Eastron SDM3 E User Manual20
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086- - Fax: 0086- -573 83698881 83698882 573 83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastrongroup.com email:
sales@eastrongroup.com
SDM320E
Single-Phase 3 Wires Energy Meters
User Manual
2016 V1.2
Eastron SDM3 E User Manual20
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086- - Fax: 0086- -573 83698881 83698882 573 83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastrongroup.com email:
sales@eastrongroup.com
Applicaon
The SDM3 E “with a LCD screen for prefect reading”, are used to measure single-phase 3 wires application. The 20
meter measures acve energy meter (kWh) with a pulse output. The meter comply with IEC62053-21, IEC62052-11
standard.
General Specifications
Reference voltage,Un 110 /120 / 220V L-N
220 /240 / 380V L-L
Base Current (Ib) A 10
Max. Current (Imax) 100A
Mini Current (Imin) 0.5A
Starting current 0.4% of Ib
Power consumption <2W/10VA
Frequency 50/60Hz(±10%)
AC voltage withstand 4KV for 1 minute
Impulse voltage withstand 6KV-1.2uS wavform
Overcurrent withstand 30Imax for 0.01s
Pulse output rate 1600imp/kWh
Display LCD
Max. Reading 99999.99kWh
Acve energy Class 1 IEC62053- 21
Environment
Operang temperature - to +55 25
Storage and transportaon temperature - to +70 40
Reference temperature 23℃± 2
Relave humidity 0 to 95%, non-condensing
Altude up to 2500m
Warm up me s 10
Mechanical Environment M1
Electromagnec environment E2
Degree of pollution 2
Eastron SDM3 E User Manual20
Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: 0086- - Fax: 0086- -573 83698881 83698882 573 83698883
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. Web: www.eastrongroup.com email:
sales@eastrongroup.com
Pulse Output
The meter provides a pulse output, which is passive type. The constant is 1600imp/kWh.
ATTENTION: Pulse output must be fed as shown in the wring diagram below.
Scrupulously respect polaries and the connecon mode.
Opto-coupler with potenal-free SPST-NO Contact
Contact range: 5~27VDC Max. current Input: 27mA DC
Mechanics
Din rail dimensions (WxHxD) DIN 43880 76x100x66
Mounting DIN rail 35mm
Sealing IP51 (indoor)