Bekijk gratis de handleiding van Klein Tools CL700 (48 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 31 mensen en kreeg gemiddeld 5.0 sterren uit 16 reviews. Heb je een vraag over Klein Tools CL700 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/48
INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 33
ESPAÑOL pg. 17
600A AC Aut
Digital Clam
Ω
True RM
Measurem
Technolog
NON-CONTACT
VOLTAGE METER
LOW IMPEDANCE
DATA & RANGE
HOLD
AUDIBLE CONTINUITY
DIODE TEST
CAPACITANCE &
FREQUENCY
4007177
CL700
2
m
-14° –
1000°F
(-26° –
538°C)
IP40
2
GENERAL SPECIFICATIONS
Klein Tools CL700 is an automatically ranging true root mean square
(TRMS) digital clamp-meter that measures AC current via the clamp,
and measures AC/DC voltage, resistance, continuity, frequency,
capacitance, and tests diodes via test-leads, and temperature via a
thermocouple probe. It also features a Low Impedance (LoZ) mode
for identifying and eliminating ghost or stray voltages.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <80% non-condensing
Operating Temp: ° ° ° °32 to 104 F (0 to 40 C)
Storage Temp: ° ° ° °14 to 140 F (-10 to 60 C)
Accuracy: Values stated at 65° to 83°F (18° to 28°C)
Temp Coefcient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
Dimensions: 9.09" x 3.82" x 1.54" (231 x 97 x 39 mm)
Weight: 11.8 oz. (335 g) including batteries
Calibration: Accurate for one year
Standards: Conforms to: UL STD 61010-1, 61010-2-032,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-032, 61010-2-033.
IEC EN 61010-1, 61010-2-032,
61010-2-033, 61326-1.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Drop Protection: 6.6 ft. (2m)
Safety Rating: CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy (50/60 Hz)
AC Voltage
(V AC)
6.000V 1mV ±(1.5% + 5 digits)
60.00V 10mV ±(1.2% + 5 digits)
600.0V 100mV
1000V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
600mV 0.1mV ±(1.0% + 8 digits)
6.000V 1mV
±(1.0% + 3 digits)60.00V 10mV
600.0V 100mV
1000V 1V ±(1.2% + 3 digits)
Input Impedance: Frequency Range:10MΩ 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
AC Current
(A AC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
Frequency Range: 50 to 60Hz
Function Range Resolution Accuracy
Resistance
600.0Ω 0.1Ω
±(1.5% + 5 digits)
6.000KΩ 1Ω
60.00kΩ 10Ω
600.0kΩ 10
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 10 digits)
Maximum Input: 600V AC RMS or 600V DC
Capacitance
60.00nF 0.010nF ±(5.0% + 35 digits)
600.0nF 0.1nF
±(3.0% + 5 digits)6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF ±(5.0% + 5 digits)
6000µF 1µF
Maximum Input: 600V AC RMS or 600V DC
Temperature
(Fahrenheit)
-14° to 32°F
0.1 to 1
°F
±(2.0% + 9
°F
)
33° °F to 752
±(1.0% + 5.4
°F
)
753° °F to 1000
±(2.0% + 9
°F
)
Temperature
(Celsius)
-2to C
0.1 to 1
°C
±(2.0% + 5
°C
)
1° to 40C
±(1.0% + 3
°C
)
40to 538°C
±(2.0% + 5
°C
)


Product specificaties

Merk: Klein Tools
Categorie: Meetapparatuur
Model: CL700

Heb je hulp nodig?

Als je hulp nodig hebt met Klein Tools CL700 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden