CyberPower PR2200LCD Handleiding

CyberPower UPS PR2200LCD

Lees hieronder de 📖 handleiding in het Nederlandse voor CyberPower PR2200LCD (2 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
PR22 3000LCD / PR 00LCD
User Manual s
K01- 252-01 0000
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
contaminants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before
servicing the batteries. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer
component.
CAUTION! To reduce the risk of fire, connect onl y to a circuit provided with 30 amperes maximum branch circuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or DO NOT
patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation
such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
INTRODUCTION
Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and
performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS unit (b) Users manual (c) Emergency Power Off cable (gray) (d PowerPanel) ® Business Edition software CD (e Serial cable (f USB ) )
A+B type cable (g Warranty registration card (h Function Setup Guide ) )
OVERVIEW
The PR 00LCD/PR 00LCD UPS provides complete power protection from utility power that isn't always consistent. The 22 30
PR2200LCD/PR3000LCD features surge protection against power surges and maintenance free batteries for long lasting battery backup during
power outages. In addition to ensuring consistent power to your computer system and the
PR2200LCD/PR3000LCD also includes software that will automatically save your open files
and shutdown your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
T 0LCD/PR3000LCD stabilizes inconsistent utility power voltage to nominal levels that he PR220
are safe for equipment. Inconsistent utility power may be damaging to important data files and hardware ,
but with Automatic Voltage Regulation (AVR), damaging voltage levels are corrected to safe levels. AVR
automatically increases low utility power and decreases high utility power to a consistent and safe
110/120 volts.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into the outlets y ( 00 0W for LCDdoes not exceed the UPS unit’s rated capacit 22 VA/198 PR2200 ,
30 2700 3000VA/ W for PR 00LCD). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit
to shut down or the circuit breaker to trip.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, to ensure the battery’s maxi mum
charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is
equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will
automatically charge whether the UPS is turned on or off.
2. Note: This UPS is designed with a safety feature to keep the system from being turned on during
shipment.
The first time you turn the UPS , you will need to have it connected to AC power or it will not power up.on
3. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the
battery power supplied outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large
electrical devices into the Battery and Surge Protected Outlets may overload and damage ”. The power demands of these devices
the unit.
4. ed Plug the UPS into a 2 pole, 3 wire ground receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit
breaker and does not service equipment with large electrical demands (e.g. air conditioner, The warranty prohibits the use of copier, etc…).
extension cords, outlet strips, and surge strips.
5. Press the power switch to turn the unit on. The Power On indicator light will illumin . ate and the unit will “beep”
If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three
months to ensure battery life.
8. Insure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
9. The LCD module is wall-mountable for extended distance control. Follow the steps below for installation procedure.
a. Remove the LCD module from the front panel.
b. Hang the LCD module on the wall.
c. Replacing the LCD on the UPS - To place the LCD back on the UPS, roll up the LCD cable, return it to the space between the front panel &
battery cover, and replace the LCD.
DESCRIPTION
Front Panel
1 Power Switch / Power On Indicator
Used as the master on/off switch for equipment connected to the battery power supplied outlets.
2 Online Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3 On Battery Indicator
During a severe brownout or blackout, this LED is illuminated and an alarm sounds (two short beeps followed by a pause) to indicate the
UPS is operating f m its internal batteries. ro
4 Fault
This LED is illuminated if there is a problem with the UPS.
5 Replace Battery Indicator
This LED is illuminated to remind users to replace the battery.
6 Status/Tab Button
For UPS status information, press the button for 1 second. For additional information including
the use of the button as a Tab, please refer to the . Function Setup Guide
7 Setup/Enter Button
Press the Setup button for 1 second to enter setup menu and then select the functions for
configuration. For more information about the Setup/Enter button, please refer to the Function
Setup Guide.
8 Control/Up Button
Press the Control button for 1 second to enter control menu and then select the functions for
configuration. This button is also used to scroll up. For more information about the Control/Up
button, please refer to the . Function Setup Guide
9 Test/Down Button
Press the Test switch for 1 second to enter test menu and then select the functions for
configuration. This button is also used to scroll down. For more information about the Test/Down
button, please refer to the . Function Setup Guide
10 Logs/Esc Button
Press the Logs button for 1 second to view the events or logs that have been recorded.
This button is also used to exit a menu. For more information about Logs/Esc button ,
please refer to the . Function Setup Guide
Rear Panel
1 Battery and Surge Protected Outlets
The unit has ten battery powered and surge protected outlets for connected equipment to
ensure temporary uninterrupted operation of your equipment during a power failure.
(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump
pump or other large electrical devices into the Battery and Surge Protected Outlets “ ”.
The power demands of these devices may overload and damage the unit.)
2 Serial/USB Ports to PC
The Serial and USB ports allow connection and communication between the
computer and the UPS unit. Note: Only one port can be used at a time.
3 EPO Port
Use the provided gray EPO cable to connect to a provided contact switch. EPO
Follow the appropriate circuit diagram to the right to wire the cable to your
EPO configuration. The EPO remote switch is a switch installed in an outside
area, connected to the unit via the Emergency Power Off cable. In case of an
emergency, it can be used to immediatel y cut-off power from the UPS.
4 TVSS Ground
The TVSS GND only used for dielectric voltage-withstand test on production.
5 SNMP/HTTP Network Slot
Remove the cover panel to install an optional RMCARD to remotely monitor
and manage your UPS over a network.
6 Input Circuit Breaker
Located on the back of the UPS, the circuit breaker provides overload and
fault protection.
7 Output Circuit Breaker
Located on the back of the UPS, the circuit breaker provides overload and fault protection.
8 AC Input Power Cord
Heavy-duty power cord.
REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA.
1. 0X 22 When replacing batteries, replace with the same number of the following battery: CyberPower / RB1217 4 for the PR 00LCD and
PR3000LCD. Contact CyberPower Systems about replacement batteries.
2. Risk of Energy Hazard, V, maximum Ampere-hour battery. Before replacing batteries, remove conductive jewelry such CAUTION! 12 20
as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns.
3. Do not dispose of batteries in a fire. The batteries may explode. CAUTION!
4. Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. CAUTION!
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING
TO LOCAL REGULATIONS.
BATTERY REPLACEMENT PROCEDURE:
1. Turn off and unplug all connected equipment.
2. Turn the UPS off and unplug it from the AC power source.
3. Remove the front panel of the UPS.
4. Remove two screws from the battery compartment cover and slide the cover completely off of the unit.
5. out Pull the battery pack on the outside from the compartment. Disconnect the battery connector from the batteries.
6. Before removing the battery pack on the inside, unlock the cable tie and pull out the battery wires. Disconnect the battery connector from
the batteries. Pull out the battery pack on the inside from the compartment.
7. Install the replacement battery pack on the inside by connecting the wire bundle connector (composed of one red wire and one black wire)
to the connector from the battery pack. Lock the battery wires back with the cable tie.
8. Install the replacement batteries on the outside by connecting the wire bundle connector (composed of one red wire and one black wire) to
the connector from the battery pack. Put the battery pack on the outside back into the compartment.
9. -install the battery compartment cover and tighten the retaining screws. Re
10. Put the front panel back on the UPS.
11. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.
Note: The battery pack on the outside a fuse, while the battery pack on the inside has not. has
REMINDER: Batteries are consider ed HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries
collect used batteries for recycling, as required by local regulations.
Status Menu/Switch
Operation Mode
Load Power
Load VA
Load Amps
Load Energy
Estimated Runtime
Battery Information
Input
t Ou put
Last Self Test
Date & Time
NCL Output
Setup Menu/Switch
Setup Wizard
Utility Power
MIN O/P Voltage
MAX O/P Voltage
LCD Auto Sleep
Cycling Display
Audible Alarm
Temporarily Mute
Sensitivity
Date & Time
Battery Change Date
Firmware Update
Power Meter Reset
Back to Default
Delay Turn On
Delay Turn Off
Reboot Duration
Minimum Restore Capacity
BASIC OPERATION
INSTALLING YOUR UPS SYSTEM
IMPORTANT SAFETY WARNINGS
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
Charge Mode
Low Battery Warning
Auto Self Test
Uptime on Battery
Reserve Runtime
Configure NCL
Control Menu/Switch
UPS On /Off
NCL On/Off
Test Menu/Switch
Self Test
Alarm Test
Battery Calibration
Logs Menu/Switch
Transfer Event X1-X 10
Fault Event F1-F 10
Model Name
Last Battery Change
Next Battery Change
UPS Firmware Version
LCD Firmware Version
Serial Number
For more information about functions setup, please refer to the .Function Setup Guide
Possible Cause
Solution
Circuit breaker has tripped due to
an overload.
Turn the UPS off and unplug at least one piece of equipment.
Wait 10 seconds, reset the circuit breaker by pressing the
button , and then turn the UPS on.in
Battery not fully charged.
Recharge the battery by leaving the UPS plugged in.
Battery is worn out.
Contact CyberPower Systems about replacement batteries.
The on/off switch is designed to
prevent damage from rapidly
turning it off and on.
Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit is not connected to an AC
outlet.
The unit must be connected to a 110/120V 60Hz outlet.
The battery is worn out.
Please contact CyberPower Systems about replacement
batteries.
Mechanical problem.
Please contact CyberPower Systems.
The USB / serial cable is not
connected.
Connect the USB / serial cable to the UPS unit and an open
USB / serial port on the back of the computer. You must use
the cable that came with the unit.
The USB / serial cable is connected
to the wrong port.
Check the back of the computer for an additional USB / serial
port. Move the cable to this port.
The unit is not providing battery
power.
Shutdown your computer and turn the UPS off. Wait 10
seconds and turn the UPS back on. This should reset the unit.
The serial cable is not the cable that
came with the unit.
Please use the serial cable that came with the unit for the
software.
Overload
Remove excessive load and restart the UPS.
Output Short
Please contact CyberPower Systems.
Battery Overcharge
Please contact CyberPower Systems.
Over Temperature
Please contact CyberPower Systems.
Additional troubleshooting information can be found under Support at www.cyberpower.com
Model
PR2200LCD
PR3000LCD
Capacity
2200VA / 1980W
30 270000VA / W
Nominal Input Voltage
12 0Vac
Input Frequency
50/60Hz
On-Battery Output Voltage
120Vac ± 5%
On-Battery Output Wave Form
Sine Wave
Operating Temperature
+ 32°F to 104° F / 0° C to ° C 40
Operating Relative Humidity
0 to 95 -condensing % non
Size (L x W x H)
20.2" x 7.7" x " (513 x 1 2mm) 17 96 x 43
Net Weight
116 lbs
124 lbs
Battery Type
CyberPower RB12170X4 /
Typical Battery Recharge Time
8 hours from total discharge
Typical Battery Life
3 to 6 years, depending on number of discharge/recharge cycles
Recommended Battery
Sealed Maintenance Free Lead Acid Battery
Safety Approvals
UL1778 CSA C22.2 No 107.3, FCC/DoC Class A ,
SYSTEM FUNCTIONAL BLOCK DIAGRAM
Advanced Energy-Saving Patented Bypass Technology
CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to
75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models
constantly pass power through a transformer. By contrast, under normal conditions the advanced circuitry
of a GreenPower UPS™ bypasses the transformer. As a result, the power efficiency is significantly
increased while decreasing waste heat, using less energy, and reducing energy costs.
When an abnormal power condition occurs, the GreenPower UPS™ automatically runs power through its
transformer to regulate voltage and provide “safe” power. Since utility power is normal over 88% of the time, the GreenPower UPS™
operates primarily in its efficient bypass mode.
The GreenPower UPS™ is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making
it one of the most environmentally-friendly on the market today.
Read the following terms and conditions carefully before using the CyberPower 0 (PR22 0LCD 3000LCD/PR the “Product”). By using
the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Connected
Equipment Guarantee (together referred to as this “Warranty”). If you do not agree to the terms and conditions of this Warranty, you
should return the Product for a full refund prior to using it.
Who is Providing this Warranty?
CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty.
What Does This Warranty Cover?
This warranty covers defects in materials and workmanship in the Product under normal use and conditions. It also covers
equipment that was connected to the Product and damaged because of the failure of the Product.
What is the Period of Coverage?
This warranty covers the Product for three years and connected equipment for as long as you own the Product.
Who Is Covered?
This warranty only covers the original purchaser. Coverage ends if you sell or otherwise transfer the Product.
How Do You Get Warranty Service?
1. Before contacting CyberPower, identify Your Product model number, the Purchase Date, and each item of Connected
Equipment (E.G. Computer tower, Computer Monitor, Ink Jet Printer, Cable Modem, etc).
2. Visit our web site at http://www.cpsww.com/support or Call us at (877) 297- . 6937
3. . If your product requires warranty service you must provide a copy of your dated purchase receipt or invoice
How Do You Open A Connected Equipment Claim?
1. Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 4241 12th Ave. E., Suite 400, Shakopee, MN
55379, or send us an e-mail message at claims@cpsww.com for instructions, within 10 days of the occurrence.
2. When you contact CyberPower, identify the Product, the Purchase Date, and the item(s) of Connected Equipment. Have
information on all applicable insurance or other resources of recovery/payment that are available to the Initial Customer and
Request a Claim Number.
3. You must provide a dated purchase receipt (or other proof of the original purchase) and provide a description of the damage to
your connected equipment.
4. Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the
damage to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the Claim Number on the
shipping label or include it with the product. You must prepay all shipping costs, you are responsible for packaging and
shipment, and you must pay the cost of the repair estimate.
How Long Do I Have To Make A Claim?
All claims must be made within ten days of the occurrence.
What Will We Do To Correct Problems?
CyberPower will inspect and examine the Product.
If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if
CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund
to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).
If it appears that our Product failed to protect any equipment plugged into it, p2-we will also send you forms for making your claim for the
connected equipment. We will repair or replace the equipment that was damaged because of the failure of our Product or pay you
the fair market value (NOT REPLACEMENT COST) of the equipment at of the time of the damage. We will use Orion Blue Book, or
another a third-party valuation guide, or eBay, craigslist, or other source to establish that amount. Our maximum liability is limited to
$ 5 2200LCD and PR 00LCD. 37 ,000 for the PR 30
Who Pays For Shipping?
We pay when p2-we send items to you; you pay when you send items to us.
What isnt covered by the warranty?
1. This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any
data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of software.
2. This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental limits of the Product
or the equipment connected to it, nor for damage while in transit or in storage, nor if there has been improper operation or
maintenance, or use with items not designed or intended for use with the Product, such as laser printers, appliances, aquariums,
medical or life support devices, etc.
What are the Limitations?
The sole and exclusive remedies of the Initial Customer are those provided by this Warranty.
1. This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired
and grounded outlets (including compliance with electrical and safety codes of the most current electrical code), without the use
of any adapters or other connectors.
2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be
directly connected to the Product and not “daisy chained” together in serial fashion with any extension cords, another Product -
or device similar to the Product, surge suppressor, or power tap. Any such installation voids the Limited Warranty.
3. The Product and equipment connected to it must have been used properly in a suitable and proper environment and in
conformance with any license, instr tion manual, or warnings provided with the Product and the equipment connected to it. uc
4. The Product must have been used at all times within the limitations on the Product’s VA capacity.
The Product was designed to eliminate disrupting and damaging effects of momentary (less than 1ms) voltage spikes or impulses
from lightning or other power transients. If it can be shown that a voltage spike lasting longer than 1ms has occurred, the occurrence
will be deemed outside the rated capabilities of the Product and the Limited Warranty is void. CyberPower Does Not Cover or
Undertake Any Liability in Any Event for Any of the Following:
1. Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of software.
2. Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded and
code-compliant 120 volt power lines in the United States and Canada; transients, surges or spikes on standard telephone land
lines, PBX telephone equipment lines or Base 10T Ethernet lines, when properly installed and connected. (This exclusion
applies, for example, to fluctuations in data transmission or reception, by CATV or RF transmission or fluctuations, or by
transients in such transmission.)
3. any circumstance described as excluded above with respect to the Product. Damage from
4. e Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or alteration of either th
product or the Connected Equipment.
5. any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee. CyberPower excludes
CyberPower excludes any liability for direct, indirect, special, incidental or consequential damages, whether for damage to or
loss of property [EXCEPT FOR (AND ONLY FOR) the specific limited agreement of CyberPower to provide certain warranty
benefits regarding "Connected Equipment" under this Warranty], loss of profits, business interruption, or loss of information or
data. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation may not apply to you.
6. The Product is not for use in high-risk activities or with aquariums. The Product is not designed or intended for use in hazardous
environments requiring fail-safe performance, or for use in any circumstance in which the failure of the Product could lead
directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical
or life support device (collectively, "High Risk Activities"). CyberPower expressly disclaims any express or implied warranty of
fitness for High Risk Activities or with aquariums. CyberPower does not authorize use of any Product in any High Risk Activities
or with Aquariums. . ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded.
CyberPower is the warrantor under this Limited Warranty.
For further information please feel free to contact CyberPower at CyberPower Systems (USA), Inc. 4241 12
th Ave E., Suite 400,
Shakopee, MN 55379; call us at (877) 297- -mail message at . 6937; or send us an e claims@cpsww.com
CyberPower Systems encourages environmentally sound methods for disposal and recycling of its UPS products.
Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state.
All rights reserved Reproduction without permission is prohibited. .
TECHNICAL SPECIFICATIONS
Limited Warranty and Connected Equipment Guarantee
CYBERPOWER GREENPOWER UPS TECHNOLOGY
EMI
Filter
Surge
Suppressor
AVR
Charger
AC/DC
Battery
Inverter
Input
Output
Normal Mode
Battery Mode
TROUBLESHOOTING


Product specificaties

Merk: CyberPower
Categorie: UPS
Model: PR2200LCD
Kleur van het product: Zwart
LED-indicatoren: Ja
Vormfactor: Tower
Certificering: UL1778, cUL CSA C22.2 No. 107.3, FCC DOC B
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: ENERGY STAR
Uitgangsvermogen: 1980 W
Frequentie: 47/63 Hz
Stekker: NEMA L5-30P
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 90 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Type beeldscherm: LCD
Type batterij: RB12170
Surge energy rating: 1030 J
Aantal AC uitgangen: 10 AC-uitgang(en)
Stopcontacttypes: NEMA 5–15R,NEMA 5–20R
Output power capacity: 2.2 kVA
Ingang operation voltage (min): 75 V
Ingang operation voltage (max): 154 V
Uitgang operation voltage (min): 120 V
Uitgang operation voltage (max): 120 V
UPS-topologie: Line-interactive
Typische backup tijd op halve lading: 26 min
Typische backup tijd op volledige lading: 8 min
Hot-swap batterij: Ja
EMI/RFI geluidsfiltering: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower PR2200LCD stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS CyberPower

Handleiding UPS

Nieuwste handleidingen voor UPS