Eastron SDM320E Handleiding
Eastron
Meetapparatuur
SDM320E
Lees hieronder de 📖 handleiding in het Nederlandse voor Eastron SDM320E (4 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 6 personen en werd door 3.5 gebruikers gemiddeld met 4.9 sterren beoordeeld
Pagina 1/4

Eastron SDM3 E User Manual20
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086- - Fax: 0086- -573 83698881 83698882 573 83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastrongroup.com email:
sales@eastrongroup.com
SDM320E
Single-Phase 3 Wires Energy Meters
User Manual
2016 V1.2

Eastron SDM3 E User Manual20
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086- - Fax: 0086- -573 83698881 83698882 573 83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastrongroup.com email:
sales@eastrongroup.com
Applicaon
The SDM3 E “with a LCD screen for prefect reading”, are used to measure single-phase 3 wires application. The 20
meter measures acve energy meter (kWh) with a pulse output. The meter comply with IEC62053-21, IEC62052-11
standard.
General Specifications
Reference voltage,Un 110 /120 / 220V L-N
220 /240 / 380V L-L
Base Current (Ib) A 10
Max. Current (Imax) 100A
Mini Current (Imin) 0.5A
Starting current 0.4% of Ib
Power consumption <2W/10VA
Frequency 50/60Hz(±10%)
AC voltage withstand 4KV for 1 minute
Impulse voltage withstand 6KV-1.2uS wavform
Overcurrent withstand 30Imax for 0.01s
Pulse output rate 1600imp/kWh
Display LCD
Max. Reading 99999.99kWh
Acve energy Class 1 IEC62053- 21
Environment
Operang temperature - to +55 25℃ ℃
Storage and transportaon temperature - to +70 40℃ ℃
Reference temperature 23℃± ℃2
Relave humidity 0 to 95%, non-condensing
Altude up to 2500m
Warm up me s 10
Mechanical Environment M1
Electromagnec environment E2
Degree of pollution 2

Eastron SDM3 E User Manual20
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086- - Fax: 0086- -573 83698881 83698882 573 83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastrongroup.com email:
sales@eastrongroup.com
Pulse Output
The meter provides a pulse output, which is passive type. The constant is 1600imp/kWh.
ATTENTION: Pulse output must be fed as shown in the wring diagram below.
Scrupulously respect polaries and the connecon mode.
Opto-coupler with potenal-free SPST-NO Contact
Contact range: 5~27VDC Max. current Input: 27mA DC
Mechanics
Din rail dimensions (WxHxD) DIN 43880 76x100x66
Mounting DIN rail 35mm
Sealing IP51 (indoor)
Material self-extinguishing UL94V-0
SDM3 E display20
Product specificaties
Merk: | Eastron |
Categorie: | Meetapparatuur |
Model: | SDM320E |
Heb je hulp nodig?
Als je hulp nodig hebt met Eastron SDM320E stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Eastron

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025

23 Mei 2025
Handleiding Meetapparatuur
- Meetapparatuur Bresser
- Meetapparatuur Technics
- Meetapparatuur Beurer
- Meetapparatuur Wentronic
- Meetapparatuur IHealth
- Meetapparatuur Grundfos
- Meetapparatuur KS Tools
- Meetapparatuur Soehnle
- Meetapparatuur Kübler
- Meetapparatuur LabNation
- Meetapparatuur Adwa
- Meetapparatuur MASIMO
- Meetapparatuur Nedis
- Meetapparatuur Logilink
- Meetapparatuur Elgato
Nieuwste handleidingen voor Meetapparatuur

2 Juni 2025

2 Juni 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025