PowerWalker VI 3000 CW Handleiding
Pagina's 6 Engels UPS
Bekijk de handleiding van PowerWalker VI 3000 CW gratis online of download de PDF. 23 mensen vonden deze handleiding nuttig. Vraag over dit model? Stel een vraag

ENGLISH
Quick Guide
PowerWalker VI CW Series
I.Setup Requirements
1.Leave sufficient space around for air circulation (recommended 10cm in front, 30cm
in the back and 30cm on sides)
2.-Keep ambient temperature below 40ºC. Between 4050ºC the UPS will gradually
derate the maximal Power reaching 70% at maximal 50ºC.
3.Install the UPS at maximum altitude of 1000m. Between 1000-5000m the UPS will
gradually derate the maximal Power reaching 65%at 5000m.
II.LCD Panel
Display
Function
Indicates the estimated backup time. H: hours, M: minute, S: second.
Indicates the configuration items
Indicates the warning and fault codes
Indicates that the UPS alarm is disabled.
Indicates the input voltage, input frequency, input current, battery voltage,
battery current, battery Power, ambient temperature, output voltage,
output frequency, load current and load percent.
Indicates the load level by 0----100%. 24%, 2549%, 5074% and 75
Indicates overload.
Indicates that programmable management outlets are working.
Indicates the UPS connects to the mains.
Parameter 1 Parameter 2
Product specificaties
| Merk: | PowerWalker |
| Categorie: | UPS |
| Model: | VI 3000 CW |
| Kleur van het product: | Zwart |
| Gewicht: | 22300 g |
| Breedte: | 145 mm |
| Diepte: | 455 mm |
| Hoogte: | 220 mm |
| Geluidsniveau: | 45 dB |
| Gewicht verpakking: | 22300 g |
| Breedte verpakking: | 235 mm |
| Diepte verpakking: | 540 mm |
| Hoogte verpakking: | 325 mm |
| Gebruikershandleiding: | Ja |
| LED-indicatoren: | Battery replacement, Fault |
| Vormfactor: | Tower |
| USB-poort: | Ja |
| Accu/Batterij voltage: | 12 V |
| RS-232 port: | 1 |
| Geluidsalarm(en): | Ja |
| Responstijd: | 10 ms |
| Uitgangsvermogen: | 2100 W |
| Batterij capaciteit: | 9 Ah |
| Accu/Batterij oplaadtijd: | 4 uur |
| Frequentie: | 50/60 Hz |
| Power factor: | 0.7 |
| Stekker: | C14 stekker |
| Efficientie: | 96 procent |
| Bedrijfstemperatuur (T-T): | 0 - 40 °C |
| Relatieve vochtigheid in bedrijf (V-V): | 20 - 95 procent |
| Type beeldscherm: | LCD |
| Code geharmoniseerd systeem (HS): | 85078000 |
| Aantal batterijcellen: | 4 |
| Aantal AC uitgangen: | 8 AC-uitgang(en) |
| Stroom (max.): | 1.4 A |
| Output power capacity: | 3 kVA |
| Ingang operation voltage (min): | 162 V |
| Ingang operation voltage (max): | 290 V |
| Uitgang operation voltage (min): | 208 V |
| Uitgang operation voltage (max): | 240 V |
| Crest factor: | 3:1 |
| UPS-topologie: | Line-interactive |
| Typische backup tijd op halve lading: | 9 min |
| Typische backup tijd op volledige lading: | 2.3 min |
| Emergency Power Off (EPO): | Ja |
| Golfvorm: | Sinus |
| Noodstop-aansluiting (EPO): | Ja |
| Uitgangsfrequentieregeling: | ±1 Hz |
| Efficiëntie (On-line modus): | 88 procent |
| Laadstroom: | 1.4 A |
Heb je hulp nodig?
Als je hulp nodig hebt met PowerWalker VI 3000 CW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS PowerWalker
PowerWalker VFI 10000 AT Handleiding PowerWalker VFI 6000 ICT IoT Handleiding PowerWalker VFI 3000 RMG PF1 Handleiding PowerWalker VI 1200 CSW Handleiding PowerWalker VI 1000 RLP Handleiding PowerWalker VI 2000 CW Handleiding PowerWalker VI 1200 RLE Handleiding PowerWalker VI 1500 CSW Handleiding
Alle PowerWalker UPS handleidingen
Populair in UPS
PowerWalker VI 1000 MS Handleiding PowerWalker VFI 10000 CG PF1 Handleiding PowerWalker VI 800 CSW Handleiding
Handleiding UPS
Nieuwste handleidingen voor UPS
Apc Back-UPS Pro BX1350M Handleiding Apc Back-UPS Pro BN1350M2 Handleiding Conceptronic ZEUS03G Handleiding Conceptronic ZEUS02G Handleiding Conceptronic ZEUS01G Handleiding Bicker Elektronik IUPS-401 Handleiding Bicker Elektronik UPSIC-1205D Handleiding Bicker Elektronik UPSI-2406DP1 Handleiding CyberPower Smart App Sinewave PR3000RTXL2UN Handleiding Energenie EG-UPS-031 Handleiding