Bekijk gratis de handleiding van Intermatic T102 (1 pagina’s), behorend tot de categorie Schakelaar. Deze gids werd als nuttig beoordeeld door 28 mensen en kreeg gemiddeld 4.3 sterren uit 14.5 reviews. Heb je een vraag over Intermatic T102 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/1

MODEL: T102
24 HOUR DIAL TIME SWITCH
TYPE 1 INDOOR USE ONLY
SINGLE POLE SINGLE THROW (SPST)
40 A RESISTIVE, INDUCTIVE, TUNGSTEN
OR 1000 VA PILOT DUTY 120-277 VAC;
2 HP (24 FLA) - 120 VAC; 5 HP (28 FLA) - 240 VAC
16 A ELECTRONIC BALLAST, 277 VAC
PROGRAMMING INSTRUCTIONS
1. TO SET “ON” AND “OFF” TIMES: Hold trippers against edge of CLOCK-
DIAL ON OFF, pointing to time (AM or PM) when and operations are desired,
tighten tripper screws firmly. For additional tripper pairs on CLOCK-DIAL
order 156T1978A.
2. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction
and align the exact time-of-day on the (the time now, when CLOCK-DIAL
switch is being put into operation) to the pointer. DO NOT MOVE POINTER.
OPERATING INSTRUCTIONS
•
TO OPERATE SWITCH MANUALLY: MANUAL LEVERMove
CLOCK-below
DIAL left or right as indicated by arrows. This will not effect next operation.
• IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day.
See programming instructions.
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE WIRE
INSULATION CLEARS
PRESSURE PLATE
MINIMUM
COPPER
WIRE SIZE
(AWG)
MAX.
LOAD
(AMP)
MIN.
INSUL-
ATION
TEMP(°C)
75°C INSULATION MAX. MOTOR
LOAD (HP)
SINGLE PHASE
3 PHASE
120 V. 240 V. 208 V.
240 V.
14
12
10
8
15
20
30
40
90
90
90
90
1/2
1
2
-
2
2 1/2
3
5
N/A
N/A
CLOCK MOTOR: 208-277 VAC, 60 HZ.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO
ORDER REPLACEMENT, INDICATE PART NO. (WG--) ON MOTOR COVER.
WARNING
Risk of Fire or Electric Shock
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
• Installation and/or wiring must be in accordance with national and local electrical code requirements.
• Use wires rated at least 90°C - COPPER conductors ONLY.
• Replace plastic insulator covering terminals before powering ON.
• KEEP DOOR CLOSED AT ALL TIMES when not servicing.
NOTICE
• Rotate timer dial clockwise only.
• Do not move the clock hands on the timer. Moving the clock hands can damage the timer.
AVERTISSEMENT
Risque d’incendie ou de choc électrique
• Utiliser des fils classés 90°C minimum - Conducteurs en CUIVRE UNIQUEMENT.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
154--01998
UL
HOLOGRAM
LABEL
LR3730
WIRING INSTRUCTIONS: Remove 1/2 inch of insulation from wire ends. Tighten terminal screws firmly
(2-18 in-lbs). Use solid or stranded COPPER only. May use two wires of the same size and type.conductors
TIME
POINTER
TIME
DIAL
OFF
TRIPPER
MANUAL
LEVER
ON
TRIPPER
LINE 1
LINE 2
CLOCK
MOTOR
GROUND
A
1
2
GRD.
208
THRU
277V
SUPPLY
TO
LOAD
WIRING
DIAGRAM
FOR 208 OR 277 V SUPPLY. CONNECT
LINE 1 TO TERMINAL “A”.
Product specificaties
Merk: | Intermatic |
Categorie: | Schakelaar |
Model: | T102 |
Heb je hulp nodig?
Als je hulp nodig hebt met Intermatic T102 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Schakelaar Intermatic
30 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
Handleiding Schakelaar
- WHALE
- Brilliant
- Hama
- Ubiquiti Networks
- Doepke
- Jabra
- Setti+
- Tripp Lite
- Grasslin
- Hikvision
- Abus
- Totolink
- ConnectPro
- Panasonic
- SmartAVI
Nieuwste handleidingen voor Schakelaar
30 Juli 2025
30 Juli 2025
30 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025
29 Juli 2025