Honeywell CT30 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell CT30 (16 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 61 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
CT30/CT33
Low-voltage Thermostat
Owner’s
Manual
Getting started
Before you begin, make sure you have:
• Screwdriver
• Hammer
Level (optional)
• Pencil
Drill bit (3/16” for drywall, 7/32” for plaster)
Caution cardWire labels
Wall anchors and
mounting screws
(2 each)
CT30/CT33 thermostat Cover plate
Check to make sure your package includes the following items:
® U.S. Registered Trademark. Patents pending.
Copyright © 2005 Honeywell International Inc.
All rights reserved.
Owner’s Manual
2
Remove your old thermostat
1TTuurrnn ooffff ppoowweerrat heating/cooling system (or fuse/circuit-breaker panel).
2 Remove cover and thermostat, but leave wallplate with wires attached.
Old thermostat
Leave wallplate in place Is there a sealed tube containing mercury?
If so, see mercury notice below.
Cover
MERCURY NOTICE: Do not place your old thermostat in the trash if it contains
mercury in a sealed tube. Contact your local waste management authority for
instructions regarding recycling and proper disposal.
Did you purchase right thermostat? Count wires to check.
Count the number of wires coming out of the wall and attached to terminals in
your old thermostat. If any of them are attached to a terminal marked “C” or “C1”
do not count that wirein your total.
If the total (not counting C or C1) is 2 wires, proceed to the next page. If you have
3 or more wires, your new thermostat may not be compatible with your system.
Stop installation and call 1-800-468-1502 for advice.
Do you have 3 or more wires? If so, stop now.
You may have purchased the wrong replace-
ment thermostat.
CT30/CT33 Low-voltage Thermostat
3
Label wires and remove old wallplate
Use a screwdriver to disconnect wires one by one.As you disconnect each wire,
wrap it with the label matching the letter on your old thermostat. (Adhesive labels
are supplied in your thermostat package.)
Remove the old wallplate only after all wires are labeled. Be careful not to let
loose wires fall into the wall opening.
Wrap supplied labels securely around each wire
Do not let wires fall into wall opening!
IGNORE WIRE COLORS: Use only letter designations
to identify wire types.
Mark mounting position
1Level base or cover plate
if desired.
2Mark positions of
both screw holes.


Product specificaties

Merk: Honeywell
Categorie: Thermostaat
Model: CT30

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell CT30 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Honeywell

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat