Bekijk gratis de handleiding van Tripp Lite BC350 (24 pagina’s), behorend tot de categorie UPS. Deze gids werd als nuttig beoordeeld door 52 mensen en kreeg gemiddeld 5.0 sterren uit 26.5 reviews. Heb je een vraag over Tripp Lite BC350 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/24

1
Owner’s Manual
Internet Office® & BC Personal®
UPS Systems
Not suitable for mobile applications.
Important Safety Instructions 2
Quick Installation 3
Basic Operation 4
Storage & Service 7
Español 9
Warranty Registration 7
Français 16
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2010 Tripp Lite. All rights reserved.
Internet Office® and BC Personal
® are registered trademarks of Tripp Lite.
Register
online today
for a chance to win a
FREE Tripp Lite product!
www.tripplite.com/warranty
201004182 93-2292.indb 1 5/6/2010 11:30:36 AM

2
Important Safety Instructions
SAVE THESE INSTRUCTIONS—This manual contains instructions and warnings that
should be followed during the installation, operation and storage of all Tripp Lite UPS
Systems. Failure to heed these warnings may affect your warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F (0º C and
40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the
UPS into itself; this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s
ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of your UPS. This
might damage the UPS and may affect the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason.
There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the
UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug
and turn off the UPS before performing battery replacement. Use tools with insulated
handles. There are no user-serviceable parts inside the UPS. Battery replacement should
be performed only by authorized service personnel using the same number and type of
batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for
disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling
information. Tripp Lite offers a complete line of UPS System Replacement Battery
Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/
index.cfm to locate the specific replacement battery for your UPS.
• Do not attempt to add external batteries to the UPS.
201004182 93-2292.indb 2 5/6/2010 11:30:36 AM

3
1 Plug the UPS into a properly grounded AC outlet.
After plugging the UPS into a wall outlet, push the ON/OFF/TEST button for one
second to turn the UPS on (see Basic Operation section). Please Note! will The UPS
not turn on automatically in the presence of live utility power.
2 Plug your equipment into the UPS.
Select outlets (see Basic Operation section) will provide battery backup and surge
protection; plug your computer, monitor and other critical devices here.* Select outlets
(see Basic Operation section) will provide surge protection only; plug your printer and
other non-essential devices here.
* Your UPS is designed to support electronic equipment only. You will overload the
UPS if the total VA ratings for all the equipment you connect to the Battery Backup
Protected/Surge Protected outlets exceeds the UPS’s output capacity. To find your
equipment’s VA ratings, look on their nameplates. If the equipment is listed in amps,
multiply the number of amps by 120 to determine VA. (Example: 1 amp × 120 = 120
VA). If you are unsure if you have overloaded the Battery Backup Protected/Surge
Protected outlets, run a self-test (see “ON/OFF/TEST” Button description).
If the LINE POWER indicator light does not illuminate when the UPS is turned ON,
try the following:
1. Make sure that the UPS is plugged into a live AC outlet.
2. If your UPS has a sliding ON/OFF switch, place it back in the OFF position, wait
several seconds, then place it in the ON position again.
3. If your UPS had an ON/OFF button, you must press it for at least one second to start
the UPS. (A beep should sound when the UPS starts.)
4. If the UPS still does not start, contact Tripp Lite Tech Support for assistance.
Quick Installation
201004182 93-2292.indb 3 5/6/2010 11:30:36 AM
Product specificaties
Merk: | Tripp Lite |
Categorie: | UPS |
Model: | BC350 |
Kleur van het product: | Zwart |
Gewicht: | 1800 g |
Breedte: | 110 mm |
Diepte: | 184.9 mm |
Hoogte: | 104.9 mm |
Snoerlengte: | 1.8 m |
Gewicht verpakking: | 2290 g |
Breedte verpakking: | 139.7 mm |
Diepte verpakking: | 276.9 mm |
Hoogte verpakking: | 177.8 mm |
LED-indicatoren: | Ja |
Land van herkomst: | China |
Afmetingen verpakking (BxDxH): | 287 x 196 x 105 mm |
Certificering: | UL1778/CSA/NOM/Class B |
Geluidsalarm(en): | Ja |
Uitgangsvermogen: | 180 W |
Accu/Batterij oplaadtijd: | 4 uur |
Temperatuur bij opslag: | -15 - 50 °C |
Frequentie: | 60 Hz |
Gewicht (imperiaal): | 4.7 lbs |
Bedrijfstemperatuur, bereik: | 32 - 104 °F |
Relatieve luchtvochtigheid bij opslag (geen condensering): | 0 - 95 procent |
Afmetingen (B x D x H): | 203 x 127 x 76 mm |
(Buitenste) hoofdverpakking hoogte: | 391.2 mm |
(Buitenste) hoofdverpakking breedte: | 287 mm |
(Buitenste) hoofdverpakking brutogewicht: | 16960 g |
(Buitenste) hoofdverpakking lengte: | 596.9 mm |
Hoeveelheid per (buitenste) hoofdverpakking: | 8 stuk(s) |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: | 10037332210934 |
Surge energy rating: | 252 J |
Nominale input voltage: | 120 V |
Output power capacity: | 0.35 kVA |
Typische backup tijd op halve lading: | 10 min |
Typische backup tijd op volledige lading: | 2.5 min |
Hot-swap batterij: | Ja |
Netspanning, in bedrijf: | 120 V |
Heb je hulp nodig?
Als je hulp nodig hebt met Tripp Lite BC350 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Tripp Lite
15 November 2024
18 September 2024
20 Juni 2023
16 Juni 2023
13 Juni 2023
12 Juni 2023
3 Juni 2023
27 Mei 2023
12 Mei 2023
10 Mei 2023
Handleiding UPS
- LevelOne
- Minuteman
- Avocent
- Digitus
- Liebert
- V7
- Adj
- Conceptronic
- Altronix
- Emerson
- Middle Atlantic
- CyberPower
- AEG
- FSP/Fortron
- Vanson
Nieuwste handleidingen voor UPS
17 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
8 Juni 2025
8 Juni 2025
8 Juni 2025