First Alert CO1 Handleiding


Pagina's 2 Gasmelder

Bekijk de handleiding van First Alert CO1 gratis online of download de PDF. Deze handleiding is 0 keer bekeken. Vraag over dit model? Stel een vraag

®
SC2/SM2/CO1Series120V
Smoke,Combination,&
CarbonMonoxideAlarms
GettingStartedGuide
EverythingyouneedisOnline!
Install,operate,andmaintainyouralarmusingeasy-
to-followmobiledocumentationwithinstructional
videos.
followingURL:info.firstalert.com/sc2-sm2-im
ThisManualCoversTheFollowingModels
ModelTypeBatteryBackup
SM2-W01&SM2-W01ASmokeAABattery
SM2-W10&SM2-W10ASmoke10-YearSealed
SC2-W01&SC2-W01ASmoke/COAABattery
SC2-W10&SC2-W10ASmoke/CO10-YearSealed
C01-W01&C01-W01ACOAABattery
IMPORTANT!PLEASEREADCAREFULLY&
SAVEFORFUTUREREFERENCE
Thewarnings/limitationsinthismanualcontainsimportantinformation
aboutyourAlarm’soperation.
MUSTBEREPLACEDEVERY10YEARS!
BasicSafetyInformation
IMPORTANT:
l
Dangers,Warnings,andCautionsalertyoutoimportantoperating
instructionsortopotentiallyhazardoussituations.Payspecial
attentiontotheseitems.
l
ThisSmoke/COAlarmisapprovedforuseinsingle-family
residences.ItisNOTdesignedformarineorRVuse.
!
WARNING!
ThiscombinationSmoke/CarbonMonoxide(CO)Alarmhastwo
separatealarms.THISCARBONMONOXIDEALARMINGDEVICEIS
DESIGNEDTODETECTCARBONMONOXIDEGASFROMANY
SOURCEOFCOMBUSTION.ITISNOTDESIGNEDTODETECT
SMOKE,FIRE,ORANYOTHERGASESUNLESSTHEPRODUCTHAS
BEENINVESTIGATEDANDDETERMINEDTOCOMPLYWITHTHE
APPLICABLEREQUIREMENTS.THISDEVICEWILLONLYINDICATE
THEPRESENCEOFCARBONMONOXIDEGASATTHESENSOR.
CARBONMONOXIDEGASMIGHTBEPRESENTINOTHERAREAS.
TheSmokeAlarmwillonlyindicatethepresenceofsmokethat
reachesthesensor.TheSmokeAlarmisnotdesignedtosensegas,
heatorflames.
DANGER!
ELECTRICALSHOCKHAZARD
TurnoffthepowertotheareawheretheAlarmisinstalledbefore
removingitfromthemountingbracket.Failuretoturnoffthe
powerfirstmayresultinseriouselectricalshock,injuryordeath.
!
WARNING!
l
Thisunitwillnotalerthearingimpairedresidents.Itis
recommendedthatyouinstallspecialunitswhichusedevices
likeflashingstrobelightstoalerthearingimpairedresidents.
l
Installationofthisunitmustconformtotheelectricalcodesin
yourarea;Articles210and300.3(B)ofNFPA70(NEC),NFPA
72,NFPA101;SBC(SBCCI);UBC(ICBO);NBC(BOCA);OTFDC
(CABO),andanyotherlocalorbuildingcodesthatmayapply.
Wiringandinstallationmustbeperformedbyalicensed
electrician.Failuretofollowtheseguidelinesmayresultin
injuryorpropertydamage.
l
NeverdisconnectthepowerfromanACpoweredunittostop
anunwantedalarm.Doingsowilldisabletheunitandremove
yourprotection.Inthecaseofatrueunwantedalarmopena
windoworfanthesmokeawayfromtheunit.Thealarmwill
resetautomaticallywhenitreturnstonormaloperation.
l
Thisunitmustbepoweredbya24-hour,120VACpuresine
wave60Hzcircuit.Besurethecircuitcannotbeturnedoffby
aswitch,dimmer,orgroundfaultcircuitinterrupter.Failureto
connectthisunittoa24-hourcircuitmaypreventitfrom
providingconstantprotection.
l
ThisAlarmmusthaveACorbatterypowertooperate.Ifthe
ACpowerfails,batteryback-upwillallowthealarmtosound
foratleast4minutes.IfACpowerfailsandthebatteryis
weak,protectionshouldlastforatleast7days.IfACpower
failsandthebatteryisdeadormissing,thealarmcannot
operate.
l
ConnectthisunitONLYtoothercompatibleunits.See"HOW
TOINSTALLTHISSMOKE/COALARM"fordetails.Donot
connectittoanyothertypeofalarmorauxiliarydevice.
Connectinganythingelsetothisunitmaydamageitorprevent
itfromoperatingproperly.
l
ThisSmoke/COAlarmhasabatterydrawerwhichresists
closingunlessabatteryisinstalled.Thiswarnsyoutheunit
willnotoperateunderDCpowerwithoutabattery.
l
Donotstandtooclosetotheunitwhenthealarmissounding.
Itisloudtowakeyouinanemergency.Exposuretothehornat
closerangemayharmyourhearing.
l
Donotpaintovertheunit.Paintmayclogtheopeningstothe
sensingchambersandpreventtheunitfromoperating
properly.
01
Introduction
ThankyouforchoosingFirstAlert
®
foryourSmoke&CarbonMonoxideAlarm
needs.Youhavepurchasedastate-of-the-artSmoke&Smoke/Carbon
MonoxideAlarmdesignedtohelpprovideyouwithearlywarningofasmoke
and/orcarbonmonoxidedanger.Pleasetakethetimetoreadthismanualand
maketheSmoke&CarbonMonoxideAlarmanintegralpartofyourfamily’s
safetyplan.
AllFirstAlert
®
SmokeAlarmsconformtoregulatoryrequirements,including
ULCSTDS531andaredesignedtodetectparticlesofcombustion.All
modelsconformtoandarelistedUL217(Smoke)andUL2034(CO).All
smokedetectorsusePhotoelectrictechnology.Smokeparticlesofvarying
numberandsizeareproducedinallfires.
IMPORTANT:Thereplacementdatethatappearsonthedeviceisthedate
beyondwhichthedevicemaynolongerdetectcarbonmonoxideaccurately
andshouldbeimmediatelyreplaced.
Placement
FollowNFPA70,NFPA72,C22.1-12,andULC553forplacementandwiring
methods.Forfulldetails,visitnfpa.orgorscantheQRcodeabove.
!
WARNING!
Installationofthedeviceshouldnotbeusedasasubstituteforproper
installation,use,andmaintenanceoffuel-burningappliances,including
appropriateventilationandexhaustsystems.
WhereToInstallThisAlarm
MinimumcoverageforSmokeAlarms,asrecommendedbytheNational
FireProtectionAssociation(NFPA),isoneSmokeAlarmoneveryfloor,in
everysleepingarea,andineverybedroom.
ForCOAlarms,theNationalFireProtectionAssociation(NFPA)
recommendsthataCOAlarmshouldbecentrallylocatedoutsideofeach
separatesleepingareaintheimmediatevicinityofthebedrooms.For
addedprotection,installadditionalCOAlarmsineachseparatebedroom,
andoneverylevelofyourhome.
RecommendedPlacement:
CO ALARMS
SMOKE ALARMS
KEY:
In new construction AC and AC/DC smoke alarms MUST be
interconnected to meet NFPA recommendations.
SC2-021-V0
InGeneral,InstallCombinationSmokeand
CarbonMonoxideAlarmsaccordingtonFPA72
recommendations:
FORYOURINFORMATION,THENATIONALFIREALARMAND
SIGNALINGCODE,NFPA72,READSASFOLLOWS:
29.8.1*RequiredSmokeDetection
29.8.1.1Whererequiredbyothergoverninglaws,codes,or
standardsforaspecifictypeofoccupancy,approvedsingleand
multiple-stationSmokeAlarmsshallbeinstalledasfollows:
1.
Inallsleepingroomsandguestrooms
2.
Outsideofeachseparatedwellingunitsleepingarea,within21
ft(6.4m)ofanydoortoasleepingroom,withthedistance
measuredalongapathoftravel
3.
Oneverylevelofadwellingunit,includingbasements
4.
Oneverylevelofaresidentialboardandcareoccupancy(small
facility),includingbasementsandexcludingcrawlspacesand
unfinishedattics
5.
Inlivingarea(s)ofaguestsuite
6.
Inthelivingarea(s)ofaresidentialboardandcareoccupancy
(smallfacility)
(ReproducedwithpermissionfromNFPA72®-2020,NationalFire
AlarmandSignalingCode®Copyright©2019,NationalFire
ProtectionAssociation.Thisreprintedmaterialisnotthecomplete
andofficialpositionoftheNFPAonthereferencedsubject,whichis
representedonlybythestandardinitsentiretywhichmaybe
obtainedthroughtheNFPAwebsiteatwww.nfpa.org.)(NFPA72®
andNationalFireAlarmandSignalingCode®areregistered
trademarksoftheNationalFireProtectionAssociation,Inc.,Quincy,
MA.)
Inaddition,adheretothefollowing:
l
Inthehallneareverysleepingarea.Ifahallismorethan40feet(12
meters)long,installaunitateachend.
l
Atthetopoffirst-to-secondfloorstairsandatthebottomofthe
basementstairs.
l
Foradditionalcoverage,installAlarmsinallrooms,halls,and
storageareas,wheretemperaturesnormallyremainbetween40˚F
and100˚F(4.4˚Cand37.8˚C).
l
See"AvoidingDeadAirSpaces"belowformoreinformationon
properplacementonwallsandceilings.
NOTE:Foranylocation,makesurenodoororotherobstructioncould
keepcarbonmonoxideorsmokefromreachingtheAlarm.
InstallingSmoke/COAlarmsInMobileHomes
ForminimumsecurityinstalloneSmoke/COAlarmasclosetoeach
sleepingareaaspossible.Formoresecurity,putoneunitineachroom.
Manyoldermobilehomes(especiallythosebuiltbefore1978)havelittle
ornoinsulation.Ifyourmobilehomeisnotwellinsulated,orifyouare
unsureoftheamountofinsulation,itisimportanttoinstallunitson
insidewallsonly.
WhereNotToInstallThisAlarm
ForBestPerformance,ItIsRecommendedYouAvoid
InstallingSmoke/COAlarmsInTheseAreas:
l
Shallnotbelocatedbehindfurniture,drapes,oranyotherobject
whereitmightnotbeseenorheard
l
Ingarages,furnacerooms,crawlspacesandunfinishedattics.
Avoidextremelydusty,dirtyorgreasyareas.
l
Wherecombustionparticlesareproduced.Combustionparticles
formwhensomethingburns.Areastoavoidincludepoorly
ventilatedkitchens,garages,andfurnacerooms.Keepunitsatleast
10feet(3meters)fromthesourcesofcombustionparticles(stove,
furnace,waterheater,spaceheater)ifpossible.Theplacement
recommendationsareintendedtokeeptheseAlarmsata
reasonabledistancefromafuel-burningsource,andthusreduce
“unwanted”Alarms.Ventilatetheseareasasmuchaspossible.
l
Within5feet(1.5meters)ofanycookingappliance.
l
Inextremelyhumidareas.ThisAlarmshouldbeatleast10feet(3
meters)fromhumidareas.
l
Indirectsunlight.
l
Inturbulentair,likenearceilingfansoropenwindows.Blowingair
maypreventsmokefromreachingthesensors.
NOTE:ThisAlarmshouldnotbeinstalledwithin36inchesofceiling
fansorsupplyregisters.
l
Inareaswheretemperatureiscolderthan40˚F(4.4˚C)orhotter
than100˚F(37.8˚C).
l
Ininsectinfestedareas.Insectscanclogtheopeningstothe
sensingchamber.
l
Lessthan12inches(305mm)awayfromfluorescentlights.
Electrical“noise”caninterferewiththesensor.
l
Prolongedexposuretocertainchemicalscanimpactthedetector’s
performance,pleaseinstallthisunitawayfromexposuretocleaning
agentsandotherhouseholdchemicals.
l
In“deadair”spaces.“Deadair”spacesmaypreventsmokefrom
reachingtheSmokeAlarm.
AvoidingDeadAirSpaces
“Deadair”spacesmaypreventsmokefromreachingtheSmokeAlarm.
Toavoiddeadairspaces,followtheinstallationrecommendations
below.
Onceilings,installSmokeAlarmsasclosetothecenteroftheceilingas
possible.Ifthisisnotpossible,installtheSmokeAlarmatleast4inches
(102mm)fromthewallorcorner.
Forwallmounting(ifallowedbybuildingcodes),thetopedgeofSmoke
Alarmsshouldbeplacedbetween4inches(102mm)and12inches(305
mm)fromthewall/ceilingline,belowtypical“deadair”spaces.
Onapeaked,gabled,orcathedralceiling,installthefirstSmokeAlarm
within3feet(0.9meters)ofthepeakoftheceiling,measured
horizontally.AdditionalSmokeAlarmsmayberequireddependingonthe
length,angle,etc.oftheceiling’sslope.RefertoNFPA72fordetailson
requirementsforslopedorpeakedceilings.
Foradditionalinformation,contactyourlocalAuthorityHaving
Jurastiction(AHJ).
02
Installation
HowToInstallThisSmoke/coAlarm
ThisSmoke/COAlarmisdesignedtobemountedonanystandardwiring
junctionboxuptoa4-inch(10cm)size,oneithertheceilingorwall(ifallowed
bylocalcodes).Read“"WhereToInstallThisAlarm"above”and“"WhereNot
ToInstallThisAlarm"above”intheRegulatoryGuidebeforeyoubegin
installation.MountthealarmflushtotheelectricalboxtoeliminateairNOTE:
leaksbetweentheceilingsurfaceandthemountingbracket.
Toolsyouwillneed:•Needle-nosepliersorutilityknife•Standardflathead
screwdriver•Wirestrippers.
DANGER!
ELECTRICALSHOCKHAZARD
TurnoffthepowertotheareawheretheAlarmisinstalledbefore
removingitfromthemountingbracket.Failuretoturnoffthepower
firstmayresultinseriouselectricalshock,injuryordeath.
FollowTheseInitialInstallationSteps
ThebasicinstallationofthisAlarmissimilarwhetheryouwanttoinstallone
Alarm,orinterconnectmorethanoneAlarm.Ifyouareinterconnectingmore
thanoneAlarm,youMUSTread“"SpecialRequirementsforInterconnected
Alarms"below”beforeyoubegininstallation.
NOTE:Installinaccordancewithinstallationinstructions,applicablecodes
andordinancesandinamanneracceptabletotheauthorityhaving
jurisdiction.CheckwithyourlocalFireDepartmentforcurrentrequirements
inyourarea.
IMPORTANT:
l
Neverconnectthehotorneutralwiresinthejunctionboxtotheorange
interconnectwire.NevercrosshotandneutralwiresbetweenAlarms.
l
Improperwiringofthepowerconnectororthewiringleadingtothe
powerconnectorwillcausedamagetotheAlarmandmayleadtoanon-
functioningAlarm.
l
MakesuretheAlarmisnotreceivingexcessivelynoisypower.Examples
ofnoisypowercouldbemajorappliancesonthesamecircuit,power
fromageneratororsolarpower,lightdimmeronthesamecircuitor
mountednearfluorescentlighting.Excessivelynoisypowermaycause
damagetoyourAlarm.
SC2-019-V0
1
3
4
56
2
OPTIONAL
ORANGE/RED/YELLOW
ORANGE
COPPER -
NOT USED
BLACK
BLACK
WHITE
WHITE
INTERCONNECT WIRE,
ONLY IF USED.
NOTES:
l
Ifusingthemodelswithreplaceablebatteries,installthem.Battery
back-upcannotworkuntilyouinstallthebatteryinthecorrectposition
(Match“+”to“+”and“-”to“-”).
l
Instepsix,activationisaonetimeuseonly.
STAND-ALONEALARMONLY:
l
IfyouareonlyinstallingoneAlarm,restorepowertothejunctionbox.
INTERCONNECTEDUNITSONLY:
l
IfyouareinterconnectingmultipleAlarms,repeatsteps1-6foreach
Alarmintheseries.Whenyouarefinished,restorepowertothejunction
box.
NOTES:
l
MakesuretheAlarmisreceivingACpower.Undernormaloperation,
theGreenpowerindicatorlightwillshinecontinuously.
l
TesteachSmokeAlarm.PressandholdtheTest/Silencebuttonuntil
theunitalarms.Whentestingaseriesofinterconnectedunitsyou
musttesteachunitindividually.Makesureallunitsalarmwheneach
oneistested.
DANGER!
Ifanyunitintheseriesdoesnotalarm,andrecheckTURNOFFPOWER
connections.Ifitdoesnotalarmwhenyourestorepower,replaceit
immediately.
SpecialRequirementsForInterconnected
Alarms
IMPORTANT:
l
Failuretomeetanyoftherequirementscoulddamagetheunitsand
causethemtomalfunction,removingyourprotection.
l
ACandAC/DCAlarmscanbeinterconnected.UnderACpower,allunits
willalarmwhenonesensessmokeorCO.Whenpowerisinterrupted,
onlytheAC/DCunitsintheserieswillcontinuetosendandreceive
signals.AConlypoweredAlarmswillnotoperate.
CompatibleInterconnectedUnits
Interconnectunitswithinasinglefamilyresidenceonly.Otherwiseall
householdswillexperienceunwantedalarmswhenyoutestanyunitinthe
series.Interconnectedunitswillonlyworkiftheyarewiredtocompatibleunits
andallrequirementsaremet.
ScantheQRCodetoviewalistofcompatibleinterconnected
units
InterconnectedunitsmustmeetALLofthefollowingrequirements:
l
Amaximumof18compatibleunitsmaybeinterconnected(Maximumof
12SmokeAlarms).
l
Thesamefuseorcircuitbreakermustpowerallinterconnectedunits.
l
Thetotallengthofwireinterconnectingtheunitsshouldbelessthan
1000feet(300meters).Thistypeofwireiscommonlyavailableat
HardwareandElectricalSupplystores.
l
AllwiringmustconformtoalllocalelectricalcodesandNFPA70(NEC).
RefertoNFPA72,NFPA101,and/oryourlocalbuildingcodeforfurther
connectionrequirements.
6
7
8
4
3
1
5
2
A
B
}
}
4
3
1
5
SC2-10-V0
A.Unswitched120VAC
60Hzsource
B.Toadditionalunits;Maximum=18total
(Maximum12SmokeAlarms)
1.Alarm
2.CeilingorWall
3.PowerConnector
4.WireNut
5.JunctionBox
6.NeutralWire(Wht)
7.InterconnectWire
(Orange)
8.HotWire(Blk)
LockingFeature(Optional)
Thelockingfeatureisdesignedtodiscourageunauthorizedaccesstothe
alarmsbatterycompartment.Itisnotnecessarytoactivatethelockinsingle-
familyhouseholdswhereunauthorizedbatteryorAlarmremovalisnota
concern.
ModelswithNon-ReplaceableBatteries:Thisalarmisshippedfromthe
factorywiththebatterydrawerlockedbecauseitfeaturesa10-yearbattery
backup.Undernormalconditionsyoushouldnothavetoreplacethebattery
forthelifeofthealarm.
ModelswithReplaceablebatteries:Ifyouneedtoreplacethebatteryfollow
"RemovingTheBatteryCompartmentLock"below.Re-lockBattery
Compartmentifdesired.
SC2-011-V0
Locking Pin
Toolsyouwill
need:•Needle-
nosepliersor
utilityknife•
StandardFlathead
screwdriver.
Thelocking
featureuses
lockingpins,
moldedintothe
mountingbracket.
Usingneedlenosepliersorautilityknife,removethepin.
RemovingTheBatteryCompartmentLock
IMPORTANT:OncetheAlarmisinstalled,youmustdisconnectitfromtheAC
powerbeforeunlockingthebatterycompartment.
DANGER!
ELECTRICALSHOCKHAZARD
TurnoffthepowertotheareawheretheAlarmisinstalledbefore
removingitfromthemountingbracket.Failuretoturnoffthepower
firstmayresultinseriouselectricalshock,injuryordeath.
SC2-014-V0
1.
RemovetheAlarmfrom
themountingbracket.
2.
Disconnectthepower
connectorbygentlyprying
itawayfromthebackof
theAlarm.
3.
Scoretheareaaroundthe
lockingpintobreakthe
seal.Insertaflathead
screwdriverunderthe
headofthelockingpinor
useaneedlenosepliersto
gentlypryitoutofthe
batterycompartmentlock.
(Ifyouplantore-lockthebatterycompartment,savethelockingpin.)
4.
Tore-lockthebatterycompartment,closethebatterydoorandreinsert
thelockingpininthelock.
5.
ReconnectthepowerconnectortothebackoftheAlarm,reattachthe
Alarmtothemountingbracket,andrestorethepower.
NOTE:Whenreplacingthebattery,alwaystesttheAlarmbeforere-locking
thebatterycompartment.
ToLockTheBatteryCompartment
NOTE:Donotlockthebatterycompartmentuntilyouhaveactivatedthe
batteryandtestedthebatteryback-up.
1.
Usingneedle-nosepliersorautilityknife,detachonelockingpinfrom
themountingbracket.
SC2-009-V0
2.
Pushthelockingpinthroughtheblackdotonthelabelonthebackofthe
Alarm.
SC2-012-V1
03
Operation
HowYourSmoke&Smoke/COAlarmWorks
SC2-006-V0
1.
Test/SilenceButton:Press
andholdtoactivatetest,
ortosilencealarm.
2.
SMOKE&COLED
3.
BATTERY*,POWER,
andREPLACEDEVICELED
4.
BatteryCompartment
5.
(Behindthecover)Alarm
Horn:85dBaudiblealarm
fortest,alarm,andunit
malfunctionwarning.
*BATTERYLEDonlyexistson
modelswithreplaceable
batteries.
NOTE:Smokedetectorsare
nottobeusedwithdetector
guardsunlessthecombinationhasbeenevaluatedbytheListingagency
andapprovedforuse.
WhatYouWillSee&HearWithThisAlarm
Modelswith
ReplaceableBatteries
Modelswith10-year
Non-ReplaceableBattery
SC2-023-V0
WhatYouWillHearWhatyouwillSeeModeofOperation
None
ConstantGreen
(AC);GreenFlash
(DC)
NormalOperation
3beeps,pause,3
beeps
FlashesRedSmokeAlarmTest
4beeps,pause,4
beeps
FlashesRedCOAlarmTest
Soft,decending6
tonebeep
FlashesYellowevery
2secondsuntilthe
truelow-battery
cycleoccursorthe
unitisreplaced
LowBattery,
Pre-Warning
1chirpeveryminute
1yellowflashin
syncwiththehorn
pattern;followedby
1yellowflashevery
6seconds
LoworMissing
Battery
3chirpsevery
minute
3yellowflashesin
syncwiththehorn
pattern;followedby
3yellowflashes
every6seconds
IfAlarmisNotOper-
atingProperly
(MALFUNCTION
SIGNAL)
Soft,decending6
tonebeep
5yellowflashes
every6seconds
untilthetrueEndof
Lifecycleoccursor
theunitisreplaced
EndofLife,
Pre-Warning
5chirpsevery
minute
5yellowflashesin
syncwiththehorn
pattern;followedby
5yellowflashes
every6seconds
Alarmhasreachedits
EndofLife
4beeps,pause,4
beeps*
FlashesRedinsync
withthehornpat-
tern.AfterAlarm:
FlashesRedOnfor4
seconds/Offfor4
seconds.COalarm
latchisnow
engaged.
AlarmLevelsofCO
areDetected
3beeps,pause,3
beeps
FlashesRedinsync
withthehornpat-
tern.AfterAlarm:
FlashesRedOnfor2
seconds/Offfor2
seconds.Smoke
alarmlatchisnow
engaged.
SmokeisDetected
NoneFlashesRed
SmokeAlarmis
Silenced
NoneFlashesRedCOAlarmisSilenced
NoneFlashesYellowAlarmneedscleaning
*IfunitgoesintoCOAlarm,theregular4beepsbriefpausecyclewill
repeatfor15minutes.After15minutesthepausewillincreasetoone
minute.
IfYourSmoke&Smoke/COAlarmSounds
WhatToDoFirst-IdentifyTheTypeOfAlarmSignal
TypeofAlarmWhatYouWillSee&Hear
CarbonMonoxide(CO)
Horn:4beeps,pause,4beeps,
pause;FlashesRedAlarmLED:
Smoke
Horn:3beeps,pause,3beeps,
pause;FlashesRedAlarmLED:
IfTheCOAlarmSounds(4Beeps):
!
WARNING!
ACTUATIONOFTHISDEVICEINDICATESTHEPRESENCEOFCARBON
MONOXIDE(CO)WHICHCANKILLYOU.IFALARMSOUNDS4BEEPS:
1.
IMMEDIATELYMOVETOFRESHAIR-OUTDOORSORBYANOPEN
DOORORWINDOW.CHECKTHATALLPERSONSARE
ACCOUNTEDFOR.DONOTRE-ENTERTHEPREMISESORMOVE
AWAYFROMTHEOPENDOOR/WINDOWUNTILTHEEMERGENCY
SERVICESRESPONDERSHAVEARRIVED,THEPREMISESHAVE
BEENAIREDOUT,ANDYOURALARMRETURNSTOITSNORMAL
CONDITION.
2.
CALLYOUREMERGENCYLOCALSERVICE,FIREDEPARTMENTOR
911.Writedownthenumberofyourlocalemergencyservice
here:_____________________________________________
3.
PresstheTest/Silencebutton.
4.
Afterfollowingsteps1-3,ifyourCOAlarmreactivateswithina24-
hourperiod,repeatsteps1-3andcallaqualifiedappliance
techniciantoinvestigateforsourcesofCOfromfuel-burning
equipmentandappliances,andinspectforproperoperationofthis
equipment.Ifproblemsareidentifiedduringthisinspectionhave
theequipmentservicedimmediately.Noteanycombustion
equipmentnotinspectedbythetechnician,andconsultthe
manufacturers’instructions,orcontactthemanufacturersdirectly,
formoreinformationaboutCOsafetyandthisequipment.Make
surethatmotorvehiclesarenot,andhavenot,beenoperatingin
anattachedgarageoradjacenttotheresidence.Writedownthe
numberofaqualifiedappliancetechnicianhere:_________________
_______________________
IfTheSmokeAlarmSounds(3Beeps):
Ifyouhearthealarmhornsound3beeps,pause,3beeps,pauseandthe
REDSMOKElightisflashing,smokehasbeendetected.Evacuateeveryone
fromthebuilding.
RespondingToAnAlarm
!
WARNING!
l
IftheunitAlarmsandyouarenottestingtheunit,itiswarningyou
ofapotentiallydangeroussituationthatrequiresyourimmediate
attention.NEVERignoreanyAlarm.IgnoringtheAlarmmayresult
ininjuryordeath.
l
WhenaninterconnectedsystemofACpoweredunitsisinalarm,
thealarmindicatorlightontheunit(s)thatinitiatedthealarmwill
blinkrapidly.ItwillremainOFFonanyremainingunits.
l
Iftheunitalarms,geteveryoneoutofthedwellingimmediately.
l
Iftheunitalarmsandyouarecertainthatthesourceofsmokeis
notafire—cookingsmokeoranextremelydustyfurnace,for
example—openanearbywindowordoorandfanthesmokeaway
fromtheunit.UsetheSilenceFeaturetosilencetheAlarm.This
willsilencethealarm,andoncethesmokeclearstheunitwillreset
itselfautomatically.
WhatToDoInCaseOfAFire
l
Don’tpanic;staycalm.Followyourfamilyescapeplan.
l
Getoutofthehouseasquicklyaspossible.
l
Feeldoorswiththebackofyourhandbeforeopeningthem.Ifadooris
cool,openitslowly.Don’topenahotdoor.Keepdoorsandwindows
closed,unlessyoumustescapethroughthem.
l
Coveryournoseandmouthwithacloth(preferablydamp).Takeshort,
shallowbreaths.
l
Meetatyourplannedmeetingplaceoutsideyourhome,anddoahead
counttomakesureeverybodygotoutsafely.
l
CalltheFireDepartmentassoonaspossiblefromoutside.Giveyour
address,thenyourname.
l
Nevergobackinsideaburningbuildingforanyreason.
l
ContactyourFireDepartmentforideasonmakingyourhomesafer.
NOTE:Alarmshavevariouslimitations.See"GeneralLimitationsof
Smoke/COAlarms"onthenextpagefordetails.
“SmartInterconnect”Feature
Thisalarmincludes“SmartInterconnect”whichenablesthealarmtobe
interconnectedwithotherFirstAlert&BRKSmoke,Heat,and“Smart
Interconnect”COAlarms.Whensmokeisdetected,allalarmswillsoundthe
smokehornpattern.WhenCOisdetected,“SmartInterconnect”alarmswill
soundtheCOhornpattern.Alarmsthatdonothavethe“SmartInterconnect”
FeaturewillremainsilentduringaCOalarm.
InterconnectedAlarms
Interconnectedunitscanprovideearlierwarningoffirethanstand-aloneunits,
especiallyifafirestartsinaremoteareaofthedwelling.Ifanyunitinthe
seriessensessmoke,allinterconnectedunitswillalarm.Todeterminewhich
unitinitiatedanalarm,seetable:
DuringanAlarm:
OnInitiatingAlarms:RedLED(s)flashes(flash)rapidly
OnAllotheralarms:RedLEDisOff
AfteranAlarm(Latching):
OnInitiatingAlarms:RedLED(s)onfor2-seconds/Offfor2-
seconds
OnAllotheralarms:GreenLED(s)On,RedLED(s)Off
UsingTheSilenceFeatures
!
WARNING!
Neverunplugthealarmorremovethebatteriestoquietanunwanted
Alarm.RemovingthebatteriesdisablestheAlarmandremovesyour
protection.Insteadopenawindoworfanthesmokeawayfromtheunit.
TheAlarmwillresetautomatically.
TheSilenceFeatureisintendedtotemporarilysilencethehornwhileyou
identifyandcorrecttheproblem.DonotusetheSilenceFeatureinemergency
situations.ItwillnotcorrectaCOproblemorextinguishafire.TheSilence
FeaturecantemporarilyquietanunwantedAlarmforseveralminutes.You
cansilencethisAlarmbypressingtheTest/SilencebuttonontheAlarmcover
untilitchirps,thenrelease.AftertheTest/Silencebuttonisreleased,theRed
LEDblinksduringthesilencemode.ActivatetheAlarmtest,resetorsilence
functionbyuseofafingerorthumb.Useofanyotherinstrumentisstrictly
prohibited.
WhentheSmoke
AlarmisSilenced
WhentheCOAlarmis
Silenced
Soft-tone
Pre-Warning
TheSmokeAlarmwill
remainsilentforupto
10minutes,thenreturn
tonormaloperation.
Ifthesmokehasnot
cleared–orcontinues
toincrease–thedevice
willgobackinto
Alarm.
TheCOAlarmwill
remainsilentforupto5
minutes.
After5minutes,ifCO
levelsremainpoten-
tiallydangerousthe
hornwillstartsounding
again.
Notifiestheend
user5-7days
priortothe
actuallow-bat-
terywarning.
SilencingTheLowBatteryWarning
ThisSilenceFeaturecantemporarilyquietthelowbatterywarning“chirp”for
upto8hoursifACpowerispresent.PresstheTest/Silencebuttononthe
Alarmcoveruntilyouheartheacknowledge“chirp”.
Oncethelowbatterywarning“chirp”silencefeatureisactivated,theunit
continuestoflashthegreenlightonceaminutefor8hours.After8hours,the
lowbattery“chirp”willresume.TheAlarmwillcontinuetooperateaslongas
ACpowerissupplied.However,,toreplacethebatteriesassoonaspossible
maintainprotectionineventofapoweroutage.
TosilenceAlarmsinaninterconnectedseries:
TosilenceaninterconnectedseriesofAlarms,youmustpressthe
Test/Silencebuttonontheinitiatingalarm(Theunitwiththeflashingredlight;
theredlightwillbeoffonallotherAlarms.).IfyoupresstheTest/Silenceon
anyotherAlarm,itwillonlysilencethatunit,notthewholeinterconnected
series.
SilencingTheEndOfLifeSignal
Thisalarmisequippedwitha10-yearendoflifeandstartswhenthepulltab
isremovedfromthebatterycompartment.
ThisSilenceFeaturecantemporarilyquiettheEndofLifewarning“chirp”for
upto2days.YoucansilencetheEndofLifewarning“chirp”bypressingthe
Test/Silencebutton.Thehornwillchirp,acknowledgingthattheEndofLife
SilenceFeaturehasbeenactivated.
Afterapproximately2days,theEndofLife“chirp”willresume.
LatchingFeatures
AlarmLatchisactivatedafteranAlarmisexposedtoalarmlevelsofsmokeor
carbonmonoxide.ThisfeaturewillonlyworkwithACpower.Aftersmokeor
COlevelsdropbelowalarmlevels,the“”RedLEDwillbegintoflashAlarm
onceeveryfewseconds.Itwillcontinuetoflashor“latch”untilyouclearitby
testingthealarm.
Thisfeaturehelpsemergencyresponders,investigators,orservice
techniciansidentifywhichunit(s)inyourhomewereexposedtoalarmlevels
ofsmokeorcarbonmonoxide.Thiscanhelpinvestigatorspinpointthesource
ofsmokeorCO.
InterconnectedAlarms.LatchingAlarmIndicatorshowswhichAlarm(s)inthe
serieswereexposedtoalarmlevelsofsmokeorcarbonmonoxide.
TheLatchingAlarmIndicatorstaysONuntilyouclearit,soitcanalertyouto
analarmthatoccurredwhileyouwereawayfromhome.
PermanentlyDeactivatingTheAlarm(Non-
ReplaceableBatteryModels)
NOTE:AlarmisSealed.Thepowercellisnotreplaceable.Onceitreaches
theendofitsservicelife,orafter10years-whichevercomesfirst-you
mustinstallanewSmoke/COalarm.
After10yearsorafterthe"lowpowerwarning"sounds(whichevercomes
first):
1.
Pushfirmlythroughthebreakawaydeactivationtab.
2.
Liftthetab.
SC-024-V1
12
Onceyoudeactivatethisunit,itwillnotdetectsmokeorcarbonmonoxideand
willnotalarm.ItcanNOTbereactivated.Youmustinstallanewunitto
continueyourprotection.Alarmwillresistmountingtothebracketafter
deactivation.
04
Testing&Maintenance
WeeklyTesting
!
WARNING!
l
Itisimportanttotestthisuniteveryweektomakesureitisworking
properly.Usingthetestbuttonistherecommendedwaytotestthis
Smoke/COAlarm.
l
NEVERuseanopenflameofanykindtotestthisunit.Youmight
accidentallydamageorsetfiretotheunitortoyourhome.Thebuilt-in
testswitchaccuratelyteststheunit’soperationasrequiredby
UnderwritersLaboratories,Inc.(UL).NEVERusevehicleexhaust!
Exhaustmaycausepermanentdamageandvoidsyourwarranty.
l
IftheAlarmeverfailstotestproperly,replaceitimmediately.Products
underwarrantymaybereturnedtothemanufacturerforreplacement.
See"LimitedWarranty"onthenextpage
SC2-018-V0
Totestthisalarmpressand
releasetheTest/Silencebutton.
Thealarmwillchirp.Toexittest
moderepeatthesesteps.
Duringtesting,youwillseeand
hearthefollowingsequence:
l
Thewillsound3Horn
beeps,pause,3beeps.
TheflashesAlarmLED
Redinsyncwiththehorn
pattern.
l
Nextthewillsound4Horn
beeps,pause,4beeps.
TheflashesAlarmLED
Redinsyncwiththehorn
pattern.
Iftheunitdoesnotalarm,makesurethebatteriesarecorrectlyinstalled,
andtestagain.Iftheunitstilldoesnotalarm,replaceitimmediately.
RegularMaintenance
Thisunithasbeendesignedtobeasmaintenance-freeaspossible,butthere
areafewsimplethingsyoumustdotokeepitworkingproperly:
l
Testitatleastonceaweek.
l
CleantheAlarmatleastonceamonth;gentlyvacuumtheoutsideofthe
Alarmusingyourhouseholdvacuum’ssoftbrushattachment.
o
Neverusewater,cleanersorsolventssincetheymaydamagethe
unit.
o
IftheAlarmbecomescontaminatedbyexcessivedirt,dustand/or
grime,andcannotbecleanedtoavoidunwantedalarms,replace
theunitimmediately.
NOTE:Topreventfalseornuisancealarms,theaccommodating
spacesaretobewellventilatedwhenhouseholdcleaning
suppliesorsimilarcontaminantsareused.
WhenToChangeTheBatteryBackup(replaceableBattery
ModelsOnly)
Whenthebatteryback-upbecomesweak,theAlarmwill“chirp”aboutoncea
minute(thelowbatterywarning).Thiswarningshouldlast7days,butyou
shouldreplacethebatteryimmediatelytocontinueyourprotection.TheLow
BatteryLatchfeaturewillbeengaged.LEDFlashes1chirpperminute;1
yellowflashinsyncwiththehornpattern;followedby1yellowflashevery6
seconds.(LowBatteryLatchisengaged.)
ChoosingAReplacementBattery
YourAlarmrequirestwo“AA”batteries:KendalLR6,EnergizerE91,orDuracell
MN1500.Thesebatteriesareavailableatmanylocalretailstores.
!
WARNING!
l
AlwaysusetheexactbatteriesspecifiedbythisManual.DONOTuse
rechargeablebatteries.Installbatteriescorrectlywithregardtopolarity
(+and-).
l
Pleasedisposeoforrecycleusedbatteriesproperly,followinganylocal
regulations.Consultyourlocalwastemanagementauthorityor
recyclingorganizationtofindanelectronicsrecyclingfacilityinyour
area.DONOTDISPOSEOFBATTERIESINFIRE.BATTERIESMAY
EXPLODEORLEAK.
l
Keepbatteryoutofreachofchildren.Intheeventabatteryis
swallowed,immediatelycontactyourpoisoncontrolcenter,your
physician,ortheNationalBatteryIngestionhotlineat202-625-3333as
seriousinjurymayoccur.
NOTE:ActualbatteryservicelifedependsontheSmoke/COAlarmandthe
environmentinwhichitisinstalled.Constantexposuretohighorlow
humiditycanreducebatterylife.Allthebatteriesspecifiedaboveare
acceptablereplacementbatteriesforthisunit.Regardlessofthe
manufacturer’ssuggestedbatterylife,youMUSTreplacethebattery
immediatelyoncetheunitstarts“chirping”(the“lowbatterywarning”).
Toreplacethebatteries(withoutremovingAlarmfromtheceilingorwall):
1.
Openthebatterycompartmentbyslidingtheswitchtotheleft.
2.
PresstabsAandBasshowninthediagramandremoveeachbattery.
3.
Insertthenewbatteries,makingsuretheysnapcompletelyintothe
batterycompartment.Matchtheterminalsontheendsofthebatteries
withtheterminalsontheunit.
4.
Closethebatterycompartment;youwillhearaclickensuringitisclosed
alltheway,andthentesttheunitbypressingtheTest/Silencebutton.
1
2
SC2-0013-V1
TroubleshootingGuide
IFTHEALARM...PROBLEM...YOUSHOULD...
Soft,descendent6
tonebeep;Yellow
blinkinglight
Pre-warning
alertforlowbat-
tery.
EndofLife,Pre-Warning;
InstalltwonewAAbat-
teries*.
1chirpperminute;
1yellowflashin
syncwiththehorn
pattern;followed
by1yellowflash
every6seconds.
(LowBatteryLatch
isengaged.)
Lowbattery
warning.
InstalltwonewAAbat-
teries*.
Hornsounds3
“chirps”per
minute;3yellow
flashesinsync
withthehornpat-
tern;followedby3
yellowflashes
every6seconds
MALFUNCTION
SIGNAL.Device
isnotworking
properly,and
needstobe
replaced.
Ifunitisunderwarranty,con-
tactConsumerSupportto
processawarrantyreplace-
ment.
CARBONMONOXIDEALARMONLY
COAlarmgoes
backintoAlarm5
minutesafteryou
silenceit.
COlevelsindic-
ateapotentially
dangeroussitu-
ation.
IFYOUAREFEELING
SYMPTOMSOFCO
POISONING,EVACUATEyour
homeandcall911ortheFire
Department.Referto“IfThe
COAlarmSounds”for
details.
COAlarmsounds
frequentlyeven
thoughnohigh
levelsofCOare
revealedinan
investigation.
TheCOAlarm
maybeimprop-
erlylocated.
Referto“Where
toInstallThis
Alarm”for
details.
RelocateyourAlarm.Iffre-
quentAlarmscontinue,have
homerecheckedforpotential
COproblems.Youmaybe
experiencinganintermittent
COproblem.
SMOKEALARMONLY
IFTHEALARM...PROBLEM...YOUSHOULD...
SmokeAlarm
soundswhenno
smokeisvisible.
Unwanted
Alarmmaybe
causedbynon-
emergency
sourcelike
cookingsmoke.
SilenceAlarmusingTest/Si-
lencebutton;cleanthe
Alarm’scoverwithasoft,
cleancloth.Iffrequent
unwantedAlarmscontinue,
relocateyourAlarm.Alarm
maybetooclosetoakit-
chen,cookingappliance,or
steamybathroom.
*Foralistofacceptablereplacementbatteries,see""Regular
Maintenance"above."
Ifyouhavequestionsthatcannotbeansweredbyreadingthis
manual,calltheConsumerSupportTeamat1-800-323-9005.
05
Regulatory
AgencyPlacementRecommendations
Standards:UnderwritersLaboratoriesInc.SingleandMultipleStationSmoke
Alarms217.
NFPA72CHAPTER29
“FORYOURINFORMATION,THENATIONALFIREALARMANDSIGNALING
CODE,NFPA72,READSASFOLLOWS:”
29.5.1*RequiredDetection.29.5.1.1*Whererequiredbyothergoverninglaws,
codes,orstandardsforaspecifictypeofoccupancy,approvedsingleand
multiple-stationSmokeAlarmsshallbeinstalledasfollows:
1.
*Inallsleepingroomsandguestrooms
2.
*Outsideofeachseparatedwellingunitsleepingarea,within21ft(6.4
m)ofanydoortoasleepingroom,withthedistancemeasuredalonga
pathoftravel
3.
Oneverylevelofadwellingunit,includingbasements
4.
Oneverylevelofaresidentialboardandcareoccupancy(smallfacility),
includingbasementsandexcludingcrawlspacesandunfinishedattics
5.
*Inlivingarea(s)ofaguestsuite
6.
Inthelivingarea(s)ofaresidentialboardandcareoccupancy(small
facility)
(ReprintedwithpermissionfromNFPA72
®
,NationalFireAlarmandSignaling
CodeCopyright©2012NationalFireProtectionAssociation,Quincy,MA
02269.Thisreprintedmaterialisnotthecompleteandofficialpositionofthe
NationalFireProtectionAssociation,onthereferencedsubjectwhichis
representedonlybythestandardinitsentirety).
(NationalFireAlarmandSignalingCode
®
andNFPA72
®
areregistered
trademarksoftheNationalFireProtectionAssociation,Inc.,Quincy,MA
02269).
CaliforniaStateFireMarshal(CSFM)
Earlywarningdetectionisbestachievedbytheinstallationoffiredetection
equipmentinallroomsandareasofthehouseholdasfollows:ASmokeAlarm
installedineachseparatesleepingarea(inthevicinity,butoutsidebedrooms),
andHeatorSmokeAlarmsinthelivingrooms,diningrooms,bedrooms,
kitchens,hallways,finishedattics,furnacerooms,closets,utilityandstorage
rooms,basements,andattachedgarages.
WhatYouNeedToKnowAboutCO
!
WARNING!
CARBONMONOXIDE(CO)ISA
COLORLESS,ODORLESS,
POISONOUSGAS.YOUCAN'T
TASTE,SEE,ORSMELLCO,BUTIT
CANKILLINJUSTMINUTES.THIS
ALARMWILLSOUNDINA4-BEEP
PATTERNIFLIFETHREATENING
LEVELSOFCOAREDETECTED.IF
THEALARMSOUNDS:
1)Immediatelyevacuatealloccu-
pantsfromthespaceandgoout-
doorstofreshair.
2)Callemergencyresponders(911
orfiredepartment)forhelp;notify
thebuildingorvehicleowner,as
necessary.
WhatIsCO?
COisaninvisible,odorless,tastelessgasproducedwhenfossilfuelsdo
notburncompletely,orareexposedtoheat(usuallyfire).Electrical
appliancestypicallydonotproduceCO.
CommonappliancesareoftensourcesofCO.Iftheyarenotproperly
maintained,areimproperlyventilated,ormalfunction,COlevelscanrise
quickly.
SymptomsOfCOPoisoning
THEFOLLOWINGSYMPTOMSMIGHTBERELATEDTOCARBON
MONOXIDEPOISONINGANDSHOULDBEDISCUSSEDWITHALL
MEMBERSOFTHEHOUSEHOLD:
MILDEXPOSURE:HEADACHES,FATIGUE,DROWSINESS,SHORTNESSOF
BREATH,“FLU”-LIKESYMPTOMS(WITHOUTFEVER),ANDIMPAIRED
MOTORFUNCTIONS(LIKEDIFFICULTYWALKINGORPROBLEMSWITH
BALANCE);
MEDIUMEXPOSURE:DIZZINESS,NAUSEAANDVOMITING,CHESTPAIN,
POORVISION,DIFFICULTYTHINKING;
EXTREMEEXPOSURE:LOSSOFCONSCIOUSNESS,CONVULSIONS,
COMA,ANDDEATH.
WHENFLU-LIKESYMPTOMSWITHFEVERAREEXPERIENCED,ENSURE
THATTHEPOSSIBILITYOFPOISONINGISNOTAUTOMATICALLYRULED
OUT.MANYCASESOFREPORTEDCARBONMONOXIDEPOISONING
INDICATETHATWHILEVICTIMSAREAWARETHEYARENOTWELL,
THEYBECOMESODISORIENTEDTHEYAREUNABLETOSAVE
THEMSELVESBYEITHEREXITINGTHEBUILDINGORCALLINGFOR
ASSISTANCE.
!
WARNING!
ThisCOAlarmmeasuresexposuretoCOovertime.ItalarmsifCO
levelsareextremelyhighinashortperiodoftime,orifCOlevels
reachacertainminimumoveralongperiodoftime.TheCOAlarm
generallysoundsanalarmbeforetheonsetofsymptomsin
average,healthyadults.Whyisthisimportant?Becauseyouneed
tobewarnedofapotentialCOproblemwhileyoucanstillreactin
time.IfyouexperienceevenmildsymptomsofCOpoisoning,
consultyourdoctorimmediatelyorcall911togethelp!
FindingTheSourceOfCOAfterAnAlarm
Carbonmonoxideisanodorless,invisiblegas,whichoftenmakesit
difficulttolocatethesourceofCOafteranalarm.Theseareafewofthe
factorsthatcanmakeitdifficulttolocatesourcesofCO:
l
Housewellventilatedbeforetheinvestigatorarrives.
l
Problemcausedby“backdrafting.”
l
TransientCOproblemcausedbyspecialcircumstances.
BecauseCOmaydissipatebythetimeaninvestigatorarrives,itmaybe
difficulttolocatethesourceofCO.Resideoshallnotbeobligatedtopay
foranycarbonmonoxideinvestigationorservicecall.
PotentialSourcesOfCOInTheHome
Fuel-burningapplianceslike:portableheater,gasorwoodburning
fireplace,gaskitchenrangeorcooktop,gasclothesdryer.
Damagedorinsufficientventing:corrodedordisconnectedwaterheater
ventpipe,leakingchimneypipeorflue,orcrackedheatexchanger,
blockedorcloggedchimneyopening.
Improperuseofappliance/device:operatingabarbecuegrillorvehicle
inanenclosedarea(likeagarageorscreenedporch).
TransientCOProblems:“transient”oron-again-off-againCOproblems
canbecausedbyoutdoorconditionsandotherspecialcircumstances.
ThefollowingconditionscanresultintransientCOsituations:
1.
Excessivespillageorreverseventingoffuelappliancescausedby
outdoorconditionssuchas:
l
Winddirectionand/orvelocity,includinghigh,gustywinds.
Heavyairintheventpipes(cold/humidairwithextended
periodsbetweencycles).
l
Negativepressuredifferentialresultingfromtheuseof
exhaustfans.
l
Severalappliancesrunningatthesametimecompetingfor
limitedfreshair.
l
Ventpipeconnectionsvibratingloosefromclothesdryers,
furnaces,orwaterheaters.
l
Obstructionsinorunconventionalventpipedesignswhichcan
amplifytheabovesituations.
2.
Extendedoperationofunventedfuelburningdevices(range,oven,
fireplace).
3.
Temperatureinversions,whichcantrapexhaustclosetothe
ground.
4.
Caridlinginanopenorclosedattachedgarage,ornearahome.
Theseconditionsaredangerousbecausetheycantrapexhaustinyour
home.Sincetheseconditionscancomeandgo,theyarealsohardto
recreateduringaCOinvestigation.
HowCanIProtectMyFamilyFromCOPoisoning?
ACOAlarmisanexcellentmeansofprotection.Itmonitorstheairand
soundsaloudalarmbeforeCarbonMonoxidelevelsbecomethreatening
foraverage,healthyadults.
ACOAlarmisnotasubstituteforpropermaintenanceofhome
appliances.
TohelppreventCOproblemsandreducetheriskofCOpoisoning:
l
Cleanchimneysandfluesyearly.Keepthemfreeofdebris,leaves,
andnestsforproperairflow.Also,haveaprofessionalcheckfor
rustandcorrosion,cracks,orseparations.
l
Testandmaintainallfuel-burningequipmentannually.Manylocal
gasoroilcompaniesandHVACcompaniesofferappliance
inspectionsforanominalfee.
l
Checkthehouseorgarageontheothersideofsharedwall.
l
Keepwindowsanddoorsopenslightly.IfyoususpectthatCOis
escapingintoyourhome,openawindoworadoor.Opening
windowsanddoorscansignificantlydecreaseCOlevels.
Inaddition,familiarizeyourselfwithallenclosedmaterials.Readthe
manual(s)initsentirety,andmakesureyouunderstandwhattodoif
yourCOAlarmsounds.
RegulatoryInformationForCOAlarms
WhatLevelsOfCOCauseAnAlarm?
UnderwritersLaboratoriesInc.StandardUL2034requiresresidentialCO
AlarmstosoundwhenexposedtolevelsofCOandexposuretimesas
describedbelow.Theyaremeasuredinpartspermillion(ppm)ofCO
overtime(inminutes).
UL2034RequiredAlarmPoints*:
l
IftheAlarmisexposedto400ppmofCO,ITMUSTALARM
BETWEEN4and15MINUTES.
l
IftheAlarmisexposedto150ppmofCO,ITMUSTALARM
BETWEEN10and50MINUTES.
l
IftheAlarmisexposedto70ppmifCO,ITMUSTALARMBETWEEN
60and240MINUTES.
*Approximately10%COHbexposureatlevelsof10%to95%Relative
Humidity(RH).
TheunitisdesignednottoAlarmwhenexposedtoaconstantlevelof30
ppmfor30days.
!
WARNING!
COAlarmsaredesignedtoAlarmbeforethereisanimmediatelife
threat.SinceyoucannotseeorsmellCO,neverassumeit’snot
present.
l
Anexposureto100ppmofCOfor20minutesmaynotaffect
average,healthyadults,butafter4hoursthesamelevelmay
causeheadaches.
l
Anexposureto400ppmofCOmaycauseheadachesin
average,healthyadultsafter35minutes,butcancausedeath
after2hours.
Standards:UnderwritersLaboratoriesInc.SingleandMultipleStation
CarbonMonoxideAlarmsUL2034.
AccordingtoUnderwritersLaboratoriesInc.UL2034,Section1-1.2:
“CarbonmonoxideAlarmscoveredbytheserequirementsareintendedto
respondtothepresenceofcarbonmonoxidefromsourcessuchas,but
notlimitedto,exhaustfrominternal-combustionengines,abnormal
operationoffuel-firedappliances,andfireplaces.COAlarmsareintended
toAlarmatcarbonmonoxidelevelsbelowthosethatcouldcausealoss
ofabilitytoreacttothedangersofcarbonmonoxideexposure.”ThisCO
AlarmmonitorstheairattheAlarm,andisdesignedtoAlarmbeforeCO
levelsbecomelifethreatening.Thisallowsyouprecioustimetoleavethe
houseandcorrecttheproblem.ThisisonlypossibleifAlarmsare
located,installed,andmaintainedasdescribedinthismanual.
GasDetectionatTypicalTemperatureandHumidityRanges:TheCO
AlarmisnotformulatedtodetectCOlevelsbelow30ppmtypically.UL
testedforfalseAlarmresistancetoMethane(500ppm),Butane(300
ppm),Heptane(500ppm),EthylAcetate(200ppm),IsopropylAlcohol
(200ppm)andCarbonDioxide(5000ppm).Valuesmeasuregasand
vaporconcentrationsinpartspermillion.
SpecialComplianceConsiderations
ThisSmokeAlarmissuitableforuseinapartments,condominiums,
townhouses,hospitals,daycarefacilities,healthcarefacilities,boarding
houses,grouphomesanddormitoriesprovidedaprimaryfiredetection
systemalreadyexiststomeetfiredetectionrequirementsincommon
areaslikelobbies,hallways,orporches.UsingthisSmokeAlarmin
commonareasmaynotprovidesufficientwarningtoallresidentsor
meetlocalfireprotectionordinances/regulations.
ThisSmokeAlarmaloneisnotasuitablesubstituteforcompletefire
detectionsystemsinplaceshousingmanypeople—likeapartment
buildings,condominiums,hotels,motels,dormitories,hospitals,health
carefacilities,nursinghomes,daycarefacilities,orgrouphomesofany
kind.Itisnotasuitablesubstituteforcompletefiredetectionsystemsin
warehouses,industrialfacilities,commercialbuildings,andspecial-
purposenon-residentialbuildingswhichrequirespecialfiredetectionand
Alarmsystems.Dependingonthebuildingcodesinyourarea,thisSmoke
Alarmmaybeusedtoprovideadditionalprotectioninthesefacilities.
Innewconstruction,mostbuildingcodesrequiretheuseofACorAC/DC
poweredSmokeAlarmsonly.Inexistingconstruction,AC,AC/DC,orDC
poweredSmokeAlarmscanbeusedasspecifiedbylocalbuildingcodes.
THISEQUIPMENTSHOULDBEINSTALLEDINACCORDANCEWITHTHE
NATIONALFIREPROTECTIONASSOCIATION’SSTANDARD72(National
FireProtectionAssociation,BatterymarchPark,Quincy,MA02269).Refer
toNFPA101(LifeSafetyCode),localbuildingcodes,orconsultyourFire
Departmentfordetailedfireprotectionrequirementsinbuildingsnot
definedas“households”.
FCCCompliance
Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfora
ClassBdigitaldevice,pursuanttoPart15oftheFCCrules.Theselimits
aredesignedtoprovidereasonableprotectionagainstharmful
interferenceinaresidentialinstallation.Thisequipmentgenerates,uses
andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin
accordancewiththeinstructions,maycauseharmfulinterferenceto
radiocommunications.
However,thereisnoguaranteethattheinterferencewillnotoccurina
particularinstallation.Ifthisequipmentdoescauseharmfulinterference
toradioortelevisionreception,whichcanbedeterminedbyturningthe
equipmentoffandon,theuserisencouragedtotrytocorrectthe
interferencebyoneormoreofthefollowingmeasures:
l
Reorientorrelocatethereceivingantenna.
l
Increasetheseparationbetweentheequipmentandreceiver.
l
Connecttheequipmentintoanoutletonacircuitdifferentfromthat
ofthereceiver.
l
ConsultthedealeroranexperiencedradioorTVtechnicianforhelp.
!
WARNING!
Changesormodificationstotheproduct,notexpresslyapprovedby
FirstAlert,couldvoidtheuser’sauthoritytooperatetheequipment.
ResponsibleParty/IssuerofSupplier’sDeclarationofConformity:Resideo
Technologies,Inc.,16100N71stStreet,Scottsdale,AZ85254,Ph:480-573-
5340
ThisClassBdigitalapparatuscomplieswithCanadianICES-003.
GeneralLimitationsOfSmoke/COAlarms
!
WARNING!
THISPRODUCTISINTENDEDFORUSEINORDINARYINDOOR
RESIDENTIALAREAS.ITISNOTDESIGNEDTOMEASURE
COMPLIANCEWITHCOMMERCIALANDINDUSTRIALSTANDARDS.
ITISNOTDESIGNEDTOMEASURECOLEVELSINCOMPLIANCE
WITHOCCUPATIONALSAFETYANDHEALTHADMINISTRATION
(OSHA)COMMERCIALORINDUSTRIALSTANDARDS.THISDEVICE
ISDESIGNEDTOPROTECTINDIVIDUALSFROMTHEACUTE
EFFECTSOFCARBONMONOXIDEEXPOSURE.ITWILLNOTFULLY
SAFEGUARDINDIVIDUALSWITHSPECIFICMEDICALCONDITIONS.
IFINDOUBTCONSULTAMEDICALPRACTITIONER.
Smoke/COAlarmsmaynotwakenallindividuals.Practicetheescape
planatleasttwiceayear,makingsurethateveryoneisinvolved–from
kidstograndparents.Allowchildrentomasterfireescapeplanningand
practicebeforeholdingafiredrillatnightwhentheyaresleeping.If
childrenorothersdonotreadilywakentothesoundoftheSmoke/CO
Alarm,orifthereareinfantsorfamilymemberswithmobilitylimitations,
makesurethatsomeoneisassignedtoassisttheminfiredrillandinthe
eventofanemergency.Itisrecommendedthatyouholdafiredrillwhile
familymembersaresleepinginordertodeterminetheirresponsetothe
soundoftheSmoke/COAlarmwhilesleepingandtodeterminewhether
theymayneedassistanceintheeventofanemergency.
Smoke/COAlarmscannotworkwithoutpower.Batteryoperatedunits
cannotworkifthebatteriesaremissing,disconnectedordead,ifthe
wrongtypeofbatteriesareused,orifthebatteriesarenotinstalled
correctly.ACunitscannotworkiftheACpoweriscutoffforanyreason
(openfuseorcircuitbreaker,failurealongapowerlineoratapower
station,electricalfirethatburnstheelectricalwires,etc.).Ifyouare
concernedaboutthelimitationsofbatteryorACpower,installbothtypes
ofunits.
ThisSmoke/COAlarmwillnotsensesmokeorCOthatdoesnotreach
thesensors.SmokeorCOItwillonlysensesmokeorCOatthesensor.
maybepresentinotherareas.Doorsorotherobstructionsmayaffect
therateatwhichCOorsmokereachesthesensors.Ifbedroomdoorsare
usuallyclosedatnight,werecommendyouinstallanAlarmdevice
(CombinationCOandSmokeAlarm,orseparateCOAlarmsandSmoke
Alarms)ineachbedroomandinthehallwaybetweenthem.
ThisSmoke/COAlarmmaynotsensesmokeorCOonanotherlevelof
thehome.RecommendedminimumprotectionisoneAlarmdevicein
everysleepingarea,everybedroom,andoneverylevelofyourhome.
SomeexpertsrecommendbatterypoweredsmokeandCOAlarmsbe
usedinconjunctionwithinterconnectedACpoweredSmokeAlarms.For
details,see"ABOUTSMOKEALARMS"onlinefordetails.
Smoke/COAlarmsmaynotbeheard.TheAlarmhornloudnessmeetsor
exceedscurrentULstandardsof85dBat10feet(3meters).However,if
theSmoke/COAlarmisinstalledoutsidethebedroom,itmaynotwake
upasoundsleeperoronewhohasrecentlyuseddrugsorhasbeen
drinkingalcoholicbeverages.Thisisespeciallytrueifthedoorisclosed
oronlypartlyopen.Noisefromtraffic,stereo,radio,television,air
conditioner,orotherappliancesmayalsopreventalertpersonsfrom
hearingtheAlarmhorn.ThisSmoke/COAlarmisnotintendedforpeople
whoarehearingimpaired.
NOTE:Individualswithmedicalproblemsmayconsiderusingwarning
deviceswhichprovideaudibleandvisualsignalsforcarbonmonoxide
concentrationsunder30ppm.
DANGER!
TheAlarmmaynothavetimetoAlarmbeforethefireitself
causesdamage,injury,ordeath,sincesmokefromsomefires
maynotreachtheunitimmediately.Examplesofthisinclude
personssmokinginbed,childrenplayingwithmatches,whena
person’sclothingcatchesfirewhilecooking,firescausedby
violentexplosionsresultingfromescapinggas,orincendiaryfires
wherethefiregrowssorapidlythatanoccupant’segressis
blockedevenwithproperlylocatedSmokeAlarms.
ThisSmoke/COAlarmisnotasubstituteforlifeinsurance.Thoughthis
Smoke/COAlarmwarnsagainstincreasingCOlevelsorthepresenceof
smoke,FirstAlertdoesnotwarrantorimplyinanywaythattheywill
protectlives.Homeownersandrentersmuststillinsuretheirlives.
ThisSmoke/COAlarmhasalimitedlife.AlthoughthisSmoke/COAlarm
andallofitspartshavepassedmanystringenttestsandaredesignedto
beasreliableaspossible,anyofthesepartscouldfailatanytime.
Therefore,youmusttestthisdeviceweekly.Theunitshouldbereplaced
immediatelyifitisnotoperatingproperly.
ThisSmoke/COAlarmisnotfoolproof.Likeallotherelectronicdevices,
thisSmoke/COAlarmhaslimitations.ItcanonlydetectsmokeorCOthat
reachesthesensors.Itmaynotgiveearlywarningofthesourceof
smokeorCOisinaremotepartofthehome,awayfromtheAlarm
device.
EvacuationPlanning
Establishandregularlypracticeaplanofescapeintheeventoffire.The
followingstepsarerecommendedbytheNationalFireProtection
Association:
1.
Positionyourdetectororyourinteriorand/orexteriorsoundersso
thattheycanbeheardbyalloccupants.
2.
Determinetwomeansofescapefromeachroom.Onepathof
escapeshouldleadtothedoorthatpermitsnormalexitfromthe
building.Theothermaybeawindow,shouldyourpathbe
impassable.Stationanescapeladderatsuchwindowsifthereisa
longdroptotheground.
3.
Sketchafloorplanofthebuilding.Showwindows,doors,stairsand
rooftopsthatcanbeusedtoescape.Indicateescaperoutesfor
eachroom.Keeptheseroutesfreefromobstructionandpost
copiesoftheescaperoutesineveryroom.
4.
Assurethatallbedroomdoorsareshutwhileyouareasleep.This
willpreventdeadlysmokefromenteringwhileyouescape.
5.
Trythedoor.Ifthedoorishot,checkyouralternateescaperoute.If
thedooriscool,openitcautiously.Bepreparedtoslamthedoorif
smokeorheatrushesin.
6.
Whensmokeispresent,crawlontheground.Donotwalkupright,
sincesmokerisesandmayovercomeyou.Clearerairisnearthe
floor.
7.
Escapequickly;don'tpanic.
Establishacommonmeetingplaceoutdoors,awayfromyourhouse,
whereeveryonecanmeetandthentakestepstocontactthe
authoritiesandaccountforthosemissing.Choosesomeoneto
assurethatnobodyreturnstothehouse-manydiegoingback.
Specifications
ELECTRICALSPECIFICATIONS
ACPower
120VAC@60Hz,0.7A
Battery(replaceable)
Two(2)-AABatteries
BatteryManufacturer
KendalLR6,EnergizerE91,orDuracell
MN1500
Battery(non-replaceable)
Lithium-ion
Sensitivity
UL/ULClimits2.4%/ft.obs±25%
AudibleSignal
3PulseTemporal(Smoke)&4Pulse
(CO)
AudibleAlarm
85dBminimumat10feet(3meters)
PHYSICALSPECIFICATIONS
Dimensions
5in.(127mm)Diameterx1.77in
(45mm)Depth
TrimRing
5.6in.(142.2mm)Diameter
Weight(includingbatteries)
Model
WithoutTrim
Ring
WithTrimRing
(18.6g)
SC2-W10/SC2-W10A208g226.6g
SC2-W01/SC2-W01A254.7g273.3g
SM2-W10/SM2-W10A197.2g215.8g
SM2-W01/SM2-W01A243.6g262.2g
OperatingTemperature
40°-100°F(4.4°-38°C)
StorageTemperatureRange
14-158°F(-10-70°C)
OperatingHumidityRange
20-95%RH(AgencyCompliance–
93%max.)non-condensing
APPROVALLISTINGS
FCC/IC,Conformsto:UL217&UL
2034,Canada:CSA6.19
Anyattempttoreverse-engineerthisdevicebydecodingproprietaryprotocols,
de-compilingfirmware,oranysimilaractionsisstrictlyprohibited.
Theproductshouldnotbedisposedofwithotherhouseholdwaste.Checkfor
thenearestauthorizedcollectioncentersorauthorizedrecyclers.Thecorrect
disposalofend-of-lifeequipmentwillhelppreventpotentialnegative
consequencesfortheenvironmentandhumanhealth.
06
LimitedWarranty
Forwarrantyinformation,pleasegoto:
https://resideo.info/US-Warranty-FA-Safety
Toreceiveaprintedversionofthewarranty,call
ResideoCustomerServiceat1-800-323-9005anda
copywillbemailedtoyoufreeofcharge.
Foryourrecords,pleaserecord:
DatePurchased:_____________/____________/____________
WherePurchased:
DateInstalled(Month/Year):_____________/____________
Replacealarm10yearsafterinstallation.Pleasewritethedateinthe
spaceprovided:
_____________/____________Month/Year
ThealarmwillalsoprovideanaudibleEnd-of-LifeSignalapproximately
10yearsafterinstallationtoremindyoutoreplacetheunit.
PrintedinMexico
900-00658-001-00K1
07/26
C
30555743055574
Certifiedto
CAN/ULCSTDS531&
CSASTD6.19-17
ConformstoULSTD217
&ULSTD2034
©2026ResideoTechnologies,Inc.Allrightsreserved.Theseproductsare
manufacturedbyResideoTechnologies,Inc.anditsaffiliates.•Scottsdale,AZ
85254.•Canada-www.firstalert.ca/US-www.firstalert.com.

Beoordeel deze handleiding


Product specificaties

Merk: First Alert
Categorie: Gasmelder
Model: CO1

Heb je hulp nodig?

Als je hulp nodig hebt met First Alert CO1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden