Klein Tools MM6000 Handleiding


Bekijk gratis de handleiding van Klein Tools MM6000 (8 pagina’s), behorend tot de categorie Multimeter. Deze gids werd als nuttig beoordeeld door 14 mensen en kreeg gemiddeld 4.3 sterren uit 3 reviews. Heb je een vraag over Klein Tools MM6000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/8
ENGLISH
Instruction
Manual
ENGLISH
MM6000


RANGE







4007036

~


-

AT

O
.L.

Apo




MIN

M
AX

%

V

A

Ω

F


n

-9
µ


m

-3
k

3
M

°F

°C

A- HOLD

LOW
Z




600mV
˜
600V0.1mV
˜
0.1V± (0.2% + 5 digits)
1000V1V± (0.5% + 10 digits)
 1000V : >10MΩ, <100pF
: >3kΩ, <200pF, up to 600V RMS



40Hz ~ 400Hz

400Hz ~ 2kHz
600mV0.1mV
± (0.75% + 5 digits)
± (2.5% +10 digits)
6V ~ 600V1mV ~ 0.1V ± (2.0% + 8 digits)
1000V1V± (0.75% + 8 digits)± (2.0% +8 digits)*
Continued on next page.
 1000V RMS : >10MΩ, <100pF
: >3kΩ, <200pF, up to 600V RMS
 40 to 2kHz True RMS
*Accuracy for 400Hz ~ 1kHz range only.


600μA ~ 400mA0.1μA ~ 0.1mA± (1.0% + 5 digits)
6A ~ 10A1mA ~ 10mA± (1.5% + 5 digits)
400mA (F440mA/1000V fuse) /10AF11A/1000V fuse)



40Hz ~ 2kHz
600μA ~ 400mA0.1μA ~ 0.1mA± (1.2% + 5 digits)
6A ~ 10A1mA ~ 10mA± (1.8% + 5 digits)
400mA (F440mA/1000V fuse) /10AF11A/1000V fuse)
 40 to 2kHz  True RMS


600Ω
˜
6MΩ0.1Ω
˜
0.001MΩ ± (1.0% + 5 digits)
50MΩ0.01MΩ± (1.5% + 10 digits)
 600V RMS


60nF0.01nF
± (3.5% + 6 digits)
600nF ~ 6000μF0.1nF ~ 1μF
600V RMS


99.99Hz
˜
399.9kHz0.01Hz
˜
0.1kHz± (0.1% + 3 digits)
 600V RMS  2.5V RMS


1.0
˜
99.0%0.1%± (0.2% per kHz + 0.1% + 8 digits)
 600V RMS Sensitivity: < 50V RMS
 0.5Hz to 10kHz


600V RMS6.0V DC0.25mA
<
1.8V DC


600V RMS
<
0.44V<40Ω


-58 ~ 600°F0.1°F± (1.0% + 5.4°F)
-50 ~ 600°C0.1°C± (1.0% + 3.0°C)
600 ~ 1832°F1°F± (1.0% + 5.4°F)
600 ~ 1000°C1°C± (1.0% + 3.0°C)
 600V RMS  Not specifi ed
Specifi cations subject to change.


CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifi cations section, allow the instrument to return to normal operating
conditions before using it.

Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations
.
Prior to disposal of this product, please contact Klein Tools
for proper disposal options.


•Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000°C).

Features:
REL

•When selecting uA or mA/A functions the meter will indicate
” if the test leads are not properly connected to the meter.
•Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.

450 Bond Street
Lincolnshire, IL 60069



Rev 04/14 B 139750

Features:



•Press SELECT to choose AC or DC Voltage.
•Use Low Impedance (LOW Z) mode to reduce ghost voltages.
•See AC/DC Voltage instruction.
Capacitance Features:



•Reading may take up to 60 seconds
for large capacitors.

1000V
10A
Dwg Name:MM6000-139750ART Dwg No:139750
ECO No:016671 Pkg Dwg Ref:1650Rev: B
Color Reference:CEN-PACK-003-A
MM6000-139750ART-Instructions.indd 1-45/5/14 10:19 AM

Beoordeel deze handleiding

4.3/5 (3 Beoordelingen)

Product specificaties

Merk: Klein Tools
Categorie: Multimeter
Model: MM6000

Heb je hulp nodig?

Als je hulp nodig hebt met Klein Tools MM6000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden