Busch-Jaeger 220 MasterLINE premium Handleiding

Busch-Jaeger Bewegingsdetector 220 MasterLINE premium

Lees hieronder de 📖 handleiding in het Nederlandse voor Busch-Jaeger 220 MasterLINE premium (22 pagina's) in de categorie Bewegingsdetector. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/22
1
473-1-8104 │ Rev. 01 │ 11. 2012
O
perating Instructions
Busch-Wächter®
Pos: 2 /#Neustruktur#/ Online-Dokumentati on (+KNX)/Titelbl ätter/Waechter /6848 - 220 MasterLINE premiu m @ 28\mod_134701011559 1_15.docx @ 232302 @ @ 1
6848 AGM-…
220 MasterLINE premium
=== Ende der Liste für Textmarke Cover ===
Operating Instructions
Busch-Wächter®
Operating Instructions | 1473-1-8104 — 2 —
Pos: 4 /#Neustruktur#/ Online-Dokument ation (+KNX)/Inhal tsverzeichnis (- -> Für alle Dokumente <-- )/Inhaltsverzeichni s @ 19\mod_1320649044386_ 15.docx @ 109653 @ @ 1
1 Safety ....................................................................................................................................................................... 3
2 Intended use ............................................................................................................................................................ 3
3 Environment ............................................................................................................................................................. 3
4 Setup and function ................................................................................................................................................... 4
4.1 Features of function and equipment ........................................................................................................ 4
4.2 Detection ranges ..................................................................................................................................... 5
4.2.1 Overview of the detection ranges ............................................................................................................ 5
4.2.1.1 Standard coverage .................................................................................................................................. 5
4.2.1.2 Coverage with zone separation ............................................................................................................... 5
4.2.2 detection Limitation of the range ............................................................................................................. 5
5 Technical data.......................................................................................................................................................... 6
6 Installation and electrical connection ....................................................................................................................... 7
6.1 Requirements for the electrician ............................................................................................................. 7
6.2 Mounting ................................................................................................................................................. 8
6.2.1 Mounting methods .................................................................................................................................. 8
6.2.1.1 Wall mounting ......................................................................................................................................... 8
6.2.1.2 Wall mounting with gradient. ................................................................................................................... 9
6.2.1.3 Ceiling mounting ..................................................................................................................................... 9
6.2.1.4 Corner mounting ..................................................................................................................................... 9
6.2.2 Installation sites .................................................................................................................................... 10
6.2.3 Preparing the installation ....................................................................................................................... 10
6.2.4 Water drainage ..................................................................................................................................... 11
6.2.5 Mounting steps ...................................................................................................................................... 12
6.3 Electrical connection ............................................................................................................................. 14
6.3.1 Standard connection ............................................................................................................................. 14
6.3.2 Standard connection with external signal generators ............................................................................ 14
6.3.3 Standard connection with 2 circuit breakers per relay 10 A .................................................................. 14
7 Commissioning ...................................................................................................................................................... 15
7.1 Setting / limiting the coverage and the detection range ......................................................................... 15
7.2 Activation test ........................................................................................................................................ 16
8 Operation ............................................................................................................................................................... 17
8.1 Control elements ................................................................................................................................... 17
8.2 Standard operation ............................................................................................................................... 17
8.3 Standard operation (time- and brightness dependent) .......................................................................... 18
8.4 Auxiliary post operation ......................................................................................................................... 18
8.4.1 Operation with extension unit push-button ............................................................................................ 18
9 Remote control ....................................................................................................................................................... 19
9.1 Control elements of the remote control ................................................................................................. 19
9.2 Technical data of the remote control ..................................................................................................... 19
9.3 Commissioning of remote control .......................................................................................................... 20
9.4 Battery change of remote control .......................................................................................................... 20
=== Ende der Liste für Textmarke TOC ===
Operating Instructions
Busch-Wächter®
Safety
Operating Instructions | 1473-1-8104 — 3 —
Pos: 6 / #Neustruk tur#/Online-Dokumentati on (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1 302612791790_15.doc x @ 103357 @ 1 @ 1
1 Safety
Pos: 7 / #Neustruk tur#/Online-Dokumentati on (+KNX)/Si cherhei tshinweise un d Hinwei se (--> Für al le Dokumente <--)/Warnhi nweise/Sicherheit - 230 V @ 18\mod_1302 606816750_15.doc x @ 103308 @ @ 1
Warnin
g
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
– Work on the 230V supply system may only be performed by authorised electricians!
– Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 8 / #Neustruk tur#/Online-Dokumentati on (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bestimmungsgemäßer Gebrauch @ 18\mod_130276332 1316_15.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /#Neustruktur#/ Onli ne-Dokument ation (+KNX)/Besti mmungsgemäßer Gebrauc h (--> Für alle Dokumente <- -)/Busch-Dimmer/B estimmungsgemäßer Gebr auch @ 23\mod_13353504498 57_15.docx @ 208763 @ @ 1
The device is to be used exclusively with the components that are supplied and licensed as described in chapter
"Setup and function".
Pos: 10.1 /#Neustrukt ur#/Modul-Strukt ur/Onli ne-Dokumen tation/Überschr iften (--> Für all e Dokume nte <--)/1. Ebene/ U - Z/Umwelt @ 18\mod_1302614158 967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 10. 2 /#Neust ruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise un d Hinwei se (--> Für al le Dokumente <--)/Hinwei se/Hi nweis - Umwelt - Hin weis Elektrogeräte @ 18\mod _1302763973434_15.doc x @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
– The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos: 10. 3 /#Neust ruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise un d Hinwei se (--> Für al le Dokumente <--)/Hinwei se/Hi nweis - Umwelt - Entsor gung Elektrogeräte @ 20\mod_1325760695972_ 15.docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the
packaging material and electric devices and their components via the authorized collecting depots and disposal
companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and
the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos: 11 /#Neustruk tur#/Online-Dokumentati on (+KNX)/Ste uermodule - On line-Dokumentation (--> Für all e Dokume nte <--)/++++++++++++ Seitenumbruch +++ +++++++++ @ 9\mod_126889866 8093_0.docx @ 52149 @ @ 1


Product specificaties

Merk: Busch-Jaeger
Categorie: Bewegingsdetector
Model: 220 MasterLINE premium
Kleur van het product: Bruin
Breedte: 125 mm
Diepte: 141 mm
Hoogte: 115 mm
Gebruikershandleiding: Ja
Internationale veiligheidscode (IP): IP55
Plaatsing: Indoor, Outdoor
Connectiviteitstechnologie: Bedraad
Montagewijze: Muur
Type stroombron: AC
Waterdicht: Ja
Type beeldsensor: Infraroodsensor
Ingangsspanning: 230 V
Frequentie: 50/60 Hz
Stroomverbruik (typisch): 1 W
Bedrijfstemperatuur (T-T): -25 - 55 °C
Detectie hoek: 220 °
Detectieafstand: 16 m
Installatie hoogte (max): 2.5 m
Lichtgevoeligheid: 300 Lux

Heb je hulp nodig?

Als je hulp nodig hebt met Busch-Jaeger 220 MasterLINE premium stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Bewegingsdetector Busch-Jaeger

Handleiding Bewegingsdetector

Nieuwste handleidingen voor Bewegingsdetector