Bekijk gratis de handleiding van Festo EFSD-100-PV-M12 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 9 mensen en kreeg gemiddeld 4.8 sterren uit 6 reviews. Heb je een vraag over Festo EFSD-100-PV-M12 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/4
Translation of the original instructions
1Further applicable documents
All available documents for the product www.festo.com/pk.è
2Safety
2.1General safety informations
Observe labelling on the product.
Prior to mounting, installation and maintenance work: Switch off power supply
and secure it from being switched back on.
ment. Ensure that storage times are kept to a minimum.
Comply with the handling specifications for electrostatically sensitive devices.
Observe tightening torques. Unless otherwise specified, the tolerance is
±20%.
2.2Intended use
Fig. 1
The EFSD electric stopper cylinder is intended for use in stopping the transported
material.
This product can generate high frequency interference, which may make it neces-
sary to implement interference suppression measures in residential areas.
2.3Training of specialised personnel
Installation, commissioning, maintenance and disassembly should only be con-
ducted by qualified personnel.
The qualified personnel must be familiar with installation of electrical control sys-
tems.
3Further information
Accessories www.festo.com/catalogue.è
Spare parts www.festo.com/spareparts.è
4Service
Contact your regional Festo contact person if you have technical questions
èwww.festo.com.
4.1Function
The electric stopper cylinder isolates/stops transported material in transfer sys-
tems. Cushioning over a stop is done through an air cushion. Retraction of the
stop (release of transported material) and the position inquiry are done electric-
ally.
There are 3 positions:
Fig. 2
Position 1:
Stopper cylinder closed in initial position (closed):
Stop is extended and located in the initial position. The stopper cylinder is
ready to stop a transported material.
Position 2:
Stopper cylinder closed in stop position (closed):
The stopper cylinder travels to the stop and moves the stop from the initial pos-
ition into the stop position. This causes the transported material to be braked
and then stopped through internal dampening.
Position 3:
Stopper cylinder opened (open):
Stop retracts and releases the transported material.
4.2Configuration
1
Electrical connection (actuator),
M12 plug (5-pin)
2
Electrical connection (sensor), M12
plug (5-pin)
3
LED display (power): operating
status
4
LED display (open): stop retracted
5
LED display (closed): stop exten-
ded
6
Cushioning setting
7
Stop
8
Mounting interface
Fig. 3
5Installation
Requirements
Do not modify the screws and threaded pins. Exception: Immediate demand for
modification in this instruction manual.
Install product without tension or distortion. Evenness of the mounting surface
must be maintained within 0.1mm.
8061883
Stopper cylinder
EFSD
8061883
2017-06
[8061885]
Instructions - Operation
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com

Beoordeel deze handleiding

4.8/5 (6 Beoordelingen)

Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: EFSD-100-PV-M12

Heb je hulp nodig?

Als je hulp nodig hebt met Festo EFSD-100-PV-M12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden