Festo VABM-B10-30E-G34-3 Handleiding

Festo Niet gecategoriseerd VABM-B10-30E-G34-3

Bekijk gratis de handleiding van Festo VABM-B10-30E-G34-3 (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.7 sterren uit 1.5 reviews. Heb je een vraag over Festo VABM-B10-30E-G34-3 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
Assembly instructions (Original instructions)
8067325
1701b
[8067327]
†‡
Connection block
VABM-B10-30E
Festo SE & Co. KG
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
1. Applicable documents
All available documents on the product www.
festo.com/pk
2. Safety
Switch off compressed air before mounting work.
Observe tigh
tening torques.
3. Intended use
Pneuma
tic linking of the valves.
4. Further inf
o
rmation
Accessories for VABM www.fes
to.com/catalogue
5. Scope of delivery
2148
1d
_1
VABM-B10-30E-...
1 Connection block
2 Screw M5x60
1)2)
3 Seal
1)2)
4 Seal
1)
5 Blanking plug B-3/4
6 Blanking plug B-1/8
(1x)
(nx)
(nx)
(nx)
(3x)
(2x)
2148
1d
_2
VABM-B10-30E-...-P3
1 Connection block
2 Screw M5x60
1)2)
3 Seal
1)
4 Seal
1)
5 Blanking plug B-3/4
6 Blanking plug B-1/8
(1x)
(nx)
(nx)
(nx)
(2x)
(1x)
6. Not in scope of d
e
livery
2148
1d
_9
7 Solenoid valve
VUVS-... or
pneumatic valve
VUWS-...
1)
8 Screw set
1)
VABM-B10-30-S
only for VUVS-LK…-S,
with screws
(nx)
(nx)
21481d_14
ISO 4762-M5x40-10.9
1)
The number of screws , seals 2 8/3 4/ and valves 7 is dependent on the available
valve positions.
2)
Number = 2 x available valve positions
7. Mounting of blanking plugs 5
5
5
55/6
6
6
66
2148
1d_5
Screw in the blanking
plugs 5 6/ at the desired
position, as required.
Blanking plug [Nm]
535 _ 10 %
63.5 _ 20 %
8. Mounting of connection block 1
1
1
11
2148
1d
_6
Place connection block 1
on mounting surface (A).
Tighten screws (B).
9. Alignment of seal 4
4
4
44
2148
1d_8
For valves VUVS-L/LT...:
Place the seal 4 into the
depression of the valve 7
so that it is positive-locking.
Observe channel
designations 1/3/5 or 1/3.
2148
1d_1
3
For valves VUVS-LK...-S:
Place seal 4 on the
valve 7. Observe channel
designation 1/3/5 or 1/3.
Indexing hole (X) on the
valve 7 is:
Only relevant for connection
block VABM-B10-30E-...
Hidden after alignment
of the seal 4.
10. Mounting of valve 7
7
7
7 7
Information
Screws 8 can only be mounted with solenoid valves 7 VUVS-LK…-S.
Seals 3 can only be mounted for solenoid valves 7 with external pilot air
supply.
21
48
1d
_7
Push screws 2 8/ into the
drill holes of the valve 7.
Only screws 2 are loss-
protected.
Insert seals 3 into the
orifices (C). Rotating
movement required during
mounting.
Position valve 7 on the
connection block 1.
Check:
Projection (D) is in the slot (E)
Valve 7 is aligned parallel to the surface (F)
Channel designations 1/3/5 or 1/3 agree with each other.
Tighten screws 2 8/ .
6 Nm _ 20 %
2
/
8
1
1
5
6
2
3
4
1
5
6
2
3
4
A
B
7
4
3
C
E
1
F
7
4
D
5 1
3
6
5
7
7
4
C
5 1
3
X X
8


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: VABM-B10-30E-G34-3

Heb je hulp nodig?

Als je hulp nodig hebt met Festo VABM-B10-30E-G34-3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden