CyberPower OL8000E Handleiding

CyberPower UPS OL8000E

Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor CyberPower OL8000E (21 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/21
Userโ€™s Manual
OL6000ERT3UD๎€ƒ
OL8000ERT3UD๎€ƒ
OL10000ERT3UD๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
CyberPower Systems Inc.
www.cpsww.com๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
๎€ƒ
K01โ€0000220โ€00๎€ƒ
๎€ƒ
Copyright ยฉ 2011 CyberPower Systems, Inc.๎€ƒ
IMPORTANT SAFETY INSTRUCTIONS
1๎€ƒ
๎€ƒ
๎€ƒ
This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual
thoroughly before attempting to unpack, install, or operate the UPS.
๎€ƒ
CAUTION! The UPS must be connected to a grounded AC power
outlet with fuse or circuit breaker protection. DO NOT plug the UPS into
an outlet that is not grounded. If you need to power-drain this equipment,
turn off and unplug the unit.
CAUTION! The battery can power hazardous components inside the
unit, even when the AC input power is disconnected.
CAUTION! The UPS should be placed near the connected equipment
and easily accessible.
CAUTION! To prevent the risk of fire or electric shock, install in a
temperature and humidity controlled indoor area, free of conductive
contaminants. (Please see specifications for acceptable temperature and
humidity range).
CAUTION! (No User Serviceable Parts): Risk of electric shock, do
not remove cover. No user serviceable parts inside. Refer servicing to
qualified service personnel.
CAUTION! (Non-Isolated Battery Supply): Risk of electric shock,
battery circuit is not isolated from AC power source; hazardous voltage
may exist between battery terminals and ground. Test before touching.
CAUTION! To reduce the risk of fire, connect the UPS to a branch
circuit with 40 amperes (OL6000) / 50 amperes (OL8000) / 60 amperes
(OL10000) maximum over-current protection in accordance to CE
requirement.
CAUTION! The AC outlet where the UPS is connected should be close
to the unit and easily accessible.
CAUTION! Please use only VDE-tested, CE-marked mains cable, (e.g.
the mains cable of your equipment), to connect the UPS to the AC outlet.
CAUTION! Please use only VDE-tested, CE-marked power cables to
connect any equipment to the UPS.
CAUTION! When installing the equipment, ensure that the sum of the
leakage current of the UPS and the connected equipment does not
exceed 3.5mA.
CAUTION! The OL6000 / OL8000 / OL10000 models are
permanently-connected equipment and only qualified maintenance
personnel may carry out installations.
CAUTION! Do not unplug the unit from AC Power during operation, as
this will invalidate the protective ground insulation.
CAUTION! To avoid electric shock, turn off and unplug the unit before
installing the input/output power cord with a ground wire. Connect the
ground wire prior to connecting the line wires!
CAUTION! Do not use an improper size power cord as it may cause
damage to your equipment and cause fire hazards.
CAUTION! Wiring must be done by qualified personnel.
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT
EQUIPMENT! Under no circumstances this unit should be used for
medical applications involving life support equipment and/or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce
the risk of fire, do not use with or near aquariums. Condensation from
the aquarium can come in contact with metal electrical contacts and
cause the machine to short out.
CAUTION! Do not dispose of batteries in fire as the battery may
explode.
CAUTION! Do not open or mutilate the battery, released electrolyte is
harmful to the skin and eyes.
CAUTION! A battery can present a risk of electric shock and high short
circuit current. The following precaution should be observed when
working on batteries
1. Remove watches, rings or other metal objects.
2. Use tools with insulated handles.
CAUTION! The unit has a dangerous amount of voltage. When the
UPS indicators is on, the units may continue to supply power thus the
unitโ€™s outlets may have a dangerous amount of voltage even when itโ€™s not
plugged in to the wall outlet.
CAUTION! Make sure everything is turned off and disconnected
completely before conducting any maintenance, repairs or shipment.
CAUTION! Connect the Protection Earth (PE) safety conductor before
any other cables are connected.
WARNING! (Fuses): To reduce the risk of fire, replace only with the
same type and rating of fuse.
DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO
DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE!
DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE
HOUSING!
DO NOT CONNECT DOMESTIC APPLIANCES SUCH AS HAIR
DRYERS TO UPS OUTPUT SOCKETS!
SERVICING OF BATTERIES SHOULD BE PERFORMED OR
SUPERVISED BY PERSONNEL KNOWLEDGE OF BATTERIES AND
THE REQUIRED PRECAUTIONS. KEEP UNAUTHORIZED
PERSONNEL AWAY FROM BATTERIES!
๎€ƒ
๎€ƒ
Copyright ยฉ 2011 CyberPower Systems, Inc.๎€ƒ
UNPACKING
๎€ƒ
Power module
Input / Output terminal block cover
2๎€ƒ
Userโ€™s manual Register card
Rackmount left rail * 2 sets Rackmount right rail * 2 sets
Phone line
USB communication cable
Serial Interface Cable (RS-232)
Battery module
Rackmount ears (Stands) (2) * 2 sets
Tie plate (1) * 2 sets
Flat head screws: M5X8L (8) * 2 sets
Pan head screws: M5X12L (12) * 2 sets
Plastic washers (8) * 2 sets
Screw hole dust covers (10) * 2 sets
Power cords
PowerPanelยฎ Business Edition software CD
๎€ƒ ๎€ƒ


Product specificaties

Merk: CyberPower
Categorie: UPS
Model: OL8000E
Kleur van het product: Zwart
Gewicht: 97000 g
Breedte: 265 mm
Diepte: 660 mm
Hoogte: 616 mm
LED-indicatoren: Batterijvervanging
Vormfactor: Tower
Ingebouwde ventilator: Ja
Accu/Batterij voltage: 12 V
Aantal USB 2.0-poorten: 1
Aantal Ethernet LAN (RJ-45)-poorten: 1
Ondersteund aantal accu's/batterijen: 20
RS-232 port: 1
Geluidsalarm(en): Ja
Meegeleverde software: PowerPanel BE
Uitgangsvermogen: 7200 W
Batterij capaciteit: 9 Ah
Accu/Batterij oplaadtijd: 5 uur
Stroomspanning bescherming: Kortsluiting
Frequentie: 40/70 Hz
Type koeling: Actief
Seriรซle poort(en): 1
Modem (RJ-11) poort: 1
Stekker: Eindstation
Auto-herstart: Ja
Efficientie: 95 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Type beeldscherm: LCD
Aantal AC uitgangen: 10 AC-uitgang(en)
Stopcontacttypes: C13 coupler,C19 coupler,Terminal
Golf protectie functies: Fax,Modem,Network,Telephone
Output power capacity: 8 kVA
Ingang operation voltage (min): 120 V
Ingang operation voltage (max): 280 V
Uitgang operation voltage (min): 200 V
Uitgang operation voltage (max): 240 V
Typische backup tijd op halve lading: 13.5 min
Typische backup tijd op volledige lading: 5.5 min
Hot-swap batterij: Ja
Hoorbare alarmstanden: Batterijvervanging
Emergency Power Off (EPO): Ja
EMI/RFI geluidsfiltering: Ja
Spanningsbeveiliging: Ja
Golfvorm: Sinus
Koude start: Ja
Uitgangsfrequentieregeling: 50/60 Hz
Automatische batterij test: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower OL8000E stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS CyberPower

Handleiding UPS

Nieuwste handleidingen voor UPS