Bekijk gratis de handleiding van Enda EC2401 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.0 sterren uit 2 reviews. Heb je een vraag over Enda EC2401 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

Note :
1) Panel thickness should
be maximum 7mm.
2) If there is no 60mm free
space at the back side of
the device, it would be
difficult to remove it from
the panel.
NOTE :
90-250V AC
or
10-30V DC/
8-24V AC
50/60Hz 5VA
Supply
UV/LV
ENDA EC2401 UP / DOWN COUNTER
1
2
61mm 5mm
Panel
77mm
35mm
90-250V AC 50/60Hz ;10-30V DC/ 8-24V AC SMPS
EN 61326-1: 2013
± %0.01
EC2401
SET
EC2401
SET
123456
789
10
ENDAINDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EC2401-UV
UP /DOWN COUNTER
90-250V AC
50/60Hz
+12V
11
12
8680407726448
Made in Turkey
SENSOR INP
GND
123456
789
10
1112
GND
SENSOR_INP
+ 12V
MECHANIC SWITCH
6
789
10
1112
12
GND
SENSOR_INP
+ 12V
90-250V AC
50/60Hz 5VA
12345
PNP PROXIMITY SWITCH
71,5mm
28,5mm
1
2
ENDA EC2401is intended for installation in control panels. Make sure that the device is used only for intended
purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant
locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make
sure that the operation temperature is not exceeded. The cables should not be close to the power cables or
components.
ELECTRICAL CHARACTERISTICS
Max. 5VA
2.5mm² screw-terminal connections
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II ).
Max.2000m
80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.
0 ... +50°C/-25 ... +70°C (with no icing)
According to EN 60529 ; Front Panel : IP65,
Rear Panel : IP20
Supply
Power Consumption
Wiring
Accuracy
EMC
Safety Requirements
ENVIRONMENTAL CONDITIONS
Height
Ambient / Storage Temperature
Relative Humidity
Protection Class
Scale
OUTPUT
CONNECTION SAMPLES
KEEP AWAY device from exposed to corrosive, volatile and flammable gases
or liquids and DO NOT USE the device in similar hazardous locations.
Avoid any liquid contact when the device is switched on.
DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents.
35x77 Sized.
Easy to use.
Input frequency selection.
Selectable parameter security..
CE Marked according to European Norms.
Note :
1)Mains supply cords shall meet the requirements of IEC 60227
or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrurment
and it should be easily accessible by the operator.
SUPPLY :
Line
Neutral
Switch
Fuse
F 100 mA
250V AC
Cable size: 1,5mm²
Fuse should be
connected.
Equipment is protected throughout
by DOUBLE INSULATION.
Holding screw 0.4-0.5Nm
4 Digits, 12.5mm, 7 Segment Red Display LED (V2 Code : Blue Display).
INPUTS
Sensor Input
Measurement Frequency
Measures frequencies between 0.07Hz and 10000Hz.
5 to 30V pulses
Sensor Supply Output
12V DC, Max. 30mA (unregulated)
1
2
Read this document carefully before using this device. The guarantee will be expired by damaging
of the device if you don't attend to the directions in the user manual. Also we don't accept any
compensations for personal injury, material damage or capital disadvantages.
Thank you for choosing ENDA EC2401Up / Down Counter devices.
HOUSING
Housing Type
Dimensions
Weight
Enclosure Material
Suitable for flush-panel mounting.
W77xH35xD61mm
Approx. 190g (after packing the device )
Self extinguishing plastics
DIMENSIONS
Flush
mounting
clamp
Panel Cut-out
To removing mounting clamps :
- Push the flush-mounting clamps
indirection asshown in the
figure.
-And, pull out the clamp in
direction
Depth
Rubber
packing
Note :
The NPN PROXIMITY SWITCH connection is applicable as same as PNP PROXIMITY SWITCH.
Flush
mounting
clamp
123456
789
10
ENDAINDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EC2401-UV
UP /DOWN COUNTER
90-250V AC
50/60Hz
+12V
11
12
8680407726394
Made in Turkey
SENSOR INP
GND
123456
789
10
ENDAINDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EC2401-LV
UP /DOWN COUNTER
10-30V DC / 8-24V AC
50/60Hz
+12V
11
12
8680407726448
Made in Turkey
SENSOR INP
GND
90-250V AC
50/60Hz 5VA
Order Code : EC2401
1 - Supply Voltage
UV......90-250V AC
LV.......10-30V DC /
8-24V AC
1
english
Up to date: 23.11.2022, modification reserved and can be change any time previous notice !
1. /2
EC2401-EN-23112022
E-mail : [email protected]
Internet : www.suran-elektronik.de
Tel.: +49 (0)7852 / 4889 962
SURANIndustrieelektronik
An der Hanfrötze 6 / D-77731 Willstätt
Product specificaties
| Merk: | Enda |
| Categorie: | Niet gecategoriseerd |
| Model: | EC2401 |
Heb je hulp nodig?
Als je hulp nodig hebt met Enda EC2401 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Enda
9 Maart 2026
9 Maart 2026
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026