Juice Goose SQ-1500 Handleiding


Bekijk gratis de handleiding van Juice Goose SQ-1500 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 3.6 sterren uit 3.5 reviews. Heb je een vraag over Juice Goose SQ-1500 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
OWNER’S
MANUAL
SQ-1500
SEQUENCED POWER CONTROL MODULE
02-14
The Juice Goose SQ-1500 is a three step power sequence device that
will distribute AC power to as many as seven pieces of equipment with
total current requirements of less than 15 amps.
When activated, either locally with the switch on the front of the chas-
sis or by remote contact with a latching contact closure, the switched
outlets turn on in three sets, or “PODS”, of two outlets - with a stan-
dard delay of two seconds between each turn on event. When se-
quenced down the outlets turn off in reverse order from the turn on.
Contact Juice Goose if a sequence delay other than two seconds is re-
quired.
SQ-1500
SEQUENCED POWER CONTROL MODULE
SAFETY PRECAUTIONS
SQ-1500 is designed to operate at 120 volts, 60 hertz. Operation
with any voltage or frequency other than that can damage the equip-
ment and create an unsafe situation.
CAUTION #1: The SQ-1500 must be grounded. If a power extension
cord is required, use a properly insulated and grounded cord. Failure
to ground the device could expose the user to dangerous electric
shock.
CAUTION #2: There are no user serviceable parts inside the SQ-1500.
Do not open the chassis. Refer all service questions or issues to
Juice Goose or a qualified technician.
CAUTION #3: Do not expose the SQ-1500 to moisture or salty air.
Doing so could cause significant damage and create an unsafe condi-
tion.
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for any
losses, damage, or injury resulting directly or indirectly from the use
of a SQ-1500 device in a manner contrary to accepted safe operating
methods or any instructions contained in this document. The user
should determine prior to use whether this product is adequate, suit-
able and safe for the application intended. Since individual applica-
tions can be subject to extreme variation Juice Goose makes no rep-
resentation or guarantee as to the suitability of the SQ-1500 for any
generally described application.
SPECIFICATIONS
CHASSIS……………………………………………………...................................................................…………………...16 Gauge Steel
DIMENSIONS (inches)………………….....................................................................……………….....………...1.72H x 19.0W x 7.0D
WEIGHT (lbs)......………………………………………………………………...................................................................................……..10.0
CIRCUIT BREAKER ………………………………..................................................................……………..Back Panel, 15A Thermal
POWER INPUT ………..………...............................................................……………...7 Foot, 14/3 SJT with NEMA 5/15P Plug
VOLTAGE INPUT.………………………………………………..............................................................…………...120 VAC at 60 Hz
POWER OUTPUTS
........................................................................Six NEMA 5/15R (Sequenced) and One NEMA 5/15R (Unswitched)
RELAY CURRENT RATING……………..................................................................……..............................................……………………...30A
POWER LINE FILTRATION…………….............................................................…………Multi-stage Filter (48dB at 30 MHz)
VOLTAGE SPIKE PROTECTION………………………………………..................................................................…….3 MOV Matrix
OPERATION
REMOTE CONTACT CLOSURE - The SQ-1500 remote control terminal
can be connected to a contact closure for remote operation. (See Re-
mote Switch Connection) Any latching switch or relay will work for
this purpose. Juice Goose recommends use of a double throw device
in order to maintain one of two contact closures at all times. Com-
puter controlled devices such as those produced by Crestron, AMX
and similar companies may be used to control the SQ-1500.
SEQUENCE SWITCH - Without a contact closure on the remote con-
trol terminal the sequence switch on the front left of the SQ-1500 will
control its operation. In the event of a failure of the SQ-1500 timing
control circuit, the Manual On switch on the front of the chassis al-
lows activation of the SQ-1500. (Note: the Manual On option does not
provide sequencing).
REMOTE SWITCH CONNECTION
The following instructions are provided to assist with connection of a
latching remote switch or relay to the five position terminal on the
back of the SQ-1500 chassis.
SINGLE POLE DOUBLE THROW
LATCHING SWITCH
In the above illustration Position 1 on the terminal should be con-
nected to the common pole on the SPDT switch or relay. Positions 4
and 5 should be connected to the other two poles. Closing Position 1
to Position 4 will begin a sequence DOWN. Closing Position 1 to Posi-
tion 5 will begin a sequence UP.


Product specificaties

Merk: Juice Goose
Categorie: Niet gecategoriseerd
Model: SQ-1500

Heb je hulp nodig?

Als je hulp nodig hebt met Juice Goose SQ-1500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden