IDEALLY INSTALL IN THE CENTRE OF CEILING
AT LEAST 300mm FROM LIGHT FITTINGS
LOCATE IONISATION ALARMS AWAY FROM
KITCHENS TO PREVENT NUISANCE ALARMS
ENSURE LIVE MAINS IS CORRECTLY
CONNECTED TO L TERMINALS ON ALL
INTERCONNECTED ALARMS - OTHERWISE
UNITS WILL BE DAMAGED
DO NOT FIT ACTUAL ALARM UNTIL ALL
BUILDING WORK IS COMPLETED TO AVOID
CONTAMINATION. AFTER CHECKING
OPERATION, COVER SMOKE ALARM WITH
DUST COVER UNTIL REQUIRED FOR USE
DISCONNECT THE ALARM BEFORE APPLYING
HIGH VOLTAGE INSULATION TESTS TO WIRING
DO NOT ATTEMPT TO OPEN THE ALARM AS
IT IS PERMANENTLY SEALED FOR SAFETY
DO NOT CONNECT ALTERNATIVE ENERGY
SOURCES e.g. WIND, SOLAR, UPS WITH
NON-SINUSOIDAL OUTPUTS
(see INSTALLATION section on page 10)