Hisense AMD-25UX4RAL8 Handleiding


Pagina's 20 Airco

Bekijk de handleiding van Hisense AMD-25UX4RAL8 gratis online of download de PDF. Deze handleiding is 0 keer bekeken. Vraag over dit model? Stel een vraag

Thank you very much for purchasing this Air Conditioner. Please
read this carefully before installing
use and installation instructions
use and installation instructions
use and installation instructions
use and installation instructionsuse and installation instructions
and using this appliance. And keep this manual for future reference.
Factory model
AMD-09UX4RAL4 AMD-25UX4RAL4
ADT-12UX4RBL4 AMD-35UX4R
ADT-18UX4RCL4 AMD-50UX4RCL4
AMD-24UX4RCL4 AMD-71
Contents
Caution Statements.........................................................1
Safety Precautions..........................................................3
Composition of the Air Conditioner..................................8
Operation Manual
Special Remarks.............................................................8
Troubleshooting...............................................................9
Filter Cleaning...............................................................10
1. Safety Notice...................................................................11
2. Tools and Instruments for Installation.............................12
3. Installation of the Indoor Unit .........................................12
3.1 Initial Check............................................................12
3.2 Installation..............................................................13
4. Refrigerant Pipe..............................................................14
4.1 Pipe Material...........................................................14
4.2............................................14
Connection of the Pipe
5. Drain Piping....................................................................15
6. Electrical Wiring..............................................................16
6.1 General Check........................................................16
6.2 Change of Static Pressure......................................17
6.3 Electrical Installation...............................................18
7. Test Run..........................................................................18
: The symbol refers to a hazard which can result in severe personal injury or death.
: The symbol refers to a hazard or an unsafe practice which may result in severe personal injury
or death.
: The symbol refers to a hazard or an unsafe practice which may result in personal injury,
product or property damage.
: It refers to the remarks and instruction to the operation, maintenance, and service.
DANGER
WARNING
CAUTION
NOTE
Alert Symbols
:
This air conditioner should be installed properly by qualified personnel in accordance with the installation
instructions provided with the unit.
Before installation, check if the voltage of the power supply is the same as the voltage at installation site
shown on the nameplate.
You must not carry on any transformation to this product, otherwise, it may cause
water leakage, breakdown, short-circuit, electric shock, fire, and so on.
Piping, welding and other such works should be carried out far away from the
flammable explosive material vessels, including the air conditioner refrigerant, to
guarantee the security of the site.
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit
where sea water can splash directly onto it or in sulphurous air near a spa. Do not
install the air conditioner where excessively high heat-generating objects are placed.
DANGER
WARNING
If the supply cord is damaged, it must be replaced by the factory or its service
department in case of danger.
The place where this product is installed must have the reliable electrical grounding
facility and protection. Please do not connect the grounding of this product to various
kinds of air-feeding ducts, drain piping, lightning protection facility as well as other
piping lines to avoid receiving an electric shock and damages caused by other factors.
Wiring must be done by a qualified electrician. All the wiring must comply with the
local electrical codes.
Consider the capacity of the electric current of your electrical meter and socket
before installation.
CAUTION Statements
1
WARNING
The power wire where this product is installed is supposed to have the independent
leakage protective device and the electric current over-load protection device which
are provided for this product.
2
CAUTION Statements
Read this manual carefully before using this air conditioner. If you still have any
difficulties or problems, consult your dealer for help.
The air conditioner is designed to provide you with comfortable room conditions. Use
this unit only for its intended purpose as described in this instruction manual.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety.
Means for disconnection, which can provide full disconnection in all poles, must be
incorporated in the fixed wiring in accordance with the wiring rules.
Never use gasoline or other inflammable gas near the air conditioner, which is very
dangerous.
When the air conditioner operationis abnormal, such as burnt smell, deformation, fire
,
smoke, and so on, it is forbidden to continue usingthe air conditioner, the main power
switch of the air conditioner must be cut off immediately and the agent must be
contacted.
Do not turn the air conditioner on or off from the main power switch. Use the
ON/OFF operation button.
Do not stick anything into the air inlet and air outlet of both the indoor and outdoor
units. This is dangerous because the fan is rotating at a high speed.
Do not cool or heat the room too much if babies or invalids are present.
Details of type and rating of circuit breakers/ELB is detailed in outdoor instruction
manual.
The method of connection of the appliance to the electrical supply and interconnection
of separate components is detailed in the part below.
The wiring diagram with a clear indication of the connections and wiring to external
control devices and supply cord is detailed in part below. The cord of the H07RN-F
type or the electrically equivalent type must be used for power connection and
interconnection between outdoor unit and indoor unit. The size of the cord is detailed
in part below.
The information of dimensions of the space necessary for correct installation of the
appliance including the minimum permissible distances to adjacent structures is
detailed in part below.
The range of external static pressures for ducted appliances is detailed in part below.
WARNING
CAUTION
●
Storage condition: Temperature -25~60
℃
Humidity 30%~80%
NOTE
: