AMX RDA-ENC6B Handleiding
AMX Niet gecategoriseerd RDA-ENC6B
Bekijk gratis de handleiding van AMX RDA-ENC6B (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 88 mensen. Heb je een vraag over AMX RDA-ENC6B of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

QUICK START GUIDE
RDA-ENC6B Radia 6-Space Enclosure with 6 Breakers
Overview
The RDA-ENC6B (FG606-13) enclosure provides secure mounting for AMX Lighting and
ProLink controllers, and lighting modules. These enclosures contain circuit breakers.
They also provide 18 knockouts for 1/2", 3/4", and 1" conduits. They include circuit
breakers and terminals for multi-phase wiring.
These enclosures are CE, UL, and C-UL approved.
Installation Instructions:
•For indoor use only.
•Mount on vertical surface only.
•Maintain 12" (304.88 mm) minimum clearance above and below the enclosure.
•Route class 1 conductors through upper conduit knockouts.
•Route class 2 conductors through lower conduit knockouts.
•Use 75°C (167°F) copper conductors only.
•Install filler plate #28-10500 (RDA-EFP) in all unused openings.
•Install only UL approved modules (see the UL Number Cross Reference to AMX
Lighting ID table).
Enclosure Weights:
•RDA-ENC6B: 16.5 lbs. (7.48 kg)
Dimensions between center lines (from FIG. 2):
RDA-ENC6B:
•A to B = 16.0" (406.4 mm)
•B to C = 22.88" (581.2 mm)
Radia enclosures must be mounted on a vertical surface with a minimum of 12"
(304.8 mm) clearance above and below the enclosure.
Specif ications
•Maximum input wire #1/0 AWG (50mm²)
•Maximum line input is 120 A (per terminal)
•Torque input wire to 44 in-lbs. (5.0 N/m)
•Wire stripping length: 0.67 inches (17 mm)
•Input 1 feeds channels 1, 4, 7, and 10
•Input 2a feeds channels 5 and 11
•Input 2b feeds channels 2 and 8
•Input 3 feeds channels 3, 6, 9, and 12
•Breakers are UL 489 listed 10,000 AIC, 100% Switching Duty, Hydraulic-
Magnetic
The following table cross references the UL ID module numbers and AMX Lighting
module IDs. The modules identified are the only ones that can be used in the RDA-
ENC6B enclosures.
FIG. 1 TOP, FRONT, BOTTOM, AND SIDE VIEWS OF THE RDA-ENC6B ENCLOSURES
TOP VIEW
SIDE VIEW
RDA-ENC6B
24.0"
(610 mm)
18.0"
(457.2 mm)
0.75"
(19.05 mm)
6.0"
(152.4 mm)
RDA-ENC6B Configurations:
- ENC6B/120 20 A Breakers
- ENC6B/240 10 A Breakers
BOTTOM VIEW
Note:
LINE INPUTS: 120 A MAX PER TERMINAL
Use 75° C copper conductors only.
Torque terminals to 44 in-lbs.
(610 mm)
24.0"
FIG. 2 BRACKET CONFIGURATION
UL NUMBER CROSS REFERENCE TO AMX LIGHTING ID
UL IDAMX ID
28-10140 RDD-DM6/120
28-10150 RDD-DM6/240
28-10160 RDD-DM6/277
28-10170 RDA-PSM/120
28-10200 RDM-INC
28-10210 RDM-2INC
28-10260 RDM-3SWM
28-10350 RDM-2FDB
28-10370RDM-DC,
RDM-2DC,
RDM-3DC
A to B
B to C
Bottom slot
Top slot
Configuration for
right and left
mounting brackets
for all Radia
enclosures.
Maximum mounting
screw size: #12
Product specificaties
| Merk: | AMX |
| Categorie: | Niet gecategoriseerd |
| Model: | RDA-ENC6B |
| Kleur van het product: | Zwart |
| Gewicht: | 7500 g |
| Breedte: | 457 mm |
| Diepte: | 152 mm |
| Hoogte: | 607 mm |
| Stroom (max.): | 140 A |
Heb je hulp nodig?
Als je hulp nodig hebt met AMX RDA-ENC6B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd AMX
8 Juli 2026
7 Juli 2026
6 Juli 2026
10 Mei 2026
7 Mei 2026
5 Mei 2026
4 Mei 2026
24 November 2025
5 Augustus 2025
5 Augustus 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
16 September 2026
16 September 2026
16 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026