Bekijk gratis de handleiding van Uline H-11042 (6 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.9 sterren uit 3 reviews. Heb je een vraag over Uline H-11042 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/6
PAGE 1 OF 6 0125 IH-11042
1-800-295-5510
uline.com
H2FLOW
EYEWASH STATION
H-11042
SAFETY
WARNING! Failure to comply with these
instructions may result in serious personal injury,
serious illness, blindness or death.
The H2Flow must be level for proper operation.
The unit may weigh over 110 lbs. when filled
with solution. Assistance may be required when
installing unit on the mounting bracket.
Employees must be instructed in the use of
emergency eyewash stations.
This unit is intended for emergency use by victims
of eye contamination until medical treatment
is obtained. In all cases, the victim should seek
medical attention immediately after flushing.
An individual or department must be assigned the
task of checking all self-contained eyewash units
on a weekly basis.
The use of water preservative is recommended
with this eyewash station to prevent the growth of
harmful bacteria in the eyewash tank.
Use of a fluid beyond the expiration date may
result in serious personal injury.
INSTALLATION
LOCATION
The ANSI Standard Z358.1-2014 requires that:
1. The H2Flow should be positioned with the nozzle(s)
no less than 33" and no greater than 45" from
the floor and 6" minimum from the wall or nearest
obstruction.
2. Eyewash units should be in accessible locations
that require no more than 10 seconds to reach. The
eyewash should be located on the same level as
the hazard, and the path of travel should be free of
obstructions that may inhibit the immediate use of
the equipment. For a strong acid or a strong caustic,
the eyewash should be immediately adjacent to the
hazard.
3. Each eyewash location should be identified with a
highly visible sign positioned so the sign is visible
within the area served by the eyewash. The area
around the eyewash should be well-lit.
4. The eyewash station must be installed in an easily
accessible location in the immediate area of
hazard to the employee.
The H2Flow may be placed on any level surface of
required height, such as a table or bench. Allow for
proper drainage and disposal of the flushing solution.
The unit may also be mounted on a wall or post using
the metal mounting bracket. The unit must be level for
proper operation.
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.

Beoordeel deze handleiding

4.9/5 (3 Beoordelingen)

Product specificaties

Merk: Uline
Categorie: Niet gecategoriseerd
Model: H-11042

Heb je hulp nodig?

Als je hulp nodig hebt met Uline H-11042 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden