Salus RX30RF Handleiding
Salus Niet gecategoriseerd RX30RF
Bekijk gratis de handleiding van Salus RX30RF (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 3 mensen. Heb je een vraag over Salus RX30RF of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

1
2
- MAIN -
AUTO ON OFF
- AUX -
MAIN LED
AUX LED
LED at Main/AuxOn/O SystemOpenTherm System
Relay O
Relay On
OpenTherm Boiler O
OpenTherm On
Factory reset in progress
Pairing to gateway mode is activated
Standby mode, not connected
Lost link with gateway
Lost link with all paired
devices (in Auto mode only)
Solid red
Solid green
Solid orange
Flashes red slowly
Flashes red quickly
Main LED ashes red
3 times every 5 sec
Volt-free Combi Boiler Control
OpenTherm Boiler Control
Main LED ashes red
4 times every 5 sec
Flashes orange slowly
when switch position
is at ON
Manual ON mode is disabled
by the administrator
Terminals description
Introduction
To ensure both safety and optimal performance, the RX30RF
receiver should be used in accordance with all relevant regulations.
This device is designed exclusively for indoor use and must not
be installed in environments exposed to extreme temperatures
or other harsh conditions. Keep the receiver completely dry; any
inadequate installation may cause damage or malfunction. Always
disconnect the power before cleaning and use a dry cloth only.
For safe operation, position the RX30RF receiver at a convenient height to
allow easy access. The device's maximum operating temperature is 50°C,
so avoid placing them in locations that may exceed this limit to prevent
overheating. Adhering to these guidelines will ensure the long-term
reliability and safety of the receiver.
Safety Information
This product complies with the essential requirements and other relevant
provisions of Directives GPSR 2023/988/EU, RED 2025/138/EU and RoHS
2017/2102/EU. The full text of the EU Declaration of Conformity is
available at the following internet address: www.saluslegal.com.
2405-2480MHz, <14dBm
Product Compliance
LED operationWiring and mounting
The RX30RF ZigBee receiver can be used for the wireless control
of boiler, pump or zone valves in a HVAC system. It provides two
channels relay on/o output and an OpenTherm interface, oering
modulating control to the boiler ow water temperature directly to
match the demand for the optimization of eciency and heating
control comfort. It can be paired with the ZigBee 3.0 Elypso room
thermostat EL600T and SuperQuiet TRV TRV3RF to support multiple
applications. The RX30RF should be mounted on a suitable location
that is both accessible for the connection of mains and control wiring,
and allows good reception of the RF signal from the ZigBee gateway.
1
2
34
- MAIN -
AUTO ON OFF
- AUX -
1s - Pair
10s - Factory reset
1s - Refresh
MAIN
Note: Press and hold for 10 seconds the
bottom left button to perform a factory reset.
Slide switches
On/O System:
Pair / Factory reset
button
Refresh button
Switch
AUX
AUTO
ONOFF
Relay output is
controlled via ZigBee
communications
Slide Position and Relay Outputs
Relay output is
always on
Relay output is
always o
MAIN
OpenTherm System:
Switch
AUX
AUTOONOFF
Slide Position and OT/+ interface (A-B) Outputs
OpenTherm max
CH water Setpoint
OpenTherm boiler o
(heat demand disabled)
OpenTherm
Control Setpoint
No function
Button functions
3
4
5
6
1
Loosen the screws on the
underside of the receiver.
Remove the backplate from the
front panel.
Fix the backplate to the wall,
following the direction as shown
above.
Wire up the backplate referring to
the applicable wiring diagram.
DIP Switches
1 2 3 4
ON
OFF
Change the DIP switch located
on the front panel to select the
system type.
Put the front panel back onto the
backplate by aligning the ttings
and pushing it in place then
securely fasten the screws.
Wiring diagrams
2
TerminalFunction
230V 50-60Hz
(AC input)
Main (Volt-free
Output)
AUX (Volt-free
Output)
OpenTherm
Interface
Incoming Mains - LIVE
Earth Parking
Incoming mains - Neutral
Main relay, Normally Open Contact
Main relay, Common Contact
Main relay, Normally Close Contact
Auxiliary relay, Normally Close Contact
Auxiliary relay, Normally Open Contact
Auxiliary relay, Common Contact
Wire to OpenTherm Boiler
EN
MANUAL
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development
SALUS Controls plc reserve the right to change specication,
design and materials of products listed in this brochure
without prior notice.
04/2026
www.saluscontrols.com
DE / NL: [email protected]
RO: [email protected]o
DK: Support@salus-controls.dk
Manufacturer:
SALUS Controls plc
Units 8-10, Northeld Business Park, Forge Way,
Parkgate Rotherham, S60 1SD, United Kingdom
Importer:
Salus Controls European Distribution sp.z o.o.
ul. Szamocka 8, piętro 6., 01 748 Warszawa, Poland
RX30RF
ZIGBEE RECEIVER
QUICK GUIDE
Product specificaties
| Merk: | Salus |
| Categorie: | Niet gecategoriseerd |
| Model: | RX30RF |
Heb je hulp nodig?
Als je hulp nodig hebt met Salus RX30RF stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Salus
16 September 2026
15 September 2026
5 September 2026
3 September 2026
2 September 2026
1 September 2026
1 September 2026
1 September 2026
1 September 2026
1 September 2026
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
16 September 2026
16 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026