Haws 8317CTFP Handleiding


Bekijk gratis de handleiding van Haws 8317CTFP (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 7 mensen en kreeg gemiddeld 4.6 sterren uit 4 reviews. Heb je een vraag over Haws 8317CTFP of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
2172mm
85-1/2"
95-1/2"
2426mm
TRACED AND INSULATED
SUPPLY MUST BE HEAT
IMPORTANT
3/4" NPT JUNCTION BOX
POWER CONNECTION
MOUNTING LOCATION
FOR OPTIONAL
41-3/4"
1060mm
FLOOR LINE
7"
178mm
REMOVABLE
ABS JACKET
171mm
6-3/4"
927mm
36-1/2"
2299mm
90-1/2"
MOUNTING LOCATION
AREA LIGHT
FOR OPTIONAL
Ø3/8"
30°
B.C.
Ø8"
Ø203mm
Ø10mm
3X
Ø9"
Ø229mm
TO A BOTTOM SUPPLY UNIT.
IN THE OPERATION & MAINTENANCE
MANUAL (PAGE 2) TO CONVERT
OF THE INSTALLATION PROCEDURE
TOP SUPPLY SHOWN. SEE STEP 2
1-1/4" IPS SUPPLY UNION (INLET)
1098mm
43 1/4"
6 3/4"
171mm
14"
355mm
20-1/2"
521mm
67-1/4"
1708mm
NOTES:
1. DIMENSIONS MAY VARY BY ± 1/2 INCH [13mm].
2. TO COMPLY WITH ANSI Z358.1-2009 FOR EMERGENCY EYEWASH OR EYE/FACE WASH AND SHOWER EQUIPMENT:
- UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTABLE PLUMBING PRACTICES.
- EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED WITH NOZZLES NOT LESS THEN 83.8 CM (33 IN.) AND NO GREATER THAN
114.3 CM (45 IN.) FROM SURFACE ON WHICH USER STANDS AND 15.3 CM (6 IN.) MINIMUM FROM WALL OR NEAREST OBSTRUCTION.
- SHOWER SHALL BE POSITIONED SO THAT SHOWER HEAD IS NOT LESS THAN 208.3 CM (82 IN.) NOR MORE THAN 243.8 CM (96 IN.)
FROM SURFACE ON WHICH USER STANDS.
- SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 50.8 CM (20 IN.) AT 152.4 CM (60 IN.) ABOVE SURFACE ON WHICH
USER STANDS, AND CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 40.6 CM (16 IN.) FROM ANY OBSTRUCTION.
3. DO NOT USE REGULAR PIPE SEALANT. IF NECESSARY USE DOW CORNING 832 SEALANT PLACING 5 SMALL
BEADS ON THE MALE THREADS, JUST ABOVE THE FIRST THREAD.
(NOTES CONTINUED ON SHEET 2 OF 4.)
3
6"
152mm
DRENCH HOSE
DRENCH HOSE ACTIVATION
VALVE ASSEMBLY
APPROVED:
DRAWN:
PART NUMBER
DRAWING NO.
SCALE:
SHEET OF
REV
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (755) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
RTM
03/29/05
15201A00
17
0002081781.D
8317CTFP(120V)/ 8317CTFP.220V
1/20
1 4
FV
10/21/14
FV
1 of 4
INSTALLATION
4921
2014
SP158B FREEZE PROTECTION VALVE
(SEE NOTES ON SHEETS 2 & 3 FOR
INSTALLATION INSTRUCTIONS.)
NOTE: PULL ROD AND HANDLE NOT
ASSEMBLED. ORIENTATION OF HANDLE
MUST BE IN UP POSITION WHEN FULLY
CLOSED AND PULL ROD INSERTED IN
HOLE SHOWN.
APPROVED:
DRAWN:
PART NUMBER
DRAWING NO.
SCALE:
SHEET OF
REV
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (755) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
VWC
12/2/12
15201A
17
0002081781.D
8317CTFP(120V) / 8317CTFP.220V
NA
2 4
FV
10/21/14
4632
HM
2 OF 4
INSTALLATION
4921
2014
VALVE, FREEZE (NO UNION) SP158B
CABLE-TIE, 15" / PN 0005972499
4
B
C
A
SP158B VALVE SHOWN CONNECTED TO BOTTOM UNION FOR
REFERENCE ONLY. VALVE CAN BE INSTALLED AT TOP OR BOTTOM.
UNION SURFACE
INNER TUBE W/ PLUGGED END
C
C
C
ADHESIVE SEAM C
RUBBER GROMMET
HEAT TRACE CABLEB
B
PLUGGED END
MALE SECTION OF UNION
(PART OF VALVE SUB-ASSY)
A
NOTES: (CONTINUED FROM SHEET 1 OF 4)
. FREEZE PROTECTION VALVE INSTALLATION INSTRUCTIONS:
INSTALL VALVE SUB-ASSEMBLY INTO FEMALE SECTION OF UNION AND TIGHTEN WATER-TIGHT.
FORM HEAT TRACE CABLE AROUND VALVE AND PLUG, APPLY 2X CABLE-TIES TO HEAT TRACE CABLE, AS SHOWN, ENSURING
THAT HEAT TRACE CABLE IS PRESSED FIRMLY AGAINST SIDES OF VALVE (PUSH ANY LOOSE HEAT TRACE CABLE BACK INSIDE
JACKET THROUGH RUBBER GROMMET). TRIM EXCESS CABLE-TIE STRAPPING.
SLIDE INNER TUBE W/ PLUGGED END OVER VALVE WITH ADHESIVE SEAM FACING BOTTOM AND NON-PLUGGED END OF TUBE
BUTTED UP AGAINST UNION SURFACE. REMOVE 2X ADHESIVE TAPE FROM SEAM AND SQUEEZE ADHESIVE SEAMS TOGETHER
AROUND VALVE. APPLY 2X CABLE-TIES TO TUBE, IN APPROXIMATE LOCATIONS SHOWN. TRIM EXCESS CABLE-TIE STRAPPING.
(NOTES CONTINUED ON SHEET 3 OF 4)
A
FEMALE SECTION OF UNION
(PART OF SHOWER UNIT)
A
BARBED CONNECTOR
D
JACKET SURFACE
(SEE SHEET 3.)
E
CABLE-TIE, 15" / PN 0005972499 B
C
APPROVED:
DRAWN:
PART NUMBER
DRAWING NO.
SCALE:
SHEET OF
REV
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (755) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
VWC
12/2/12
15201A 17
0002081781.D
8317CTFP(120V) / 8317CTFP.220V
NA
3 4
FV
10/21/14
4632
HM
3 OF 4
INSTALLATION
4921
2014
5.
D
SP158B VALVE SHOWN CONNECTED TO BOTTOM UNION FOR
REFERENCE ONLY. VALVE CAN BE INSTALLED AT TOP OR BOTTOM.
D
D
D
NOTES: (CONTINUED FROM SHEET 2 OF 4)
FREEZE PROTECTION VALVE INSTALLATION INSTRUCTIONS (CONTINUED):
WRAP OUTER TUBE OVER INNER TUBE ENCAPSULATED VALVE WITH ADHESIVE SEAM ORIENTED PERPENDICULAR
TO SEAM OF INNER TUBE. PUSH OUTER TUBE UP AGAINST JACKET SURFACE. WHEN TUBE IS MOUNTED FIRMLY
AGAINST JACKET SURFACE, SQUEEZE TUBE AT BARBED CONNECTOR SUCH THAT BARBED NIPPLE PUSHES
THROUGH OUTER TUBE WALL. (PUSHING CONNECTOR THROUGH WALL WILL EXTRUDE A CYLINDRICAL PLUG OF
TUBING TO BREAK FREE. DISCARD PLUG.) PUSH TUBE DOWN EVEN FURTHER SO THAT HOLE IN TUBE STRETCHES
AROUND HEXAGONAL BOSS OF CONNECTOR. SQUEEZE OUTER TUBE TIGHT UNTIL ADHESIVE SEAMS ARE CLOSE
ENOUGH TO SEAL. REMOVE PROTECTIVE TAPE AND SEAL SEAMS.
TO ENSURE PROPER INSULATION OF UNION; THERE MUST BE NO SPACE BETWEEN OUTER TUBE AND JACKET
SURFACE (SEE SHEET 2 FOR SURFACE CALLOUT). THEREFORE, SLICE TWO PLACES, TOP SIDE AND BOTTOM SIDE,
COMPLETELY THROUGH OUTER TUBE TO A LENGTH EQUAL TO DEPTH OF TRIM SEAL. FORCE SLICED TUBE
AROUND TRIM SEAL AND PUSH TUBE TIGHTLY AGAINST JACKET, AS SHOWN. APPLY 2X CABLE-TIE HEAD, AND 2X
CABLE-TIE STRAP, TO TUBE, IN APPROXIMATE LOCATIONS SHOWN. TRIM EXCESS STRAPPING.
BARBED CONNECTOR
D
PERPENDICULAR
ADHESIVE SEAM
D
OUTER TUBE
HEAD, 2-PC CABLE-TIE / PN 0002850165
STRAP, 2-PC CABLE-TIE, 20" L
E
INNER TUBE INSULATION SEAM
D
SLICED TUBE SECTION
(TOP SIDE)
E
JACKET/TUBE
INTERSECTION
E
TRIM SEAL E
SLICED TUBE SECTION
(BOTTOM SIDE)
E


Product specificaties

Merk: Haws
Categorie: Niet gecategoriseerd
Model: 8317CTFP

Heb je hulp nodig?

Als je hulp nodig hebt met Haws 8317CTFP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden