Bekijk gratis de handleiding van EXSYS EX-60350 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 4.5 sterren uit 8 reviews. Heb je een vraag over EXSYS EX-60350 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

6
5
1
AUFBAU
CONNECTORS & STATUS LEDsHARDWAREINSTALLATION
Anleitun
E6035
Switzerland:
EXSYS Vertriebs GmbH
Dübendorfstrasse 17
8602 Wangen
www.exsys.ch
Germany:
EXSYS Vertriebs GmbH
Industriestrasse 8
61449 Steinbach
www.exsys.de
Italy:
EXSYS Italia Srl
Via Belvedere, 45/B
I22100 Como -
www.exsys.it
Mit dem 10 Gigabit Ethernet PoEInjektor EX60350 im robusten Metallgehäuse können --
Endgeräte wie IPTelefone, IPKameras, WLAN Access Points etc. über das Netzwerkkabel mit --
Strom versorgt werden. Er integriert zwei unabhängige PoE++ Injektoren mit einer maximalen
Gesamtleistung von 90 W und Übertragungsraten bis 10 Gbit/s. Die Stromversorgung erfolgt
über den Terminal Block (12 bis 48 VDC) und kann zur Verminderungen von Betriebsausfällen
auch redundant erfolgen. Durch das robuste Metallgehäuse und den erweiterten
Betriebstemperaturbereich von 40°C bis 80°C ist er für eine Vielzahl von Anwendungen auch in -
rauen Umgebungen geeignet. Zum Lieferumfang gehören ein vormontiertes DINRailKit und --
eine Wandmontagehalterung.
BESCHREIBUNG & TECHNISCHE DATEN
Kompatibilität:Gigabit Ethernet 10/100/1000/2500BaseT, 5/10GBaseT10 --
PoE:IEEE 802.3af/at/bt (PoE++)
- 802.3af, Typ 1:15.40 W (PSE), 12.95 W (PD)
- 802.3at, Typ 2:30.00 W (PSE), 25.50 W (PD)
- 802.3bt, Typ 3:60.00 W (PSE), 51.00 W (PD)
- 802.3bt, Typ 4:90.00 W (PSE), 71.00 W (PD)
Betriebssysteme:Alle Betriebssysteme
Anschlüsse:4x RJ45Buchse1x Terminal Block 12~48VDC-,
Lieferumfang:60350, DINRail Kit, Wandmontagehalterung, AnleitungEX--
Status LEDs
12--48V TBlock für optional
erhältliches Netzteil
ACHTUNG!
Bei geerdetem Minuspol der Stromversorgung
unbedingt den Technischen Hinweis auf Seite 3
beachten.
Please read the following installation instructions.
1.--Install the EX60350 on a mounting rail using the DINRail kit or on the wall using the wall
mounting brackets.
2.Connect the power connector of the optionally available power supply to the terminal block
and turn on the power supply.
3.When the power is turned on, the PWR indicator lights up. If the indicator is not lit, check
for proper connection to the power supply.
4. Connect your router to a RJ45 input of the PoE injector.
5. Now connect your PoE PD device to the corresponding PoE port.
6.If all cables are connected correctly, the indicators light according to the port status of the
LEDs (page 5).
The DINRail Kit is preassembled with --
two screws on the rear side
To install the wall mount, the DIN-
Rail kit must be replaced by the
mounting bracket
To clean the unit, use only a dry, lintfree cloth and apply light pressure to remove dirt. Take -
care not to leave any fibres of the cloth in the connectors.
Never use a damp or wet cloth for cleaning!
CLEANING
TECHNICAL NOTE
Procedure for STP Cable Grounding
When using shielded cables to connect two Ethernet devices, a ground loop may occur if the
shielding on the cables generates an additional grounding connection path. This can cause
ground current to flow through to the Ethernet ports and damage the devices. If it is necessary
to use shielded cables, we recommend using a metallic RJ45 connector on one end and a non-
metallic connector on the other end. Alternatively, a patch panel can be used in between the
two devices to prevent ground loops from occurring.
For connections over short distances (e.g., between two devices installed in the same cabinet),
both ends of the shielded cable can be referenced to the same grounding point. Therefore, in
this case, it is acceptable to use a shielded cable with metallic RJ45 connectors on both
devices.
Power LED
PoE LED
12V to 48V TBlock:-
ATTENTION!
Please pay attention to the correct polarity!
Never connect the power supply to the terminal block while it
is switched on!
Status LEDs:
LED NameColorLED Function
PowerGreen
On:Powered
Off:no power connection
PoE
Green
On:PoE activated
Blinking:Power Device (PD) detected
Off: no (PD) deviceconnected
RJ45 Port:
RJ45 Port
PinSignalPoEPinSignalPoE
Mode AMode BMode AMode B
1BI_DA+VCC+5BI_DCVCC+ -
2BI_DAVCC+6BI_DBVCC- - -
3BI_DB+VCC7BI_DD+VCC - -
4BI_DC+VCC+8BI_DDVCC - -
V+ V-
Power over Ethernet IEEE802.3af/at/bt (PoE++ / 4PPoE)
87654321
RJ45Downlink 1&2-
(PoE/Daten)
RJ45Uplink 1&2-
(Daten)
Product specificaties
| Merk: | EXSYS |
| Categorie: | Niet gecategoriseerd |
| Model: | EX-60350 |
Heb je hulp nodig?
Als je hulp nodig hebt met EXSYS EX-60350 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd EXSYS
9 Juli 2026
8 Juli 2026
8 Juli 2026
8 Juli 2026
6 Mei 2026
12 Maart 2026
4 December 2025
1 December 2025
1 December 2025
29 November 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
7 Augustus 2026
7 Augustus 2026
7 Augustus 2026
7 Augustus 2026
6 Augustus 2026
6 Augustus 2026
6 Augustus 2026
6 Augustus 2026
6 Augustus 2026
6 Augustus 2026