Bekijk gratis de handleiding van Festo VABM-B10-20S-G14-5-P3 (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.3 sterren uit 1.5 reviews. Heb je een vraag over Festo VABM-B10-20S-G14-5-P3 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
Assembly instructions (Original instructions)
8067309
1701b
[8067311]
†‡
Connection block
VABM-B10-20S
Festo SE & Co. KG
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
1. Applicable documents
All available documents for the product www.f
esto.com/pk
2. Safety
Switch off compressed air before mounting work.
Observe tigh
tening torques.
3. Intended use
Pneumatic linking of the valves.
4. Further info
rmation
Accessories for VABM www.fes
to.com/catalogue
5. Scope of delivery
20272d_3
VABM-B10-20S-...
1 Connection block
2 Screw M3x40
1)2)
3 Screw M3x30
1)2)
4 Seal
1)
5 Blanking plug B-1/4
(1x)
(nx)
(nx)
(nx)
(3x)
20272d_4
VABM-B10-20S-...-P3
1 Connection block
2 Screw M3x40
1)2)
3 Screw M3x30
1)2)
4 Seal
1)
5 Blanking plug B-1/4
(1x)
(nx)
(nx)
(nx)
(2x)
6. Not in scope of delivery
20260d_3
6 Solenoid valve
VUVS-… or
pneumatic valve
VUWS-...
1)
(nx)
1)
The number of screws , seals 2 3/4 and valves 6 is dependent on the available valve
positions.
2)
Number = 2 x available valve positions
7. Mounting of blanking plugs 5
5
5
55
20272d_9
Screw in the blanking
plugs 5 at the desired
position, as required.
Blanking plug [Nm]
58.5 _ 15 %
8. Mounting of connection b
l
ock 1
1
1
11
20272d_11
Place connection block 1
on mounting surface (A).
Tighten screws (B).
9. Alignment of seal 4
4
4
44
20272d_8
For valves VUVS-L/LT...:
Place the seal 4 in the
depression of the valve 6
so it is positive-locking.
Observe channel
designation 1/3/5 or 1/3.
20272d_12
For valves VUVS-LK...-S:
Place seal 4 on the
valve 6. Observe channel
designation 1/3/5 or 1/3.
Indexing hole (X) on the
valve 6 is:
only relevant for the
connection block
VABM-B10-20S-...
hidden according to the
alignment of the seal 4.
10. Mounting valve 6
6
6
66
Information
Screws 3 can only be mounted with solenoid valves 6 VUVS-LK…-S.
20272d_10
/Push screws 2 3 into the
drill holes of the valve 6.
Only screws 2 are
loss-protected.
Position valve 6 on the
connection block 1.
Check:
Projection (C) is in the
slot (D)
Valve 6 is aligned parallel
to the surface (E)
Channel designations 1/3/5
or 1/3 agree with each
other.
Tighten screws 2 3/ .
6
1.4 Nm _ 20 %
2
/
3
1
1
5
2
4
1
5
2
4
A
B
6
4
D
1
E
3
3
5
6
4
C
315
6
4
C
315
X
X
X


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: VABM-B10-20S-G14-5-P3

Heb je hulp nodig?

Als je hulp nodig hebt met Festo VABM-B10-20S-G14-5-P3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden