Bekijk gratis de handleiding van Klein Tools VDV512-007 (5 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 59 mensen en kreeg gemiddeld 4.9 sterren uit 30 reviews. Heb je een vraag over Klein Tools VDV512-007 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/5

Probador de continuidad coaxial de bolsillo
Testeur de continuité de poche pour câble coaxial
VDV512-007
AAA
Battery included
Batería incluida
Pile comprise
RG59
RG6
RG6Q

3
1
5
7
11
9
10
6
4
8
2
ENGLISH
1. Test Remote
2. Power-off button (inside)
3. F-Connector
4. F-Adapter (Included)
5. Tester Body
6. Tester Head
7. AAA Battery (Included)
8. Buzzer
9.
LED Indicator #1
10.
LED Indicator #2
11. Pocket Clip
NOTE: There are no
user-serviceable
parts inside tester.
1. Transmisor remoto de prueba
2. Botón de apagado (interior)
3. Conector F
4. Adaptador F (incluido)
5. Cuerpo del probador
6. Cabeza del probador
7. Batería AAA (incluida)
8. Zumbador
9.
Indicador LED N.° 1
10.
Indicador LED N.° 2
11. Pocket Clip
NOTA: El probador no
contiene en su interior piezas
que el usuario pueda reparar.
1. Capteur de test à distance
2. Bouton d’arrêt (à l’intérieur)
3. ConnecteurF
4. Adaptateur F (compris)
5. Boîtier du testeur
6. Tête du testeur
7. PileAAA (comprise)
8. Indicateur sonore
9.
VoyantDEL no1
10.
VoyantDEL no2
11. Agrafe pour poche
REMARQUE: Ce testeur
ne contient aucune pièce
réparable par l’utilisateur.
ESPAÑOL
FRANÇAIS

ENGLISH
GENERAL SPECIFICATIONS
The Klein Tools VDV512-007 Pocket Coax Continuity Tester identifies and
verifies proper continuity of F-connector terminated coaxial cables. The tester
and remote allows cable runs between two different locations to be identified
and tested with status (wired properly, short or open) indicated via a buzzer
and colored LED indicators.
• Operating Altitude: 10000 ft. (3000 m) maximum
• Operating Temperature: ° ° ° °32 to 122 F (0 to 50 C)
• Storage Temp: ° ° ° °-4 to 140 F (-20 to 60 C)
• Relative Humidity: 10% to 90% non-condensing
• Dimensions: 5.0" x 1.25" x 0.75" (127 x 32 x 19 mm)
• Weight (including batteries): 4.8 oz. (136 g)
• Battery Type: AAA Alkaline
Specifications subject to change.
TESTING CABLES
NOTE: Not for use on powered circuits or outlets.
1. Unscrew test remote
1
from Pocket Coax Continuity Tester.
2. Connect test remote to one end of cable to be tested.
3. Connect F Connector on Pocket Coax Continuity Tester
3
to opposite
end of cable, using included F Adapter
4
if necessary. Response will
occur on contact:
CABLE STATUS LED #1 LED #2 BUZZER
Wired Correctly Green Green Yes
Short Red NoNone
Open Fault None None No
NOTE: To optimize battery life, keep remote docked when tester is not
in use.
BATTERY REPLACEMENT
If the tester fails to respond when connected to a cable with a known status, the
battery must be replaced.
1. Holding the tester body
5
firmly, grasp tester head
6
and unscrew
(turn counter-clockwise).
NOTE: DO NOT unscrew using F Connector, as
damage may occur. Use hands only, as use of tools may damage tester.
2. Remove and recycle spent AAA battery
7
.
3.
Install new AAA battery, with the positive (+) side facing out of the tester as
shown.
4. Screw tester head back onto body and hand-tighten.
STORAGE
Remove the battery when the tester is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity.
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations. Please see www.epa.gov www.erecycle.org or for
additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069 1-877-775-5346
customerservice@kleintools.com www.kleintools.com
Product specificaties
Merk: | Klein Tools |
Categorie: | Meetapparatuur |
Model: | VDV512-007 |
Heb je hulp nodig?
Als je hulp nodig hebt met Klein Tools VDV512-007 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Klein Tools
14 April 2025
13 Januari 2025
13 Januari 2025
18 November 2024
12 November 2024
24 September 2024
21 September 2024
21 September 2024
18 Juni 2024
18 Juni 2024
Handleiding Meetapparatuur
- Sanwa
- Rotronic
- Duux
- Camille Bauer
- Motrona
- Laica
- Silvercrest
- Panasonic
- Kübler
- Teslong
- Stabila
- CSL
- CESYS
- LaCie
- Goobay
Nieuwste handleidingen voor Meetapparatuur
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025