Bekijk gratis de handleiding van Hoffman A42SA3210LPPL (2 pagina’s), behorend tot de categorie Stopcontact. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.8 sterren uit 1.5 reviews. Heb je een vraag over Hoffman A42SA3210LPPL of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

Enclosure Alterations
Hoffman Enclosures Inc.
2100 Hoffman Way
Anoka, MN 55303−1745
(763) 422 2211−
www.hoffmanonline.com
Hoffman cannot assure the safety or effectiveness of any alterations or
additions not made by Hoffman Enclosures Inc. However, the following
information may be helpful. These instructions do not eliminate the need
to consult with equipment manufacturers and to observe all regulatory agency procedures and safe
practices to assure the proper electrical and mechanical function of Hoffman products in each
particular application.
1. REPAINTING
See “Instructions for Repainting Hoffman
Standard Paint Finishes”, part number
23155002.
2. MOUNTING INSTRUCTIONS
a. Wall mounted enclosures have either an
internal mounting means or external
mounting feet. Proper fasteners must be
used in all mounting holes to secure the
enclosure to the wall.
b. Floor mounted enclosures have floor
stands (legs) which include mounting
plates. Proper fasteners must be used in
all mounting holes to securely anchor the
enclosure to the floor.
3. DOOR CLOSING ADJUSTMENTS
a. Single door (wall mounted)
If the surface on which the enclosure is
mounted is not flat, the door may not open
and close properly. Also, if heavy
equipment is mounted on a large door, the
door may sag slightly. If the top of the door
strikes the lip which extends around the
body opening, place metal shims behind
the mounting foot which is located at the
bottom of the enclosure and closest to the
door hinge. Place the shims between the
mounting foot and the wall or mounting
surface. Be sure all mounting screws are
tightened securely.
b. Two door (floor mounted)
The overlapping doors are factory fitted to−
meet evenly at the top and bottom. If the
floor under the enclosure is not level, the
doors will not close evenly. In this case,
place metal shims under the corners of the
enclosure. The enclosure should be
bolted in place with the doors closed to
prevent tipping when installing shims.
Shims under the right front corner will raise
the right door. Shims under the left front
corner will raise the left door. It is
important that the doors meet evenly to
insure a proper seal against liquids and
dust. Be sure all mounting bolts are
tightened securely.
4. PANEL INSTALLATION
When the interior panel is being installed, it
may be necessary to bend one or more
mounting studs slightly to permit the panel to fit
in place. Simply position the panel on the studs
that line up properly and pry the other studs
into position with a suitable screwdriver
inserted through the panel holes.
5. REMOVING HINGE PINS FROM
CONTINUOUS HINGES
This can be a difficult operation requiring one or
more people. This procedure is best
accomplished by using a small diameter punch
to drive the hinge pin toward the bottom of the
enclosure. Lay the wall mounted and−
floor mounted or free standing enclosure on− −
its back side (see note 7 below). When the
hinge pin protrudes about two inches below the
bottom hinge barrel, bend the end of the pin
180° so it is shaped like the letter “J”. Use an
electric or air powered vibrating hammer fitted
with a tool which has a hole in the end to fit
over the hinge pin, and drive the hinge pin out
while opening and closing the door. To install
the hinge pin, straighten the pin and drive it in
with the vibrating hammer while opening and
closing the door. Most hinge pins have one
end chamfered, so be sure to start the
chamfered end first when installing the pin.
6. PRINT POCKET
The print pocket on the door can be inverted or
removed entirely.
7. LIFTING ENCLOSURES BY EYEBOLTS
To lift an enclosure which has eyebolts or
mounting feet, be sure to use all the eyebolts
and top mounting feet provided. Arrange the
chains and cables with spreader bars so you
are lifting straight up on the eyebolts or top
mounting feet.
87569073
Rev. B 110539 P/N 99401677E 2004 Hoffman Enclosures Inc.
®

− − 2 87569073
E 2004 Hoffman Enclosures Inc.
ACCESSORIES AND HARDWARE
Hoffman cannot assure the safety or
effectiveness of any alterations or additions
not made by Hoffman Enclosures Inc.
Lock kits
and latch kits are available for field
or factory installation on many types of
Hoffman enclosures. Lock kits provide
key locking capabilities. Latch kits permit−
rapid access to enclosure interiors while
retaining the oil tight and dust tight features.
Louver plate kits
provide ventilation in
enclosures where internal heat is a problem.
Floor stand kits for converting wall mounting
enclosures to floor mounting are available for
field or factory installation on single door
NEMA 12 and NEMA 4 enclosures.
Drip shield kits are available for field or
factory installation on single door and double
door NEMA 12 enclosures.
Electrical interlocks provide a positive
internal safety lockout on electrical
enclosures while the enclosure contents are
energized.
Swing out panel kits− provide a means of
mounting gauges, switches, pilot lights and
other components near the front of the
enclosure.
Safety Lockouts protect personnel and
equipment by enabling multiple padlocks to
be installed on a de energized switch.−
Touch up paint−
is used to repair the finish of
enclosures and panels.
Window kits
are available for many types of
Hoffman enclosures.
Corrosion inhibitors protect interior
components of enclosures, wireway,
consoles, etc. from corrosion. There are no
coatings, oils, or greases to apply.
Hole seals are used to seal extra conduit
openings, pushbutton holes, cutouts, etc.
against dust, dirt, oil, and water.
Terminal kit assemblies provide an easy
method to mount terminal blocks in many
types of Hoffman enclosures.
Folding Shelves can be used to support
instruments and test equipment.
Pedestals are used to provide floor mounting
at a working height for small to medium size
enclosures.
OTHER HOFFMAN PRODUCTS
S NEMA 1, NEMA 3R, NEMA 4, NEMA 4X,
NEMA 9, and NEMA 12 enclosures
S Oil tight JIC boxes and troughs.
S Oil tight wireway and lay−in wireway
S NEMA 1 wireway
S Oil tight pushbutton enclosures
S Cutout boxes, pull boxes, and transformer
cabinets
S Non−metallic enclosures
S Stainless steel enclosures and boxes
S Aluminum enclosures and boxes
S Console cabinets
S Custom−built enclosures of all types
S Instrument and electronic enclosures
S Environmental control products
S EMI/RFI shielded enclosures
S Wiring duct
S Modified Standard Enclosures
S Co−Developed Enclosures
Product specificaties
Merk: | Hoffman |
Categorie: | Stopcontact |
Model: | A42SA3210LPPL |
Kleur van het product: | Grijs |
Breedte: | 797 mm |
Diepte: | 254 mm |
Hoogte: | 1067 mm |
Internationale veiligheidscode (IP): | IP65 |
Certificering: | UL 508A Listed; Type 12, 13; File No. E61997\ncUL Listed per CSA C22.2 No. 94; Type 12, 13; File No. E61997 \nNEMA/EEMAC Type 12, 13\nCSA File No. 42186: Type 12 \nIEC 60529 |
Materiaal: | Staal |
Heb je hulp nodig?
Als je hulp nodig hebt met Hoffman A42SA3210LPPL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stopcontact Hoffman
4 April 2025
4 April 2025
4 April 2025
4 April 2025
4 April 2025
4 April 2025
4 April 2025
4 April 2025
Handleiding Stopcontact
- AV:link
- Anslut
- PS Audio
- Gamma
- Kopp
- Bose
- Lanberg
- Digitus
- Pancontrol
- PureLink
- Crestron
- V-Tac
- Heitronic
- Extron
- Eurolite
Nieuwste handleidingen voor Stopcontact
16 Juni 2025
11 Juni 2025
11 Juni 2025
10 Juni 2025
10 Juni 2025
15 Mei 2025
15 Mei 2025
13 Mei 2025
13 Mei 2025