INSTALLATION
WHERE TO INSTALL CO ALARMS
The National Fire Protection Association (NFPA) recommends that a CO
Alarm should be centrally located outside of each separate sleeping
area in the immediate vicinity of the bedrooms. For added protection,
install additional CO Alarms in each separate bedroom, and on every
level of your home.
If your bedroom hallway is longer than 40 feet (12 meters), install a CO
Alarm at BOTH ends of the hallway.
In a Single-level Home:
•Install at least one CO Alarm near or within each separate sleeping
area.
•For added protection, install an additional CO Alarm at least 20 feet
(6 meters) away from the furnace or fuel burning heat source.
In a Multi-level Home:
•Install at least one CO Alarm near or within each separate sleeping
area.
•For added protection, install at least one CO Alarm on each level of
the home.
•For added protection, install an additional CO Alarm at least 20 feet
(6 meters) away from the furnace or fuel burning heat source.
In Mobile Homes:
•Install CO Alarms on inside walls ONLY. Uninsulated outside walls
and roofs of mobile homes often transfer heat and cold from out-
doors. The Alarm should be located at least 6 inches (152 mm) from
all exterior walls and at least 12 inches (305 mm) from supply or
return vents.
WHERE CO ALARMS SHOULD NOT BE
INSTALLED
DO NOT LOCATE THIS CO ALARM:
•In garages, kitchens, furnace rooms, or in any extremely dusty, dirty
or greasy areas.
•Closer than 20 feet (6 meters) from a furnace or other fuel burning
heat source, or fuel burning appliances like a water heater.
•Within 5 feet (1.5 meters) of any cooking appliance.
•In extremely humid areas. This alarm should be at least 10 feet
(3 meters) from a bath or shower, sauna, humidifier, vaporizer, dish-
washer, laundry room, utility room or other source of high humidity.
•Inareaswheretemperatureiscolderthan40˚F(4.4˚C)orhotter
than100˚F(37.8˚C).Theseareasincludeunconditionedcrawl
spaces, unfinished attics, uninsulated or poorly insulated ceilings,
porches, and garages.
•In turbulent air, like near ceiling fans, heat vents, air conditioners,
fresh air returns, or open windows. Blowing air may prevent CO from
reaching the sensors.
•Outside the Mobile Home.
•In direct sunlight.
• This CO Alarm is designed for use inside a single-family home or
apartment. It is not meant to be used in common lobbies, hallways,
or basements of multi-family buildings unless working CO Alarms
are also installed in each family living unit. CO Alarms in common
areas may not be heard from inside individual family living units.
• This CO Alarm alone is not a suitable substitute for complete
detection systems in places which house many people, like hotels
or dormitories, unless a CO Alarm is also placed in each unit.
• DO NOT use this CO Alarm in warehouses, industrial or
commercial buildings, special-purpose non-residential buildings,
or airplanes. This CO Alarm is specifically designed for residential
use, and may not provide adequate protection in non-residential
applications.
BATTERY OPERATED CARBON MONOXIDE ALARM
WITH SILENCE FEATURE
USER’S MANUAL
Model
CO3-B01
900-00659-001-00 3/26 Printed in MexicoK1
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Carbon
Monoxide (CO) Alarm’s operation. If you are installing this CO Alarm
for use by others, you must leave this manual—or a copy of it—with the
end user.
© 2026 Resideo Technologies, Inc. All rights reserved. These products
are manufactured by Resideo Technologies, Inc. and its affiliates. •
Scottsdale,AZ85254•CustomerServiceTeam:(800)323-9005•
www.firstalert.com
INTRODUCTION
BASIC SAFETY INFORMATION
•Dangers, Warnings, and Cautions alert you to important
operating instructions or to potentially hazardous situations. Pay
special attention to these items.
•THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to
detect carbon monoxide from ANY source of combustion. It is NOT
designed to detect smoke, fire, or any other gas.
•This CO Alarm is approved for use in single-family residences.
It is NOT designed for marine use.
•This CO Alarm will only indicate the presence of carbon monoxide gas
at the sensor. Carbon monoxide gas may be present in other areas.
•The Silence Feature is for your convenience only and will not cor-
rect a CO problem. Always check your home for a potential problem
after any alarm. Failure to do so can result in injury or death.
•NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to “If
Your CO Alarm Sounds” for more information. Failure to do so can
result in injury or death.
•Test the CO Alarm once a week. If the CO Alarm ever fails to test
correctly, have it replaced immediately! If the CO Alarm is not work-
ing properly, it cannot alert you to a problem.
•This product is intended for use in ordinary indoor locations of
family living units. It is not designed to measure CO levels in com-
pliance with Occupational Safety and Health Administration (OSHA)
commercial or industrial standards. Individuals with medical condi-
tions that may make them more sensitive to
carbon monoxide may consider using warning devices which pro-
vide audible and visual signals for carbon monoxide concentrations
under 30 ppm. For additional information on carbon monoxide and
your medical condition contact your physician.
FCC Compliance
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the
interferencebyoneormoreofthefollowingmeasures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that
of the receiver.
•Consult the dealer or an experienced radio or TV technician for help.
Warning:Changesormodificationstotheproduct,notexpressly
approved by Resideo Technologies, Inc. and its Affiliates, could void the
user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is
subjecttothefollowingtwoconditions:(1)thisdevicemaynotcause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
HOW YOUR CO ALARM WORKS
GENERAL INFORMATION
•This CO Alarm does not operate without working batteries.
Removing the batteries, or failure to replace them at the end
of their service life, removes your protection.
A CO Alarm measures the CO levels in the air. It will alarm if CO levels
rise quickly (if the heat exchanger on your furnace breaks, for example),
or if CO is consistently present (a slow CO leak on a fuel-burning
appliance).
This Carbon Monoxide Alarm features a permanently installed sensor
andan85dBalarmhorn.Italsohasasilencefeaturetotemporarily
quiet the alarm horn.
THE PARTS OF YOUR CO ALARM
12345
6
LIMITED WARRANTY
First Alert’s limited warranty for safety products can be found by scanning the QR code provided below or visiting https://docs.resideo.com/warranty/first-alert-safety.htm:
GARAGE
SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS
BEDROOM
BEDROOM
HALL
LIVING ROOM
KITCHEN
BASEMENT
BEDROOM
REQUIRED TO MEET NFPA RECOMMENDATIONS
INSTALLING THE 9V BATTERY
1. Push and lift the battery door
down to open.
2. Install the 9 volt battery
(included) inside the battery
compartment as indicated.
Make sure the “+” and “–”
ends of each battery are
aligned properly.
3 Ensure battery is securely snapped into terminals by pushing in
direction of arrow in the diagram.
4. Close the battery door.
5. Push and hold the Test/Silence button on the cover until you hear
an acknowledge “chirp”. The alarm horn will sound 4 beeps, a pause,
then 4 beeps. The ALARM (RED) light will flash. The alarm sequence
should last 5-6 seconds. If it does not alarm, make sure the battery
is correctly installed, and test it again.
HOW TO INSTALL YOUR CO ALARM
Read “Where To Install Your CO Alarm” before starting.
Before you start installation, find the pair of self-adhesive labels includ-
ed with this CO Alarm. On each label write in the phone number of your
emergency responder (like 911) and a qualified appliance
technician. Place one label near the CO Alarm, and the other label
in the “fresh air” location you plan to go if the alarm sounds.
IF YOUR CO ALARM SOUNDS
Actuation of your CO Alarm indicates the presence of carbon monoxide
(CO) which can kill you. In other words, when your CO Alarm sounds,
you must not ignore it!
IF THE ALARM SIGNAL SOUNDS:
1. Operate the Test/Silence button.
2. Call your emergency services, fire department or 911. Write down
thenumberofyourlocalemergencyservicehere:
____________________________________________________________
3. Immediately exit to fresh air—outdoors or by an open door or win-
dow. Do a head count to check that all persons are accounted for.
Do not re-enter the premises, or move away from the open door
or window until the emergency services responder has arrived, the
premises have been aired out, and your CO Alarm remains in its nor-
mal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a
24-hour period, repeat steps 1-3 and call a qualified appliance
technician to investigate for sources of CO from fuel-burning
equipment and appliances, and inspect for proper operation of this
equipment. If problems are identified during this inspection have the
equipment serviced immediately. Note any combustion
equipment not inspected by the technician, and consult the
manufacturers’ instructions, or contact the manufacturers directly,
for more information about CO safety and this equipment. Make
sure that motor vehicles are not, and have not, been operating in
an attached garage or adjacent to the residence. Write down the
numberofaqualifiedappliancetechnicianhere:
____________________________________________________________
Alarms have various limitations. See “General Limitations of CO
Alarms” for details.
USING THE SILENCE FEATURE
• The Silence Feature is for your convenience only and will
not correct a CO problem. Always check your home for a potential
problem after any alarm. Failure to do so can result in injury or
death.
• NEVER remove the batteries from your CO Alarm to silence the
horn. Use the silence feature. Removing the batteries removes
your protection! See “If Your CO Alarm Sounds”
for details on responding to an alarm.
The Silence Feature is intended to temporarily silence your CO Alarm’s
alarm horn while you correct the problem—it will not correct a CO prob-
lem. While the alarm is silenced it will continue to monitor the air for CO.
When CO reaches alarm levels the alarm will sound— repeating horn
pattern:4beeps,apause,4beeps,etc.PressandholdtheTest/Silence
button until the horn is silent. The initial Silence cycle will last approxi-
mately 4 minutes.
NOTE:After initial 4-minute Silence cycle, the CO Alarm re-evaluates
present CO levels and responds accordingly. If CO levels remain
potentially dangerous—or start rising higher—the horn will start
sounding again.
While the detector is silenced:
WHAT YOU NEED TO KNOW ABOUT CO
WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels
do not burn completely, or are exposed to heat (usually fire). Electrical
appliances typically do not produce CO.
Thesefuelsinclude:Wood, coal, charcoal, oil, natural gas, gasoline, ker-
osene, and propane.
Common appliances are often sources of CO. If they are not properly
maintained, are improperly ventilated, or malfunction, CO levels can rise
quickly. CO is a real danger now that homes are more energy
efficient. “Air-tight” homes with added insulation, sealed windows, and
other weatherproofing can “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be
discussed with ALL household members.
MildExposure:
Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).
MediumExposure:
Throbbing headache, drowsiness, confusion, fast heart rate.
ExtremeExposure:
Convulsions, unconsciousness, heart and lung failure. Exposure to
carbon monoxide can cause brain damage, death.
Some individuals are more sensitive to CO than others, including people
with cardiac or respiratory problems, infants, unborn babies, pregnant
mothers, or elderly people can be more quickly and severely affected by
CO. Members of sensitive populations should consult their doctors for
advice on taking additional precautions.
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it dif-
ficult to locate the source of CO after an alarm. These are a few of the
factorsthatcanmakeitdifficulttolocatesourcesofCO:
•House well ventilated before the investigator arrives.
•Problem caused by “backdrafting.”
•Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may be
difficult to locate the source of CO. Resideo Technologies, Inc. and its
Affiliates shall not be obligated to pay for any carbon monoxide investi-
gation or service call.
HOW CAN I PROTECT MY FAMILY?
A CO Alarm is an excellent means of protection. It monitors the air and
sounds a loud alarm before carbon monoxide levels become threatening
for average, healthy adults.
A CO Alarm is not a substitute for proper maintenance of home
appliances.
TohelppreventCOproblemsandreducetheriskofCOpoisoning:
•Clean chimneys and flues yearly. Keep them free of debris, leaves,
and nests for proper air flow. Also, have a professional check for
rust and corrosion, cracks, or separations. These conditions can
prevent proper air movement and cause backdrafting. Never “cap”
or cover a chimney in any way that would block air flow.
•Test and maintain all fuel-burning equipment annually. Many local
gas or oil companies and HVAC companies offer appliance
inspections for a nominal fee.
•Make regular visual inspections of all fuel-burning appliances. Check
appliances for excessive rust and scaling. Also check the flame on
the burner and pilot lights. The flame should be blue. A yellow flame
means fuel is not being burned completely and CO may be present.
Keep the blower door on the furnace closed. Use vents or fans when
they are available on all fuel-burning appliances. Make sure applianc-
es are vented to the outside. Do not grill or barbecue indoors, or in
garages or on screen porches.
•Check for exhaust backflow from CO sources. Check the draft hood
on an operating furnace for a backdraft. Look for cracks on furnace
heat exchangers.
•Check the house or garage on the other side of shared wall.
•Keep windows and doors open slightly. If you suspect that CO is
escaping into your home, open a window or a door. Opening
windows and doors can significantly decrease CO levels.
In addition, familiarize yourself with all enclosed materials. Read this
manual in its entirety, and make sure you understand what to do if your
CO Alarm sounds.
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO
Alarms to sound when exposed to levels of CO and exposure times as
described below. They are measured in parts per million (ppm) of CO
over time (in minutes).
UL2034 Required Alarm Points*:
•If the alarm is exposed to 400 ppm of CO, IT MUST ALARM
BETWEEN 4 and 15 MINUTES.
•If the alarm is exposed to 150 ppm of CO, IT MUST ALARM
BETWEEN 10 and 50 MINUTES.
•Ifthealarmisexposedto70ppmofCO,ITMUSTALARMBETWEEN
60 and 240 MINUTES.
* Approximately 10% COHb exposure at levels of 10% to 95% Relative
Humidity (RH). The unit is designed not to alarm when exposed to a con-
stant level of 30 ppm for 30 days.
CO Alarms are designed to alarm before there is an immediate life
threat. Since you cannot see or smell CO, never assume it’s not present.
•An exposure to 100 ppm of CO for 20 minutes may not affect
average, healthy adults, but after 4 hours the same level may cause
headaches.
•An exposure to 400 ppm of CO may cause headaches in average,
healthy adults after 35 minutes, but can cause death after 2 hours.
This CO Alarm measures exposure to CO over time. It alarms if CO
levels are extremely high in a short period of time, or if CO levels reach a
certain minimum over a long period of time. The CO Alarm generally
sounds an alarm before the onset of symptoms in average, healthy
adults.
Why is this important? Because you need to be warned of a potential
CO problem while you can still react in time. In many reported cases
of CO exposure, victims may be aware that they are not feeling well,
but become disoriented and can no longer react well enough to exit
the building or get help. Also, young children and pets may be the first
affected. The average healthy adult might not feel any symptoms when
the CO Alarm sounds. However, people with cardiac or respiratory prob-
lems, infants, unborn babies, pregnant mothers, or elderly people can be
more quickly and severely affected by CO. If you experience even mild
symptoms of CO poisoning, consult your doctor immediately!
Standards: Underwriters Laboratories Inc. Single and Multiple Station
carbon monoxide alarms UL2034.
AccordingtoUnderwritersLaboratoriesInc.UL2034,Section1-1.2:
“Carbon monoxide alarms covered by these requirements are intended
to respond to the presence of carbon monoxide from sources such as,
but not limited to, exhaust from internal-combustion engines, abnormal
operation of fuel-fired appliances, and fireplaces. CO Alarms are intended
to alarm at carbon monoxide levels below those that could cause a loss
of ability to react to the dangers of Carbon Monoxide exposure.” This CO
Alarm monitors the air at the Alarm, and is designed to alarm before CO
levels become life threatening. This allows you precious time to leave
the house and correct the problem. This is only possible if Alarms are
located, installed, and maintained as described in this manual.
GasDetectionatTypicalTemperatureandHumidityRanges: The CO
Alarm is not formulated to detect CO levels below 30 ppm typically.
UL tested for false alarm resistance to Methane (500 ppm), Butane (300
ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol
(200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and
vapor concentrations in parts per million.
AudibleAlarm:85dBminimumat10feet(3meters).
TESTING & MAINTENANCE
WEEKLY TESTING
•Test the CO Alarm once a week. If the CO Alarm ever fails to test
correctly, have it replaced immediately! If the CO Alarm is not working
properly, it cannot alert you to a problem.
•DO NOT stand close to the Alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
Push and hold the Test/Silence button on the cover until you hear an
acknowledge “chirp”. The alarm horn will sound 4 beeps, a pause, then 4
beeps. The ALARM (RED) light will flash.
The alarm sequence should last 5-6 seconds. If it does not alarm, make
sure fresh batteries are correctly installed, and test it again. If the unit
still does not alarm, replace it immediately.
If the alarm does not test properly:
1. Make sure that fresh batteries are installed correctly.
2. Be sure the Alarm is clean and dust-free.
3. Install a fresh 9 volt battery and test the Alarm again.*
•DO NOT try fixing the Alarm yourself –this will void your warranty!
If the CO Alarm is still not operating properly, and it is still under
warranty, please see “How to Obtain Warranty Service” in the Limited
Warranty. Install a new CO Alarm immediately.
•The Test/Silence button is the only proper way to test the CO Alarm.
NEVER use vehicle exhaust! Exhaust may cause permanent damage
and voids your warranty.
*For a list of acceptable replacement batteries, see “Regular Maintenance.”
REGULAR MAINTENANCE
To keep the CO Alarm in good working order:
•Test it every week using the Test/Silence button.
•Vacuum the CO Alarm cover once a month, using the soft brush
attachment. Never use water, cleaners, or solvents, since these may
damage the unit. Test the CO Alarm again after vacuuming.
•Replace the battery when the CO Alarm “chirps”about every minute
(the low battery warning).
Thelowbatterywarningshouldlastfor7days,butyoushouldreplace
the battery immediately to continue your protection.
Choosing a replacement battery:
This CO Alarm requires one standard 9 volt battery. The following
batteriesareacceptableasreplacements:DuracellMN1604,Energizer
522, and Ultralife U9VL-J-P. These replacement batteries are commonly
available at local retail stores.
•Always use the exact batteries specified by this User’s Manual. DO
NOT use rechargeable batteries. Clean the battery contacts and also
those of the device prior to battery installation. Install batteries cor-
rectly with regard to polarity (+ and -).
•Please dispose of or recycle used batteries properly, following any
local regulations. Consult your local waste management authority or
recycling organization to find an electronics
recycling facility in your area. DO NOT DISPOSE OF BATTERIES IN
FIRE. BATTERIES MAY EXPLODE OR LEAK.
•Keep battery out of reach of children. In the event a battery
is swallowed, immediately contact your poison control center, your
physician, or the National Battery Ingestion hotline at
202-625-3333 as serious injury may occur.
•DO NOT spray cleaning chemicals or insect sprays directly on or
near the CO Alarm. DO NOT paint over the CO Alarm. Doing so may
cause permanent damage.
Household cleaners, aerosol chemicals, and other contaminants can
affect the sensor. When using any of these materials near the CO Alarm,
make sure the room is well ventilated.
CO ALARM
Sensor has detected enough CO to trigger an alarm. Light flashes
rapidly and horn sounds loudly (repeating
4 beeps, pause)
. See “If Your
CO Alarm Sounds” for details. During an alarm, move everyone to a
source of fresh air. DO NOT move the CO Alarm!
DURING TESTING
Light flashes Red in sync with the horn pattern
(4 beeps, pause,
4 beeps)
, simulating a CO Alarm condition.
UNDERSTANDING YOUR CO ALARM
LOW BATTERY WARNING
The light continues to flash (RED) and the horn also “chirps” once
everyminute.Thiswarningshouldlastforupto7days,butyoushould
replace the battery as soon as possible.
ALARM RECEIVING BATTERY POWER
Light flashes every minute. Horn is silent.
CO ALARM REQUIRES SERVICE (MALFUNCTION SIGNAL)
The light flashes (RED) and the horn sounds 3 “chirps” every minute.
CO Alarm needs to be replaced.
CO ALARM HAS REACHED ITS END OF LIFE
The light flashes (RED) and the horn sounds 5 “chirps” every minute.
CO Alarm needs to be replaced.
–
–
TO MOUNT ON THE WALL
Toolsyouwillneed: Pencil, Drill with 3/16” or 5mm drill bit,
Flathead Screwdriver, Hammer.
1. Choose a location on the wall. Do not install the Alarm closer than
4” (102 mm) from where the wall meets the ceiling.
2. Hold the mounting guide template against the wall, and make a
mark inside each keyhole where you will drill your mounting hole as
shown in the diagram below.
3. Use a 3/16” (5 mm) drill bit to drill through the marks you made for
the mounting holes.
4. Insert the plastic screw anchors into the mounting holes until they
are flush with the wall. If necessary, tap them gently with a hammer.
5.Insertthescrewsintotheanchorsuntilthescrewheadis1/8inch
(3 mm) away from the wall.
6. Slide the CO Alarm onto the screws until you feel it click into place.
7.TesttheCOAlarmasdescribedin“WeeklyTesting.”
“ALARM-EXIT TO FRESH AIR”
If you hear the alarm horn and the Red light is flashing,
move everyone to a source of fresh air.
DO NOT disconnect the batteries from the CO Alarm!
Fuel-burningapplianceslike: portable heater, gas or wood burning fire-
place, gas kitchen range or cooktop, gas clothes dryer.
Damagedorinsufficientventing:corroded or disconnected water heat-
er vent pipe, leaking chimney pipe or flue, or cracked heat exchanger,
blocked or clogged chimney opening.
Improperuseofappliance/device:operating a barbecue grill or
vehicle in an enclosed area (like a garage or screened porch).
TransientCOProblems:“transient”or on-again-off-again CO
problems can be caused by outdoor conditions and other special
circumstances.
This CO Alarm is intended for residential use. It is not intended for
use in industrial applications where Occupational Safety and Health
Administration (OSHA) requirements for carbon monoxide detectors must
be met.
CO alarms may not waken all individuals.If children or others do not
readily waken to the sound of the CO alarm, or if there are infants or
family members with mobility limitations, make sure that someone is
assigned to assist them in the event of an emergency.
CO Alarms will not work without power. This alarm requires one
standard 9 volt battery to operate.
CO Alarms for Solar or Wind Energy users and battery backup power
systems: AC powered CO Alarms should only be operated with true
or pure sine wave inverters. Operating this Alarm with most battery-
powered UPS (uninterruptible power supply) products or square wave
or “quasi sine wave” inverters will damage the Alarm. If you are not sure
about your inverter or UPS type, please consult with the manufacturer to
verify.
This CO Alarm will not sense carbon monoxide that does not reach
the sensor. This CO Alarm will only sense CO at the sensor. CO may be
present in other areas. Doors or other obstructions may affect the rate at
which CO reaches the CO Alarm. For this reason, if bedroom doors are
usually closed at night, we recommend you install a CO Alarm in each
bedroom and in the hallway between them.
CO Alarms may not sense CO on another level of the home.
For example, a CO Alarm on the second level, near the bedrooms, may not
sense CO in the basement. For this reason, one CO Alarm may not give
adequate warning. Complete coverage is recommended. Place CO Alarms
on each level of the home.
CO Alarms may not be heard. The alarm horn loudness meets or
exceedscurrentULstandardsof85dBat10feet(3meters).However,
if the CO Alarm is installed outside the bedroom, it may not wake up a
sound sleeper or one who has recently used drugs or has been drinking
alcoholic beverages. This is especially true if the door is closed or only
partly open. Even persons who are awake may not hear the alarm horn
if the sound is blocked by distance or closed doors. Noise from traffic,
stereo, radio, television, air conditioner, or other appliances may also
prevent alert persons from hearing the alarm horn. This CO Alarm is not
intended for people who are hearing impaired.
CO Alarms are not a substitute for a smoke alarm. Although fire is a
source of carbon monoxide, this CO Alarm does not sense smoke or
fire. This CO Alarm senses CO that may be escaping unnoticed from
malfunctioning furnaces, appliances, or other sources. Early warning of
fire requires the installation of smoke alarms.
CO Alarms are not a substitute for life insurance. Though these CO
Alarms warn against increasing CO levels, Resideo Technologies, Inc.
and its Affiliates do not warrant or imply in any way that they will protect
lives from CO poisoning. Homeowners and renters must still insure their
lives.
CO Alarms have a limited life. Although the CO Alarm and all of its parts
have passed many stringent tests and are designed to be as
reliable as possible, any of these parts could fail at any time. Therefore,
you must test your CO Alarm weekly.
CO Alarms are not foolproof. Like all other electronic devices, CO Alarms
have limitations. They can only detect CO that reaches their
sensors. They may not give early warning to rising CO levels if the CO
is coming from a remote part of the home, away from the CO Alarm.
GENERAL LIMITATIONS OF CO ALARMS
The following conditions can result in transient CO situations:
1. Excessive spillage or reverse venting of fuel appliances caused by
outdoorconditionssuchas:
•Wind direction and/or velocity, including high, gusty winds.
Heavy air in the vent pipes (cold/humid air with extended periods
between cycles).
•Negative pressure differential resulting from the use of exhaust
fans.
•Several appliances running at the same time competing for limited
fresh air.
•Vent pipe connections vibrating loose from clothes dryers,
furnaces, or water heaters.
•Obstructions in or unconventional vent pipe designs which can
amplify the above situations.
2. Extended operation of unvented fuel burning devices (range, oven,
fireplace).
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your
home. Since these conditions can come and go, they are also hard to
recreate during a CO investigation.
POTENTIAL SOURCES OF CO IN THE HOME
REGULATORY INFORMATION FOR CO ALARMS
Printed in Mexico 900-00659-001-00 3/26K1
If the CO Alarm...
Is silent for only 4 minutes,
then starts sounding loudly—4
beeps, pause, 4 beeps, pause
This means...
CO levels are still potentially
dangerous.
If the CO Alarm...
Remains silent after you
pressed the Test/Silence
button
This means...
CO levels are dropping.
CO Alarm goes back into alarm 4 minutes after
you press the Test/Silence button.
CO levels indicate a potentially dangerous
situation.
IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call
911 or the Fire Department. If not, press the Test/
Silence button again and keep ventilating your home.
The light flashes (RED) and the horn sounds
3 “chirps” every minute.
MALFUNCTION SIGNAL. CO Alarm needs to be
replaced.
CO Alarms under warranty should be returned to
manufacturer for replacement. See “Limited
Warranty” for details.
PROBLEM...THIS MEANS...YOU SHOULD...
The light continues to flash (RED) and the horn
“chirps” once every minute.
Low battery warning.Install 1 new 9 volt battery*.
TROUBLESHOOTING GUIDE
CO Alarm sounds frequently even though no high
levels of CO are revealed in an investigation.
The CO Alarm may be improperly located. Refer
to “Where to Install CO Alarms.”
Relocate your alarm. If frequent alarms continue,
have home rechecked for potential CO problems.
You may be experiencing an intermittent CO
problem.
The light flashes (RED) and the horn sounds
5 “chirps” every minute.
END OF LIFE SIGNAL. CO Alarm needs to be replaced.Immediately replace the CO Alarm.
Ifyouhaveanyquestionsthatcannotbeansweredbyreadingthismanual,callConsumerAffairsat1-800-323-9005.
*Foralistofacceptablereplacementbatteries,see“Page4:RegularMaintenance.”
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning
“chirp”forupto8hours.Youcansilencethelowbatterywarning“chirp”
by pressing the Test/Silence button. Activation of low battery silence is
acknowledged with a “chirp”.
After8hours,thelowbattery“chirp”willresume.Replace the
batteries as soon as possible; this unit will not operate without battery
power!
If you cannot silence the low battery warning, replace the
batteries immediately.
1 Open door (in back)
2 Battery Compartment (in back)
3 Test/Silence Button
4 POWER/ALARM Light (RED)
5(BehindCover)AlarmHorn:
85dBaudiblealarmfortest,
alarm, and unit malfunction
warning.
CONFORMS TO
UL STD 2034
SILENCING THE END OF LIFE SIGNAL
This silence feature can temporarily quiet the End of Life warning “chirp”
for up to 2 days. You can silence the End of Life warning “chirp” by
pressing the Test/Silence button. The horn will chirp, acknowledging
that the End of Life silence feature has been activated.
After approximately 2 days, the End of Life “chirp” will resume.
For your records, please record:
Date Purchased: ____________Where Purchased: _________________
Date Installed: ____________/____________Month/Year
Replace alarm 5 years after installation. Please write the date in the
space provided:
_____________/____________Month/Year
The alarm will also provide an audible End-of-Life Signal
approximately 7 years after installation to remind you to replace the unit.
The End-of-Life Signal can be silenced for up to 2 days. Do not unplug
the alarm or remove the batteries until you get replacement.
3
4
1 & 2
5
Product specificaties
| Merk: | First Alert |
| Categorie: | Gasmelder |
| Model: | CO3 |
Heb je hulp nodig?
Als je hulp nodig hebt met First Alert CO3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Gasmelder First Alert
7 September 2026
25 Januari 2023
4 December 2022
Handleiding Gasmelder
Nieuwste handleidingen voor Gasmelder
11 Juli 2026
28 April 2026
21 Maart 2026
11 Maart 2026
9 Maart 2026
6 Maart 2026
5 Maart 2026
3 Januari 2026
1 Januari 2026
1 Januari 2026