Lancom XS-6228QF Handleiding


Pagina's 1 Schakelaar

Bekijk de handleiding van Lancom XS-6228QF gratis online of download de PDF. Deze handleiding is 1 keer bekeken. Vraag over dit model? Stel een vraag

Hereby, Rohde & Schwarz Networks and Cybersecurity GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance
with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at
www.rohde-schwarz.com/networks-and-cybersecurity under ‚Service & Support → Online documentation → Compliance & product certications‘.
Mounting & connecting
LED description & technical details
Hardware Quick Reference
Rohde & Schwarz Networks and Cybersecurity
R&S®LANCOM XS-6228QF
R&S and Rohde & Schwarz are trademarks of Rohde & Schwarz GmbH & Co. KG, registered or used, among others, in Germany, the EU, the USA, China, and other countries. Other names or designations used may be registered trademarks of different
companies or owners. This document contains forward-looking statements regarding products and product features. The publisher reserves the right to change these at any time without stating reasons. No liability is accepted for technical inaccuracies
or omissions. 112371 / 0826
Before initial startup, please make sure to take notice of the information regarding the intended use in the
Operate the device only with a professionally installed power supply at a nearby power socket that is freely
accessible at all times.
The power plug of the device must be freely accessible.
Please note that support for third-party accessories (SFP and DAC) is not provided.
Hardware
Power supplyExchangeable power supply (110-230 V, 50-60 Hz)
Power consumptionmax. 105 watts
EnvironmentTemperature range 0–40°C, humidity 10–90%; non-condensing
HousingRobust metal housing, 19“ 1U (442 x 44 x 375 mm > W x H x D), network connectors on the front
Number of fans2 exchangeable fan modules
Interfaces
SFP-DD4 SFP-DD (25 / 50 Gbps) stacking ports
QSFP+ / SFP282 QSFP+ (40 Gbps) / 4 * SFP28 (10 / 25 Gbps) FleX uplink ports for connecting higher-level core switches, content servers,
or data centers
SFP+ / TP-Ethernet
Combo-Ports
Each 4 SFP+ (1 / 10 Gbps) / TP-Ethernet (1 / 2.5 / 5 / 10 Gbps) combo ports for use as additional downlink ports or for
connection to a NAS or router
SFP+16 SFP+ (1 / 10 Gbps) downlink ports for aggregation of subordinate access switches
Console1 RJ-45 / 1 Micro USB
USB1 USB
OOB-Management1 RJ-45
Package Content
Mounting materialRack mounting system consisting of 2 mounting brackets for front mounting and 2 slide-in rails for optional rear mounting of
the switch in the rack.
Power supply1 exchangeable power supply LANCOM SPSU-250, expandable to 2 LANCOM SPSU-250 power supplies
(hot swappable, for redundancy operation)
Fan modules2 fan modules LANCOM SFAN-XS6, already mounted
Cables1 IEC power cord, 1 serial conguration cable, 1 micro USB conguration cable
🄰 System / Fan / Stack
System: greenDevice operational
System: redSystem error, please check syslog /
error log
Fan: redFan error
Stack: offNo connection
Stack: greenAs master device: port activated and connected to
slave device
Stack: orangeAs slave device: port activated and connected to
master device
🄱 Reset button
~5 sec. pressedDevice restart
Pressed until all
port LEDs glow
Conguration reset and device restart
🄲 SFP+ ports 1G / 10 G
OffPort inactive or disabled
GreenLink 10 Gbps
Green, blinkingData transfer, link 10 Gbps
OrangeLink 1 Gbps
Orange, blinkingData transfer, link 1 Gbps
🄳 SFP+ ports 1G / 10G (combo ports)
OffPort inactive or disabled
GreenLink 10 Gbps
Green, blinkingData transfer, link 10 Gbps
OrangeLink 1 Gbps
Orange, blinkingData transfer, link 1 Gbps
🄴 TP Ethernet ports 1G / 2.5G / 5G / 10G (combo ports)
OffPort inactive oder disabled
Green left / rightLink 10 Gbps / 1 Gbps
Green, blinking left / rightData transfer, link 10 Gbps
/ 1 Gbps
Orange left
/ right
Link 2.5 / 5 Gbps
Link 100 Mbps
Orange, blinking left / rightData transfer, link 2.5 / 5 Gbps
Data transfer, link 100 Mbps
🄵 SFP28 ports 1G / 10G / 25G (FleX ports)
OffPort inactive oder disabled
GreenLink 25 / 10 Gbps
Green, blinkingData transfer, link 25 / 10 Gbps
OrangeLink 1 Gbps
Orange,blinkingData transfer, link 1 Gbps
🄶 QSFP+ ports 40G (FleX ports)
OffPort inactive or disabled
GreenLink 40 Gbps
Green, blinkingData transfer, link 40 Gbps
🄷 SFP-DD stacking ports 25G (SFP28) / 50G
OffPort inactive or disabled
GreenLink 50 Gbps
Green, blinkingData transfer, link 50 Gbps
OrangeLink 25 / 10 Gbps
Orange,blinkingData transfer, link 25 / 10 Gbps
🄸 Power supply unit LED
OffNo primary voltage supply
GreenSecondary voltage supply OK
OrangeCritical power supply event that causes a shutdown:
▶OCP
▶OVP
▶fan failure
In case of parallel primary voltage supply by second
power supply unit:
▶power cable disconnected or power failure
Orange, blinkingPower supply warning event in which the power
supply continues to operate:
▶high temperature
▶high power
▶high current consumption
▶slow fan
➀
➁
Conguration interfaces RJ-45 & micro USB (Console)
Connect the conguration interface via the included serial conguration cable to the serial interface of ➀
the device you want to use for conguring / monitoring the switch. Alternatively use the interface
➁ with
a suitable micro USB cable.
➂
USB interface
Connect a USB stick to the USB interface to store general conguration scripts or debug data. You can also
use this interface to upload a new rmware.
➃
OOB interface
Use an Ethernet cable to connect this out-of-band service port for an IP interface independent of the
switching plane for management tasks or connection to a monitoring server. In particular, this port can be
used as a VPC-keepalive link (split-brain detection).
➄
SFP+ interfaces 1G / 10G
Insert suitable R&S®LANCOM SFP transceivers into the SFP+ interfaces 1 to 12. Choose cables which are
compatible with the SFP transceivers and connect them as described in the SFP transceivers mounting
instructions.
➅
SFP+ interfaces 1G / 10G (combo ports)
Insert suitable R&S®LANCOM SFP transceivers into the SFP+ interfaces 13 to 14. Choose cables which
are compatible with the SFP transceivers and connect them as described in the SFP transceivers mounting
instructions.
➆
TP Ethernet interfaces 1G / 2.5G / 5G / 10G (combo ports)
Connect the interfaces 13 to 14 via Ethernet cables to your PC or a LAN switch.
➇
SFP28 interfaces 10G / 25G (FleX ports)
Insert suitable R&S®LANCOM SFP28 or 10G SFP+ transceivers into the SFP28 interfaces 21 to 24. Choose
cables which are compatible with the SFP28 / 10G SFP+ transceivers and connect them as described in the
SFP transceivers mounting instructions.
➃
QSFP+ interfaces 40G (FleX ports)
Plug suitable R&S®LANCOM QSFP+ transceivers into the QSFP+ interfaces 21 to 22.
Select cables suitable for the QSFP+ transceivers and connect them as described in the
SFP modules mounting instructions.
Rear panel:
SFP-DD interfaces 25G / 50G
Insert R&S®LANCOM SFP-DD-DAC50 stacking cables into the SFP-DD interfaces 25
to 28. For decentralized stacking scenarios (stack-member switches are distributed
over spatially separated locations) the use of R&S®LANCOM SFP28 transceivers is
recommended.
2 slots for fan modules
To remove a fan module in case of defect, loosen the two knurled screws of the module and remove the module from the plug-in unit. To
install a new fan module, push it into the corresponding slot. Fasten the module to the switch housing with the knurled screws. Please note
that a defective fan should be replaced within 48h.
10
Power supply module with mains connection socket (rear panel).
Supply the device with power via the power supply socket of the power supply module. Use the supplied power cord or a country-specic
R&S®LANCOM power cord.
To remove the power supply module, disconnect the module from the power supply and then pull the plug out of the module. While
pressing the release lever
13
to the left, you can pull the module out of the device by the handle
12
.
11
Additional slot for power supply module with mains connection socket (rear panel).
To install an additional power supply module, remove the corresponding module bay cover by loosening both associated screws and push
the power supply module in as far as it will go until the release lever
13
audibly engages. Check by pulling the handle
12
that the module
cannot be removed from the bay without the release lever
13
being pressed to the left.
Please observe the following when setting up the device
▶Do not rest any objects on top of the device and do not stack multiple devices.
▶Keep the ventilation slots of the device clear of obstruction.
▶Mount the device with the enclosed rack mounting system in a free 19” slot of an appropriate server rack.
Both slide-in rails are attached as shown in the accompanying installation instructions.
🄳🄲
🄰
🄱
🄵🄴🄶
🄷🄸
➀➁➂➃
➄➆
➅➈
➇
11
12
10
13

Beoordeel deze handleiding


Product specificaties

Merk: Lancom
Categorie: Schakelaar
Model: XS-6228QF

Heb je hulp nodig?

Als je hulp nodig hebt met Lancom XS-6228QF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden