ABB US/U 12.2 Handleiding


Bekijk gratis de handleiding van ABB US/U 12.2 (90 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 278 mensen en kreeg gemiddeld 5.0 sterren uit 139.5 reviews. Heb je een vraag over ABB US/U 12.2 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/90
Product Manual
ABB i-bus
KNX
Intelligent Installation Systems
Universal Interface
US/U 12.2
ABB i
-bus KNX
US/U 12.2, Universal Interface, 2
- fold, FM
© 2012 ABB STOTZ- 1KONTAKT GmbH
Page
1 General ................................................................................................. 3
1.1 Product and functional overview ........................................................... 3
2 Device technology .............................................................................. 5
2.1 ....................................................................................... Technical data 5
2.2 Circuit diagram ...................................................................................... 7
2.3 Dimension drawing ............................................................................... 8
2.4 Assembly and installation ..................................................................... 8
2.5 Description of the inputs and outputs ................................................... 9
3 Commissioning................................................................................. 10
3.1 Overview ............................................................................................. 10
3.2 Parameters and communication objects ............................................ 12
3.2.1 General parameters ......................................................................... 12
3.2.2 Operating mode “Switch sensor” ...................................................... 16
3.2.3 Operating mode “Switch/Dimming sensor” ...................................... 23
3.2.4 Operating mode “Shutter Sensor” .................................................... 28
3.2.5 Operating mode “Value / forced operation” ...................................... 33
3.2.6 Operating mode “Control scene” ...................................................... 38
3.2.7 Operating mode “Control valve drive” .............................................. 48
3.2.8 Operating mode “Control LED” ........................................................ 56
3.2.9 Operation mode “Switching sequence” ............................................ 61
3.2.10 Operation mode “Multiple operation” ............................................... 66
3.3 Programming ...................................................................................... 69
4 Special functions.............................................................................. 70
4.1 Debounce time and minimum signal time ........................................... 70
4.2 Reaction on bus voltage failure .......................................................... 71
4.3 Reaction after bus voltage recovery ................................................... 71
5 Application examples....................................................................... 72
5.1 1 button operation with central function .............................................. 72
5.2 Operation of dimmable illumination .................................................... 74
5.3 Operation of shutters .......................................................................... 76
5.4 Control of scenes ................................................................................ 78
5.5 Control of a heater valve ..................................................................... 81
5.6 Switching of lighting in switching sequence ........................................ 83
5.7 Switching of lighting via multiple button pushes ................................. 85
6 Appendix ............................................................................................ 87
6.1 Switching sequence “All combinations” .............................................. 87
6.2 Value table for object “8 Bit scene” ..................................................... 88
6.3 Ordering information ........................................................................... 88
ABB i
-bus KNX
US/U 12.2, Universal Interface, 2
- fold, FM
© 2012 ABB STOTZ- 2KONTAKT GmbH
This manual describes the function of the Universal Interface US/U 12.2 with its
application program
Binary Input Display Heat 12f/1.
Subject to
changes and errors excepted.
Exclusion of liability:
Despite checking that the contents of this document match the hardware and
software, deviations cannot be completely excluded. We therefore cannot accept any
liability for this. Any necessary correcti
ons will be incorporated in new versions of the
manual.
Please inform us of any suggested improvements.


Product specificaties

Merk: ABB
Categorie: Niet gecategoriseerd
Model: US/U 12.2
Gewicht: 68 g
Breedte: 54 mm
Diepte: 54 mm
Hoogte: 19 mm
Gewicht verpakking: 80 g
Breedte verpakking: 92 mm
Diepte verpakking: 23 mm
Hoogte verpakking: 65 mm
Certificering: IP20
Duurzaamheidscertificaten: RoHS, WEEE
Naleving van duurzaamheid: Ja
Aantal kanalen: 12 kanalen
Module type: Analoog
Signaal directie: Invoer/uitvoer

Heb je hulp nodig?

Als je hulp nodig hebt met ABB US/U 12.2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden