QTX DM-X6 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor QTX DM-X6 (4 pagina's) in de categorie Verlichting. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
154.097 User ManualUK
DM-X6
Mini DMX PAR Controller
Item ref: 4. 715 09 UK
User Manual
154.097 User ManualUK
Introduction
Thank you for choosing the -X6 mini DMX PAR controller as part of your lighting control system DM .
This unit is designed to control DMX PAR fixtures with 3, 4, 5 or 6-colour (RGB+W+A+V) mixing.
Please read these instructions to gain the best results from this item and avoid damage through misuse.
Unpacking
Your -X6 should reach you in good condition and should be supplied with an appropriate mains adaptor. DM
If there are any signs of damage or items missing from the packaging, contact your dealer immediately.
Warning
To prevent risk of fire or electric shock, do not expose any components to rain or moisture.
Avoid any impact or extreme pressure to the housing or control surface.
No user serviceable parts inside - do not open the case. Refer all servicing to qualified service personnel.
Placement
The DM-X6 may be free standing on a stable surface or wall mounted by either hanging on screws with the
rear punch-holes or flush-mounting with the 4 front mounting holes.
Safety
• Check for correct mains voltage before connecting the D.C. adaptor
• Ensure DMX leads are good condition with no short connections or damaged plugs
Cleaning
• Use a soft dry or slightly damp cloth to clean the casing. Do not use strong solvents
• Periodically clear any debris from fader slots with a soft brush
Panel Layouts
1. RGBW channel faders AV/D
2. DMX Group buttons
3. Channel Mode button & indicators
4. Run Mode Select (Auto or Sound)
5. Blackout
6. Strobe
7. RGBW Colour Mix
8. Amber/Violet Mix
9. MAC Auto Programs
10. Speed control
11. Strobe Speed/Sound Sensitivity control
12. DMX out XLR
13. D.C. input jack
14. Power switch
Setting up
Connect all PAR lights to be controlled in a chain from DMX outputs to DMX using a good quality DMX leads
(XLRF-XLRM) and connect the DMX OUT connector (12) on the DM-X4 to the DMX input of the first PAR
light in the chain. Various DMX PAR lights may have different channel allocations and the DM-X4 can be set
to one of 6 modes to control these. The chart below shows the 6 modes with channel fader allocations.
Mode
F1
F2
F3
F4
F5
F6
For cans with DMX allocation
RGBD
Red
Green
Blue
Master
RGB cans + CH4 Master Dim
RGBWD
Red
Green
Blue
White
Master
RGBW cans + CH5 Master Dim
RGBWAD
Red
Green
Blue
White
Amber
Master
RGBWA cans + CH6 Master Dim
RGBW AV
Red
Green
Blue
Master
Amber
Violet
RGBW cans AV
DRGBWAV
Green
Blue
White
Amber
Violet
Red+M
RGBWAV cans CH1 UV/Master Dim
RGBWAVD
Red
Green
Blue
White
Amber
UV
RGBW cans with Master on CH7 AV
Note: RGBW D mode transmits 100% on CH7 to hold master dimming open. AV
Select the correct mode to match the type of PAR cans to be controlled. The above table gives examples of
fader 1- allocations and it important to try each mode to see which delivers the correct behaviour from the 6
lights that the DM-X6 is controlling Remember that there may be a choice of DMX modes on each type of .
PAR can and it is best to set all cans to a similar DMX mode. Selecting a mode that does not match the DMX
allocation of the fixture(s) may give unexpected and confusing results or may not work at all.
In addition, the DM-X6 can control 4 groups of lighting fixtures separately via the four Group buttons (2).
Each group of PAR lights should be set with the relevant start address as shown below.
Group
DMX start address
Pressing the “1 10” - Group button, engages Group 1
1
1
Pressing the “11 20” - Group button, engages Group 2
2
11
Pressing the “21 30” - Group button, engages Group 3
3
21
Pressing the “31 40” - Group button, engages Group 4
4
31
Multiple groups can be selected together to control simultaneously
Groups that are selected are indicated by a blue flashing LED and any controls from the DM-X6 will affect
the group(s) selected. When a particular group is switched out, any further fader movements will not affect
that group. This feature makes a multi-zone light show possible with selected groups operating from auto
programs or sound-activated (see below) and others with manual control or static colour.
Operation
Connect the supplied mains adaptor to the DC input of the DM-X6 3) and switch the power on (14) (1
For the selected group(s), moving the channel faders controls the amount of red, green, blue, white, amber
and ultra-violet light output of DMX PAR fixtures.
In addition to the 4 channel faders, the DM-X6 has a MIX fader (7) which allows fast access to RGBW colour
mixes in a single movement. For warm colours and UV content, an additional AV MIX slider (8) controls the
amount of amber and violet components in the output.
For strobe effects, pressing the Strobe button will perform a white flashing sequence with a rate of (6)
between 1Hz and 20Hz governed by the Strobe Speed/Sound Sensitivity slider (11). Moving the slider to
zero produces no strobe output. Releasing the Strobe button will return lights back to the previous state.


Product specificaties

Merk: QTX
Categorie: Verlichting
Model: DM-X6

Heb je hulp nodig?

Als je hulp nodig hebt met QTX DM-X6 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Verlichting QTX

QTX

QTX Wash & Beam Handleiding

4 September 2023
QTX

QTX TetraCube Handleiding

4 September 2023
QTX

QTX BATPAR-18W Handleiding

4 September 2023
QTX

QTX TinyMover Handleiding

4 September 2023
QTX

QTX Recharge DJ Handleiding

4 September 2023
QTX

QTX Multi-Bar Handleiding

4 September 2023
QTX

QTX SpectraWash Handleiding

4 September 2023
QTX

QTX DP4 Handleiding

20 Juni 2023
QTX

QTX MBM-1 Handleiding

18 Juni 2023

Handleiding Verlichting

Nieuwste handleidingen voor Verlichting