Tripp Lite Internet600 Handleiding

Tripp Lite UPS Internet600

Lees hieronder de đź“– handleiding in het Nederlandse voor Tripp Lite Internet600 (16 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Owner’s Manual
WARRANTY
REGISTRATION:
register online today for a chance
to win a FREE Tripp Lite product—
www.tripplite.com/warranty
Internet Office®& BC Personal®
UPS Systems
120V AC Input
Not suitable for mobile applications
Safety
Quick Installation
Storage and Service
Warranty Registration
Basic Operation
Español
1111 W. 35th Street • Chicago, IL 60609 USA
(773) 869-1234 • www.tripplite.com
Copyright © 2007 Tripp Lite. All rights reserved. Internet Office ®and BC Personal®are registered trademarks of Tripp Lite.
Français
2
2
3
4
5
6
12
Optional Installation 3
200611001 93-2641 350U OM.qxd 1/4/2007 2:16 PM Page 1
2
Important Safety Instructions
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct
sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself;
this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground
connection.
• Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything
other than Tripp Lite surge suppressors are used to connect your UPS to an outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean,
filtered, computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of
a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device.
• Do not connect surge suppressors or extension cords to the output of your UPS. This might damage the
UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason. There are no user-
serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper
precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or
bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery
replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the same number and type of
batteries (sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal
requirements or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-822-8837) or visit
www.rbrc.com for recycling information. Tripp Lite offers a complete line of UPS System Replacement
Battery Cartridges (R.B.C.).Visit Tripp Lite on the web at www.tripplite.com/support/battery/index.cfm to
locate the specific replacement battery for your UPS.
• Do not attempt to add external batteries to the UPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation
and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.
Quick Installation
1. Plug the UPS into an outlet that doesn’t share a circuit with a heavy electrical load.*
* An air conditioner, refrigerator, etc.
2. Turn the UPS on: Press and hold the ON/OFF/TEST button for one second to turn the UPS on. The UPS
alarm will beep once briefly after one second has passed. NOTE: The UPS will not turn on, even if connected
to live utility power, until it is turned on using the ON/OFF/TEST button.
3. Plug your equipment into the UPS: Select outlets (see Basic Operation section) will provide battery backup
and surge protection; connect your computer, monitor and other critical devices here.* Select outlets (see
Basic Operation section) will provide surge protection only; connect your printer and other non-essential
devices here.
* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings for all the equipment
you connect to the Battery Backup Protected/Surge Protected outlets exceeds the UPS’s Output Capacity. To find your equipment’s VA
ratings, look on their nameplates. If the equipment is listed in amps, multiply the number of amps by 120 to determine VA. (Example:
1 amp Ă— 120 = 120 VA). If you are unsure if you have overloaded the Battery Backup Protected/Surge Protected outlets, run a self-
test (see “ON/OFF/TEST” Button description).
200611001 93-2641 350U OM.qxd 1/4/2007 2:16 PM Page 2
3
Optional Installation (Select Models Only)
Select models feature Tel/DSL surge suppression and USB or DB9 communication capabilities. These
connections are optional. The UPS System will function properly without these connections.
Tel/DSL Line Surge Suppression: Select UPS models can protect equipment against surges over a single phone
line. Using telephone cords, connect your wall jack to the UPS jack marked with a “ ” symbol. Connect your
equipment to the UPS jack marked with a “ ” symbol. Make sure the equipment you connect to the UPS's jacks
is also protected against surges on the AC line.
USB or DB9 Communications: Select UPS models feature a communication port that can be connected to any
computer, enabling PowerAlert Software to automatically save open files and perform unattended shutdown in
the event of a power failure. Connect one end of the included communication cable to the communication port
on the side of your UPS System. Connect the other end of the included cable (featuring either a USB or DB9
connector, depending on model) to the communication port on your computer. If PowerAlert Software is
included with your UPS, insert the CD into the CD tray of your computer and follow the installation instructions.
If PowerAlert Software is not included, you can download the software FREE from Tripp Lite's website at
www.tripplite.com.
Basic Operation
ON/OFF/TEST
Button
ON/OFF LED OVERLOAD/
CHECK
BATTERY LED
Battery Backup/
Surge Protected
Outlets
Tel/DSL Jacks
(Select models
only.)
Resettable Circuit
Breaker
Surge-Only
Protected Outlets
1 2 3 4 5
86 7
“ON/OFF/TEST” Button
•To turn the UPS on: Press and hold the ON/OFF/TEST Button for one second.* If utility power is
absent, pressing the Button will “cold-start” the UPS, i.e. turn it on and supply power from its
batteries.**
•To turn the UPS off: Press and hold the ON/OFF/TEST Button for one second.* The UPS will be turned
completely off (deactivated).
•To run a Self-Test: With your UPS plugged in and turned ON, press and hold the ON/OFF/TEST button
for three seconds.
* The alarm will beep once briefly after one second has passed. **If fully charged.
CAUTION! To perform a self-test, you must hold the ON/OFF/TEST button continuously for three
seconds; if you release the button too early, you will turn the UPS system OFF and cut power to
connected equipment loads. To ensure you hold the button for the correct length of time, do not
release the button until you hear the UPS System's audible alarm beep twice. The first beep occurs
after one second and indicates that the UPS will turn OFF if the button is released. The second beep
occurs after three seconds and indicates that the UPS will perform a self-test if the button is released.
The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and
charge. All LEDs will be lit and the UPS alarm will sound. See LED descriptions below to determine the
results of the Self-Test.
Note: You can leave connected equipment on during a self-test.
CAUTION! Do not unplug your UPS to test its batteries. This will remove safe electrical grounding
and may introduce a damaging surge into your network connections.
“ON/OFF” LED: This green LED lights continuously to indicate that the UPS is ON and supplying your
equipment with AC power either from a utility source or from the UPS’s internal batteries. If the UPS’s
alarm is sounding (4 short beeps followed by a pause), the UPS is operating from its internal batteries.
1
Communication Port
(Select models only. For use with included
USB or DB9 cable.)
2
200611001 93-2641 350U OM.qxd 1/4/2007 2:16 PM Page 3


Product specificaties

Merk: Tripp Lite
Categorie: UPS
Model: Internet600

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite Internet600 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Tripp Lite

Handleiding UPS

Nieuwste handleidingen voor UPS