DSC PG9872 Handleiding
DSC Bewegingsdetector PG9872
Bekijk gratis de handleiding van DSC PG9872 (5 pagina’s), behorend tot de categorie Bewegingsdetector. Deze gids werd als nuttig beoordeeld door 62 mensen en kreeg gemiddeld 4.2 sterren uit 2 reviews. Heb je een vraag over DSC PG9872 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/5

PGx872 Wirelessceiling PIR presence/security detector Installation Instructions©2018 Tyco Security Products,Toronto,Canadawww.dsc.com Tech.Support:1-800-387-36301
D-307204
PG9872/PG8872/PG4872 Overview
ThePGx872is asmartwirelessceiling PIRpresence/securitydetector
(selectedmode)thatcreatesa 360°coveragearea todetectthemove-
ment ofintrudersinindoor areas.
Thedetectorhas thefollowingfeatures:
lPresencedetection mode -active 15 minutes afterinstallation
(power-up)andthenonly when thepanel is in Disarm mode.
lSecurity detection mode- operatesas anormal motion security
detector.
lBuilt-inlinkqualityindicatorseliminate the need for theinstaller to
physicallyapproach thecontrol paneland reduceinstallationtime.
lThedevicesupportstemperatureand lightlevel reportsto com-
patible alarmsystemsthat supporttemperatureandlight sensors.
lTamper protection.
lPowerG two-way Frequency Hopping Spread SpectrumFHSS-
TDMA technology.
lTheAdvancedTrueMotion Recognition™algorithm (patented)dis-
tinguishesbetween the truemotion ofanintruderandany other dis-
turbances whichmay causefalsealarms.
NOTE: ForUL installations,thedetectorisforuse withUL listed con-
trol unitsonly.
Legend
A
B
C
D
E
A
B
C
D
E
LEDs
Light sensor
Battery
Tamper protection
Pyro sensor
Figure 1.Internalview
Insertingorreplacingthe battery
To insert thebattery, completethe following steps.
1.To separatethedetector fromthemounting bracket, rotate the
bracketanticlockwiseandpull it from thedetector.
2.Insertthe battery while observingpolarity.
NOTE: If thebatteryisalready installed, pullthe isolation strip
thatprotrudes fromthe backofthe detector.
3.Align the brackettabswith the detector slots and rotate the detector
clockwisetoverify that it is securely attached.
Figure 2.Removingthebracket
NOTE: Ifascrewisusedto securethe detectortothe bracket(see
Figure3), openthescrewcover, andremovethescrew. Toseparate
the detectorfromthemountingbracket,ensurethe screwcover is
fullyopenorfully closed,and rotatethedetectoranticlockwise.
Replacethe batteryensuringpolarityisobserved.Replace the
detector andsecuretothebracketwiththescrew.
NOTE: Itisrecommended to wait about1 minuteafterbattery
removal be foreinsertingthenewbattery.
Caution! Riskof explosionifbatteryisreplaced byan incorrect type.
Dispose ofused batteriesaccordingto themanufacturer'sinstructions
and accordingto localrules andregulations.
Enrollment
Refertothepanel installationmanua l forthee nrollmentprocedure.
A general descriptionofthe procedureisprovidedinthe following
flow chart:
Step Procedure
1See theinstallationmanualforthe alarm systemthatthe
device isbeing enrolled on toensure thatthe propersteps
are used.
2Enter theDevice Enrollment optionthroughthe specified
methodandselectthe appropriateoptiontoaddthe new
device.
3Enrollthe deviceby eitherinsertingthe batterytopower on
thedeviceuntil theenrollmentisdetected,orbyenteringthe
Device ID.
Pulltheenrollmenttab orinsertthebatteryto powerup the
deviceandbegin theauto-enrollmentprocess.
NOTE: ID:XXX-XXXXYou canalso enter(thenumber of
the devicethatisprinted onthe label),if thedevicedoes not
automatically enroll.
4Selectthe desiredZone Number.
5Configureanydevice parametersthatare required.
6Mount andtest thedetector.SeeWalk testing/ localdia-
gnostic testingforinformation ontestingthedevice.In addi-
tion,seethe alarmsysteminstallationmanualthatthe device
isenrolledonforothertestproceduresthat arerequired.
NOTE: Ifthedetectoris alreadyenrolled,youcan configurethe
detectorparametersbyprogrammingthe system.See thealarmsystem
installationmanualformore informationaboutdevice parameters.
NOTE: Whenenrolling the PGx972 detectortowireless panels
(WP80XX)with version 19.4orlower, thedetectorwillbeenrolled as
motiondetector, ID120-xxxx,andlabelled ‘Motion Sens’inthe panel.
Installation tips
Usethe followingasa guide forlocatingasuitablemountinglocation.
Figure 3.Generalguidelines
1.Keepawayfrom heatsources.
2.Donot exposetoairdrafts.
3.Donot install outdoors.
4.Avoiddirect sunshine.
5.Do notinstallnear high voltageelectricallines.
6.Donot install behind partitions.
7.Mount onasolidstablesurface.
WARNING! Donot partially orcompletelyobscurethedetector’s
field ofview.
WARNING!TocomplywithFCC andISEDCanadaRF exposurecom-
pliancerequirements,the PIRdetectorshould be located at a distance
ofatleast20 cm fromall personsduringnormal operation.Theanten-
nasusedfor thisproductmustnotbeco-locatedor operatedincon-
junction withanyotherantennaortransmitter.
NOTE: ThePGx872 W irelessceilingPIRpresence/security detector
shall beinstalledandusedwithinanenvironmentthat providesthe
pollutiondegree max2 and overvoltagescategoryIIin NON
HAZARDOUSLOCATIONS.Theequipmentisdesigned tobe
installedonly byqualifiedservice persons.
NOTE: PGx872shallbeinstalledin accordancewiththeStandardfor
Installation and Classificationof ResidentialBurglarAlarm Systems,
UL 1641.
Walktesting/localdiagnostic testing
Beforepermanentlymountingany wirelessdevice,temporarily mount
the deviceand performa walktest. Perform awalktestofthe cov-
eragearea atleastonceaweektoensure thatthe detectorisworking
correctly.
After insertingthebattery orclosing thebracket,thedetectorwillauto-
matically enter a stabilityperiodwherethe LED flashes REDfor 90
seconds.Walktest thecoveragearea; theLED lightsred eachtime
your motionisdetectedfollowedby 3LEDblinks.Thecolorof the 3
LED blinksindicatethe received signal strength.In walk-test mode,
regardlessoftheLEDSelectionstatus,theLED lightsuponevery
motion detection.After15minutesthedetectorautomaticallyenters
normal mode.
Thefollowingtableindicates the received signal strength.
LED ResponseSignal Strength
3greenLEDblinks STRONG
3 orangeLEDblinksGOOD
3red LEDblinksPOOR
No blinksNo communication
IMPORTANT! Only GOODorSTRONGsignal strengthsareaccept-
able.Ifyourece iveaPOOR signalfromthedevice,re-locateitand
re-test untilaGOODorSTRONGsignal isreceived.
NOTE: ForUL/ULC installations,onlySTRONGsignalleve lsare
acceptable.Afterinstallation verify the productfunctionalityincon-
junctionwiththecompatibledevices HSM2HOST9,HS2LCDRF(P) 9,
HS2ICNRF(P)9, PG9920, WS900-19,andWS900-29.
NOTE: Fordetailed Placement instructionsrefertothe control panel
reference manual.
Walk-testthe coveragearea bywalkingacrossthefar end ofthe cov-
eragepattern inboth directions.The red LEDlights eachtimeyour
motion isdetected followedbyasteadyLEDsignalstrengthindication.
Mountingthe device
1.Mark and drilltwo holesinthemounting surface.Ifyouinstall
tamper protectionon the detector, mark and drillonehole for the
tamper protection andoneholefor oneofthe other available slots.
2.Fastenthe brackettothemountingsurface withthe twoscrews.
3.Align the brackettabswith the detector slots and rotate the detector
clockwise.Verify that it is securelyattached.
4.Fastenthe detectortothe bracketwiththescrew.
A
B
Figure4.Fastening thebracket
D
E
C
Figure5. Attaching thedetector
Figure6.Fastening thedetector
ATamper protection
BBracket screw slots
CIsolation strip
DBracket tabs
EDetector slots
Thefollowingtable outlinesthe detectiondistance inrelationtothe
mounting height.
Height 2 m
6.6 ft
3 m
9.8 ft
4 m
13.1 ft
5 m
16.4 ft
6 m
19.7 ft
Radius detec tiondistance3.1 m
10.2 ft
3.75 m
12.3 ft
4.5 m
14.8 ft
6.5 m
21.3 ft
10 m
32.8 ft
LED Operation
LED IndicationsEvent
Red LED blinksStabilization (warm-up 90 seconds)
RedLEDon0.2 secondsTamper open/close
RedLEDon2 secondsIntruderalarm
Temperature display
For instructionsondisplaying thetemperature ofzoneson thecontrol
pane l asmeasuredbythePGx872,refertothepanelinstallationguide.
Specifications
General
Detector Type
Four pyroelectric sensorsoperating in adualseparated configuration
Optical
Lens data
Fresnel typelens.
Numberofbeams: 120
Max. coverage
20 m/360° atthemaximum installation heightof 6m(19.7 ft)
Figure 7.Beam distributionat 2.7m (8.9ft)
Figure 8.Beam distributionat 6m (19.7ft)
Electrical
Power supply
Product specificaties
| Merk: | DSC |
| Categorie: | Bewegingsdetector |
| Model: | PG9872 |
| Kleur van het product: | Wit |
| Gewicht: | 110 g |
| Breedte: | 150 mm |
| Diepte: | 150 mm |
| Plaatsing: | Binnen |
| Connectiviteitstechnologie: | Draadloos |
| Montagewijze: | Plafond |
| Type stroombron: | Batterij/Accu |
| Levensduur batterij/accu: | 3 jaar |
| Ingangsspanning: | 3 V |
| Frequentie: | 915, 433, 868 MHz |
| Bedrijfstemperatuur (T-T): | -10 - 50 °C |
| Batterijtechnologie: | Lithium |
| Type batterij: | CR123A |
| Detectieafstand: | 20 m |
Heb je hulp nodig?
Als je hulp nodig hebt met DSC PG9872 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Bewegingsdetector DSC
30 Maart 2023
29 Maart 2023
27 Maart 2023
20 Maart 2023
7 Maart 2023
21 Februari 2023
11 Februari 2023
7 Februari 2023
Handleiding Bewegingsdetector
Nieuwste handleidingen voor Bewegingsdetector
7 Januari 2026
4 Januari 2026
28 December 2025
25 December 2025
25 December 2025
25 December 2025
25 December 2025
23 December 2025
22 December 2025
21 December 2025