anderson Power.
Sizes available:
• 6AWG/16mm² (Part number - 5900)
• 8AWG/10mm² (Part number - 5952)
• 12-10AWG/4mm²-6mm² (Part number - 5915)
Read all warnings before installation
Installation
UK / EMEA / APAC
Scanstrut Ltd, 14 Dart Business Park,
Clyst St. George, Exeter, EX3 0QH
USA
Scanstrut Inc. 7 Pequot Park Rd,
#303 Westbrook, CT 06498
For the latest tech info visit
scanstrut.com
EU Representative (Regulatory Inquiries Only)
Eucomply OÜ, Pärnu mnt 139b-14, 11317 Tallinn, Estonia
hello@eucompliancepartner.com +33 757690241
RevA RETAIL-INST-007595
Apply silicone/automotive sealant to the 4x No.8 PH2 Panhead
mounting screws.
Secure the housing assembly to the mounting surface -
DO NOT overtighten the screws.
Note: Silicone/sealant application to the rear mounting surface is
not required, the included rear gasket meets the stated IP-ratings
when this product is installed on a flat surface.
Note: For ease of access, the following steps are the
recommended order of installation for each product utility.
2
3
Select installation cable gauge according to expected input voltage and current
for your specific Anderson SB50 usage.
Using a suitable battery cable crimping tool, crimp chosen size of Anderson SB50
terminal crimps (not included) onto installation cables.
Fully push the terminal crimps in the correct orientation into the housing connector
from the rear, as per Anderson assembly instructions. The terminal crimps will click
into place if installed correctly.
Connect to battery system. Suitable fuse and isolator switch installation
recommended. Professional electrician installation highly recommended.
+
-
CLICK!
CLICK!
DOWN
UP
Route F-type coaxial cable (RG6 type recommended)
between TV/receiver and the housing, then connect to
corresponding input type (cable and satellite).
It is advisable not to route directly alongside electrical
cables, to prevent signal interference occurring.
Professional installation highly recommended.
It is possible that TV signal interference may occur if using
all utilities simultaneously. If this is the case, it’s advisable to
disconnect one utility at a time to identify which is causing
the interference and consider re-routing the wiring.
4
TV SAT INPUT
TV CABLE INPUT
PARK CABLE OUTPUT
RV SATELLITE
Connect the Dual USB-C socket to a 12/24V supply
(ensuring a waterproof connection).
Fuse and select cable diameter according to input voltage
and 6A maximum input current for your specific installation.
6
If using a 24V system, a voltage converter
is required
Connect the 12V power outlet to a 12V supply (ensuring a waterproof
connection). (Example installation diagram shown).
Fuse and select cable diameter according to input voltage and current for your
specific installation. 15A max input current.
To ensure device compatibility with this product:
The minimum barrel length of device plugs to be used with this product is
44mm (1.73”).
This is measured between the end of the barrel at the sprung positive
terminal pin, up to the point at which the barrel begins to widen.
5
44.0mm(1.73")
Minimum