Panasonic WH-ADC0309J3E5ANC Handleiding

Panasonic Airco WH-ADC0309J3E5ANC

Lees hieronder de 📖 handleiding in het Nederlandse voor Panasonic WH-ADC0309J3E5ANC (84 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/84
Operating Instructions
Air-to-Water Hydromodule + Tank
Model No.
Indoor Unit
WH-ADC0309J3E5ANC
Outdoor Unit
WH-UD03JE5*
WH-UD05JE5*
WH-UD07JE5*
WH-UD09JE5*
ACXF55-28330
Manufactured by:
Panasonic AVC Networks Czech, s.r.o.
U Panasoniku 1, 320 84 Plze , Czech Republicň
Operating Instructions
Air-to-Water Hydromodule + Tank 2-39 English (EN)
Betjeningsvejledning
Luft-til-vand hydromodul + Tank 40-77 Dansk (DA)
2
Table of contents
Safety precautions .......................................................4-16
Remote Controller buttons and display .....................17-19
Initialization .....................................................................19
Quick Menu ....................................................................20
Menus ........................................................................20-34
For user
1 Function setup ...................................................20-21
1.1 Weekly timer
1.2 Holiday timer
1.3 Quiet timer
1.4 Room heater
1.5 Tank heater
1.6 Sterilization
1.7 DHW mode
2 System check ......................................................... 22
2.1 Energy monitor
2.2 System information
2.3 Error history
2.4 Compressor
2.5 Heater
3 Personal setup ...................................................22-23
3.1 Touch sound
3.2 LCD contrast
3.3 Backlight
3.4 Backlight intensity
3.5 Clock format
3.6 Date & Time
3.7 Language
3.8 Unlock password
4 Service contact .......................................................23
4.1 Contact 1 / Contact 2
For installer
5 Installer setup > System setup ..........................24-29
5.1 Optional PCB connectivity
5.2 Zone & Sensor
5.3 Heater capacity
5.4 Anti freezing
5.5 DHW capacity
5.6 Buffer tank connection
5.7 Base pan heater
5.8 Alternative outdoor sensor
5.9 Bivalent connection
5.10 External SW
5.11 Solar connection
5.12 External error signal
5.13 Demand control
5.14 SG ready
5.15 External compressor SW
5.16 Circulation liquid
5.17 Heat-Cool SW
5.18 Force heater
5.19 Force defrost
5.20 Defrost signal
5.21 Pump owrate
6 Installer setup > Operation setup ......................29-33
6.1 Heat
6.2 Cool
6.3 Auto
6.4 Tank
7 Installer setup > Service setup ..........................33-34
7.1 Pump maximum speed
7.2 Pump down
7.3 Dry concrete
7.4 Service contact
Cleaning instructions ......................................................35
Troubleshooting .........................................................36-37
Information .................................................................38-39
Thank you for purchasing Panasonic product.
Before operating the system, please read these operating instructions thoroughly and keep them for future reference.
Installation Instructions attached.
Serial number and production year please refer to name plate.
EN
3
Operating conditions
HEATING (TANK) HEATING (CIRCUIT) *1, *2 COOLING (CIRCUIT)
Water outlet temperature (°C)
(Min. / Max.) - / 65*320 / 55 (Below Ambient -15 °C) * 4
20 / 60 (Above Ambient -10 °C) *45 / 20
Outdoor ambient temperature (°C)
(Min. / Max.) -20 / 35 -20 / 35 10 / 43
When the outdoor temperature is out of the range in the table, the heating capacity will drop signi cantly and the outdoor unit may
stop operating for its protection.
The unit will restart automatically after the outdoor temperature returns to the speci ed range.
*3 Above 55 °C, only possible with backup heater operation.
*4 Between outdoor ambient -10 °C and -15 °C, the water outlet temperature gradually decreases from 60 °C to 55 °C.
Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions.
Panasonic Air-to-Water is a split system, consisting of two units: indoor and outdoor units. The indoor unit consist of the
hydromodule and 200L sanitary water tank.
These operating instructions describe how to operate the system using the indoor and outdoor units.
As for the operation of other products such as radiator, external thermo controller, and under oor units, refer to the operating
instructions of each product.
System could be locked to operate in HEAT mode and disable COOL mode.
Some functions described in this manual may not be applicable to your system.
Must use water that complies with European water quality standard 98/83 EC. The lifespan of the Tank Unit will be shorter if
groundwater (include spring water and well water) is used.
The Tank Unit shall not be used with the tap water containing contaminants such as salt, acid, and other impurities which may
corrode the tank and its component.
Consult your nearest authorised dealer for further information.
*1The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service
partners.
*2Only displayed when COOL mode is unlocked (This means when COOL mode is available)
System overview
Radiator
Shower
Fan Coil
Unit
Floor
Heating
Outdoor Unit
Solar Panel
Power Supply
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
Note:
Not recommended to open the Front Plate.
(For authorised dealer/specialist use only)
Indoor Unit
Remote Controller
Front Plate


Product specificaties

Merk: Panasonic
Categorie: Airco
Model: WH-ADC0309J3E5ANC

Heb je hulp nodig?

Als je hulp nodig hebt met Panasonic WH-ADC0309J3E5ANC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Panasonic

Handleiding Airco

Nieuwste handleidingen voor Airco