Vemer TUO GO WI-FI Handleiding


Pagina's 1 Thermostaat

Bekijk de handleiding van Vemer TUO GO WI-FI gratis online of download de PDF. Deze handleiding is 1 keer bekeken. Vraag over dit model? Stel een vraag

The blue backlighting of the display during normal operation
is on but can be turned off if the installation requires it
(for example in bedrooms).
In this condition, the thermostat continues to work normally
and the backlighting turns on when you enter the setpoint
modification, advanced programming, pin insertion.
Display backlighting
9
Switch off
4
DEVICE DESCRIPTION
10
CONFIGURATION
5
DEVICE RESET
Receiving a command
Off operation
Active load
Measured temperature
Local active operation. In this state the device is disconnected from the Cloud Vemer
and any change in operation must be made using the keys on the thermostat.
Local operation can be disabled by the app.
Active keypad lock
Vemer Cloud connection active
DIMENSIONS
2
130
85
28
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
V3IS01219-010
Mod.TUO GO Wi-Fi
Manuals
download
PDF
3
CONNECTION DIAGRAM
NC
L
N
C
NO
8
REMOTE CONTROL CONFIGURATION
To configure the device using a smartphone proceed as follows:
• Create a Vemer account:
1. Install and launch the Clima Vemer App on your smartphone (or tablet)
2. Choose and fill in the “e-mail” and “password” fields“REGISTER NOW”
Note: for security reasons, it is advisable to choose a password different
from the one used to access your e-mail inbox
3. Check your e-mail address: confirm account activation by clicking on the
link contained in the e-mail sent by the system
4. Log in by entering the e-mails and passwords chosen during registration
• Start the device configuration procedure on the App by carefully
following the step-by-step instructions in the wizard
1
User Manual
WALL-MOUNTED WI-FI TOUCH SCREEN THERMOSTAT
Read all the instructions carefully
Wi-Fi wall-mounted thermostat suitable for temperature regulation with mains power supply.
The device can be managed using the App, which is available for iOS and Android systems.
Switching on the system and changing the operating settings are all operations that can be
carried out easily and from anywhere thanks to the integrated Wi-Fi module that connects the
device to the Internet through the home router. TUO GO Wi-Fi is an electronic device that
perform actions of 1B type and are intended to operate in environments with III overvoltage
category and pollution degree 2 in accordance with EN 60730-1 standard.
Code Model Description
VE801100 Tuo GO Wi-Fi Bianco Wi-Fi Wall-Mounted Thermostat, white
VE801200Tuo GO Wi-Fi Nero Wi-Fi Wall-Mounted Thermostat, black
SAFETY WARNINGS
During the installation and the operation of the instrument it’s necessary to observe
the following instructions:
1) The instrument must be installed by a qualified person by observing scrupulously the
connection diagrams.
2) The instrument must be installed and activated in compliance with current electric
systems standards.
3) After installation, inaccessibility to the connection terminals without appropriate tools
must be granted.
4) Do not use the instrument for other purposes different from the one specified.
5) In the power supply network a bipolar disconnection must be present.
6) A protection device against over-currents should be installed in the electrical system,
upstream of the device.
7) Before accessing the connection terminals, verify that the leads are not live.
8) Do not power on or connect the instrument if any part of it is damaged.
TECHNICAL CHARACTERISTICS
• Power supply: 230 Vac ±15% 50/60 Hz
• Output: bistable relay with changeover contact 5 A / 250 Vac
• Weekly programming via app with 3 settable temperatures: T1, T2, T3
• Daily resolution: 1h
• Delayed start-up can be set between 15, 30 or 45 minutes (independent for each hour)
• Measured and : 0,1°C displayed temperature resolution
• Temperature measuring range: 0 ÷ 50 °C
• Display backlight
• with total or partial password for installation in public placesKeypad lock
• Wall installation (or covering the box 503)
• Terminal block for cables with section of 1.5 mm
2
• Bluetooth comunication interface BLE
• Bluetooth operatin frequency band: 2400-2483,5 MHz
• Maximum Bluetooth radiofrequency power trasmitted: 20 dBm
• Wi-Fi operating frequency band: 2,4 GHz IEEE 802.11 b/g/n
• Maximum Bluetooth radiofrequency power trasmitted: 18,3 dBm
• Operating temperature: 0 ÷ 50°C
• Operating humidity: 20% ÷ 90% non condensing
• Storage temperature: -20 ÷ 65 °C
• Degree of protection: IP40
• Insulation: reinforced between accessible parts (front) and all other terminals
6
INSTALLATION
4
5
click
12
3
Open the door of the terminal compartment
Connect the load and the power supply (see connection diagram) and fix the device to the wall
Close the door of the terminal compartment
Place the front part on the wall-mounted part, ensuring the correct connection of the two parts
Close the device by rotating the front panel downwards
7
WARNINGS AND PRELIMINARY OPERATIONS FOR THE
CORRECT POSITIONING AND CONNECTION OF THE DEVICE
WARNINGS
The use of the thermostat via APP must be carried out in the presence
of a Wi-Fi network connected to the Internet.
The smartphone used for setup must be connected to the same Wi-Fi network.
Make sure you have a Vemer account available.
• Install and connect the device in accordance with the installation instructions in this manual.
• The device can be installed on the wall or to cover the 3-module flush-mounting box (type 503).
• It is advisable to install the device at a height of 1.5 metres from the floor, in an area that reflects the
average temperature conditions of the room as closely as possible.
• Avoid installation near doors or windows, in niches, behind doors and curtains or in positions with direct
radiation and/or excess or total lack of ventilation.
• Ensure that the Wi-Fi signal is such as to ensure stable communication
Local operation is indicated by the icon on the App and device display, and can be paused and/or
disabled at any time from the App (but not from the device).
If local operation is disabled (useful if you only want to control the device from the App), the icon
will
appear on the display and if you try to access the configuration menus from the device’s keypad, you
will not be able to make any changes..
Setpoint modification
Keypad unlock
When the key lock is active, the device adjusts the humidity using the set programming.
In this condition, after pressing a key, the display shows the word “
BLOC
”
To unlock the keypad:
1. When the word “
BLOC
” is displayed, press and hold any of the four keys until the display
shows “--”.
2. Enter the correct password with the keys and confirm with the key and .
The keypad remains unlocked for approximately 45 seconds after the last key is pressed,
after which the keypad reactivates the lock. (To remove the key lock, see BOX 10)
In the event that the device cannot reach the Vemer Cloud due to connectivity problems, the
LOCAL OPERATION allows complete management and configuration of the humidistat through its
keypad. In this way, the device does not check for new settings on the Cloud and adjusts the humidity
according to the settings entered from the keypad (the programming and configuration in the Cloud are
not changed).
Note: In off mode it is not possible
to access the setpoint
modification.
In the ADV menu, the parameters related to the advanced configuration of the device are proposed in
sequence. Press:
• the keys
and to change the value of the selected parameter
• the key
to go to the next parameter
• the key
to exit and confirm the changes
Note: the device exits the menu after about 40 seconds without any key being pressed.
ADV MENU - ADVANCED PARAMETERS SETTING
Normal
operation
o
desired
temperature
setting
Normal
operation
load on ( )
SET
Normal
operation
Off
operation
To reset if the key lock is active and you do not know the unlock password, you must
remove and re-apply the power and, when the display shows all segments, hold down
the key until “DEF” appears.
Perform a reset to erase the entered settings and return the unit to the factory
settings.To reset:
1. from the initial screen, press and hold the key
to access the confi guration menu.
2. keep the keys pressed at the same time and until “
RES
”. appears on the display.
3. when the display shows all segments, press and hold the key ” appears until “DEF
Operating mode
Heating
(winter)
Regulation tyoeon/o
Di erential (on/o )0,3 °C
Band (proportional)0,5 °C
Period (proportional)10 minutes
Antifreeze temperature OFF6 °C
Adj. ADJ temperature 0 °C
Min. settable temperature2 °C
Max. settable temperature50 °C
Hour meter operation
/
0 h
Retroilluminazioneactive
Key lock passworddeactivated
+
Initial screen
SET
3s3s
SET
3s
Configuration
menu
Normal
operation
SET
3s
ADV menù
Adjustment of the measured temperature
Under certain installation conditions, the temperature measured by the unit
may differ from the average room temperature. In this case, enter a
temperature adjustment using the ADJ menu.
Allowed values: -5°C ÷ 5°C Factory value: 0 °C.
Note: the temperature value displayed on the display during normal operation
includes any adjustment made.
Wi-Fi Connection Setup
From this menu, you can always choose whether to enable/disable WiFi remote
control mode. Select
on
to enable WiFi remote control or
Off
to disable it.
Factory value:
on
WiFi menu and De-Link (active only with remote control enabled)
This sub-menu consists of 3 different screens and described below.
To switch from one screen to another, use the keys and .
• the intensity of the signal between the device and the router (FLd).
For values:
- higher than -60dB: : excellent signal quality
- between -60dB and -90dB: good signal quality
- lower than -90dB: poor signal quality that could compromise communication
between device and router. In this case, bring the device closer to the router.
From this screen you can also:
view the status of the Wi-Fi connection: ○
on fixed: device connected to the home network
flashing: Wi-Fi network search in progress or test completed
remove the device from the control of one user (DE-LINK) in order to ○
reconfigure it with another (typical situation, for example, when the device
is installed in a rented property and the tenants change). To carry out the
De-Link, press and hold the key
and until the display shows “”.dEL
The De-Link procedure is finished; at this point the icon on the
humidistat display starts flashing.
• the MAC address of the device
Is a sequence alphanumeric that uniquely identifies a device within a
network of devices. Reading must be done from left to right by scrolling
through the 2 dedicated pages using the arrows
(in the example: AA-F8-FA-C2-8d-7b)
Password for key lock
In particular installation conditions, for example in public buildings, hotels, etc.,
it may be necessary to lock the keypad in order to prevent unauthorized
persons from changing the settings.To enable keypad locking, set a password
between 001 and 999.
In this case set:
• to prevent any changes (keyboard lock)ALL
• to prevent access to advanced programmingPAr
To deactivate the lock, press and hold the key
until “--” is set. When the keypad lock is active,
the symbol
appears on the display and after pressing a key the word appears.BL0C
(To find out how to unlock the keypad, see BOX 9)
Hour meter of system operation
Displays the hours of operation of the system (relay contacts on C-NA).
The unit has two independent (5-digit) meters for dehumidification and
humidification, but only the meter for the selected mode is displayed.
To reset the meter, press and hold the key
long time during the display. The maximum count is
65535h (about 7 years); when this number is reached, the meter resumes counting from 0h.
Minimum/Maximum settable temperature
In certain installation conditions, e.g. public buildings, hotels, etc., it may be
useful to limit the range of values that the temperature can take, in order to
prevent incorrect settings by the user.
• is the lower limitL0
Allowed values: 2°C ÷ Factory value: 2°Cki
• is the upper limit ki
Allowed values: ÷ 50°C Factory value: 50°CL0
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general waste
at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2
, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its
subsequent recycling, helps avoid the potential negative effects on the environment and people’s health,
and encourages the re-use and/or recycling of the construction materials.
REFERENCE STANDARDS
11-2025
EU Declaration of Conformity:
Vemer declares that the device complies with EU Directive 2014/53/EU (RED) with reference to
the following standards: • EN IEC 60730-2-7 • EN IEC 60730-2-9 • ETSI EN 300 328
• ETSI EN 301 489-1 • ETSI EN 301 489-17
The full text of the EU Declaration of Conformity is available at the address www.vemer.it
E-mail
Password
Login
Did you forgot the password?
REGISTER NOW
OR LOGIN WITH:
3s
3s
3s

Beoordeel deze handleiding


Product specificaties

Merk: Vemer
Categorie: Thermostaat
Model: TUO GO WI-FI

Heb je hulp nodig?

Als je hulp nodig hebt met Vemer TUO GO WI-FI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden