OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
<ORIGINAL>
Packaged Air-Conditioners
INDOOR UNIT
PEA-M180,200,250LAA
FOR USER
en
2
en
Contents
1. Safety Precautions.................................................................2
2. Parts Names ..........................................................................3
3. Operation ...............................................................................7
4. Timer ......................................................................................9
5. Emergency Operation for Wireless Remote-controller
(option)...................................................................................9
6. Filter Preparation ...................................................................9
7. Trouble Shooting .................................................................10
8. Specications.......................................................................11
Note:
The phrase ā€œWired remote controllerā€ in this operation manual refers only to the PAR-40MAA. If you need any information for the other remote controller,
please refer to the instruction book included in this box.
1. Safety Precautions
ā–ŗī˜ƒBeforeinstallingtheunit,makesureyoureadalltheī˜ƒā€œSafetyPrecautionsā€.
ā–ŗī˜ƒTheī˜ƒā€œSafetyPrecautionsā€ī˜ƒprovideveryimportantpointsregardingsafety.Makesureyoufollowthem.
ā–ŗ Please report to or take consent by the supply authority before connection to the system.
MEANINGSOFSYMBOLSONTHEUNIT
WARNING
(Riskofre)
This symbol is only for R32 refrigerant. The type of the refrigerant used is written on the nameplate on the outdoor unit.
R32refrigerantisī˜ƒī›€ammable.Iftherefrigerantleaks,orcomesincontactwithreorpartsthatgenerateheat,itmaycreate
harmfulgasandposeariskofre.
Read the OPERATION MANUAL carefully before operation.
Service personnel are required to carefully read the OPERATION MANUAL and INSTALLATION MANUAL before operation.
FurtherinformationisavailableintheOPERATIONMANUAL,INSTALLATIONMANUAL,andthelike.
Symbols used in the text
Warning:
Describesprecautionsthatshouldbeobservedtopreventdanger
of injury or death to the user.
Caution:
Describesprecautionsthatshouldbeobservedtopreventdamage
to the unit.
Symbols used in the illustrations
: Indicates a part which must be grounded.
Warning:
ā€¢ī˜ƒ Theseappliancesarenotaccessibletothegeneralpublic.
• The unit must not be installed by the user. Ask the dealer or an
authorized company to install the unit. If the unit is installed
improperly,waterleakage,electricshockorremayresult.
• Do not stand on, or place any items on the unit.
ā€¢ī˜ƒ Donotsplashwaterovertheunitanddonottouchtheunitwith
wethands.Anelectricshockmayresult.
ā€¢ī˜ƒ Donotspraycombustiblegasclosetotheunit.Firemayresult.
ā€¢ī˜ƒ Donotplaceagasheateroranyotheropen-ameappliance
whereitwillbeexposedtotheairdischargedfromtheunit.
Incomplete combustion may result.
ā€¢ī˜ƒ Donotremovethefrontpanelorthefanguardfromtheoutdoor
unitwhenitisrunning.
ā€¢ī˜ƒ Whenyounoticeexceptionallyabnormalnoiseorvibration,stop
operation,turnoó°€Øī˜ƒthepowerswitch,andcontactyourdealer.
ā€¢ī˜ƒ Neverinsertngers,sticksetc.intotheintakesoroutlets.
ā€¢ī˜ƒ Ifyoudetectoddsmells,stopusingtheunit,turnoó°€Øī˜ƒthepower
switchandconsultyourdealer.Otherwise,abreakdown,electric
shockorremayresult.
ā€¢ī˜ƒ ThisairconditionerisNOTintendedforusebychildrenorinrm
personswithoutsupervision.
ā€¢ī˜ƒ Youngchildrenmustbesupervisedtoensurethattheydonot
playwiththeairconditioner.
ā€¢ī˜ƒ Iftherefrigerationgasblowsoutorleaks,stoptheoperationof
theairconditioner,thoroughlyventilatetheroom,andcontact
your dealer.
ā€¢ī˜ƒ Wheninstalling,relocating,orservicingtheairconditioner,
useonlythespeciedrefrigerantwrittenontheoutdoorunitto
chargetherefrigerantlines.Donotmixtherefrigerantwithany
otherrefrigerant,anddonotallowairtoremaininthelines.
- Ifairismixedwiththerefrigerant,thenitmaycauseabnormalhigh
pressureintherefrigerantlines,resultinginanexplosionandother
hazards.
- Theuseofanyrefrigerantotherthanthatspeciedforthe
systemwillcausemechanicalfailure,systemmalfunction,or
unitbreakdown.Intheworstcase,thiscouldleadtoaserious
impediment to securing product safety.
- It may also be in violation of applicable laws.
- MITSUBISHI ELECTRIC CORPORATION cannot be held
responsible for malfunctions or accidents resulting from the use of
the wrong type of refrigerant.
ā€¢ī˜ƒ Thisindoorunitshouldbeinstalledinaroomwhichisequal
toorlargerthantheī˜ƒī›€oorspacespeciedintheoutdoorunit
installation manual. Refer to the outdoor unit installation manual.
• Only use means recommended by the manufacturer to accelerate
thedefrostingprocessortoclean.
• This indoor unit shall be stored in a room that has no
continuously-operatingignitiondevicesuchasopenī˜ƒī›€ame,gas
appliance, or electrical heater.
ā€¢ī˜ƒ Donotpierceaholeinorburnthisindoorunitorrefrigerant
lines.
ā€¢ī˜ƒ Beawarethattherefrigerantmaybeodour-free.
3
en
1. Safety Precautions
Caution:
• Do not use any sharp object to push the buttons, as this may
damagetheremotecontroller.
•
Neverblockorcovertheindoororoutdoorunit’sintakesoroutlets.
Disposingoftheunit
Whenyouneedtodisposeoftheunit,consultyourdealer.
2. Parts Names
ā– ī˜ƒ IndoorUnit
PEA-MĀ·LAA
Fan steps 4 steps
Vane –
Louver –
Filter Optional parts